Document Audience: | INTERNAL |
Document ID: | A0115-1 |
Title: | 350Watt Power Supply experiencing slightly higher than desired failure rate. |
Copyright Notice: | Copyright © 2005 Sun Microsystems, Inc. All Rights Reserved |
Update Date: | Mon Dec 15 00:00:00 MST 1997 |
---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------
FIELD CHANGE ORDER
(For Authorized Distribution by SunService)
FCO #: A0115-1
Status: inactive
Synopsis: 350Watt Power Supply experiencing slightly higher than desired failure rate.Date: Dec/15/97
Keywords:
350Watt Power Supply experiencing slightly higher than desired failure rate
Product Category: Desktop / Power
Product Affected:
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
SMC-A14 Ultra 2 2170 SMC500 Media Server -
A14 Ultra 2 ALL Ultra Enterprise 2 -
Netra-I Ultra 2 2/1300 Netra I Server -
Netra-J Ultra 2 2/1300 Netra J Server -
Parts Affected:
Part Number Description
----------- -----------
300-1315-01 Power Supply, 350Watt, A14, Ultra 2
Type Vendor Model SerialNumber(Min) SerialNumber(Max) Firmware
---- ------ ------- ------------------ ------------------ --------
n/a
References:
ECO# WO_10986
ECO# WO_10788
LEAP# 802
PA# 2524
Issue Description:
In order to improve return rates on the Ultra 2 350Watt Power Supply
(p/n 501-1315-01) a new part number (p/n 501-1342-01) has been released
incorporating several product quality improvements. Some of the failure
symptoms that these improvements address are;
1. Fan may contact internal parts causing fan noise.
2. Power supply may fail with no outputs.
3. Floppy drive may have read errors because of a "common mode noise" problem
caused by the PCB layout in the power supply.
The Ultra 2 350W Power Supply is still a good quality power supply and will
continue to be used in the SunService Logistics inventory since there is no
need to purge it. Only under the special circumstances, as listed under
SPECIAL CONSIDERATIONS, should the new power supply (p/n 501-1342-01) be
ordered.
Implementation:
---
| | MANDATORY (Fully Pro-Active)
---
---
| | CONTROLLED PRO-ACTIVE (per Sun Geo Plan)
---
---
| X | UPON FAILURE
---
Replacement Time Estimate:
30 minutes
Special Considerations:
In situations where a customer is expressing a strong distrust for the
quality and reliability of the 300-1315-01 power supply then it may be
reasonable to replace the 300-1315-01 with the newer 300-1342-01 power
supply, but then only upon failure. Engineers should not take it upon
themselves to substitute part numbers as a general practice without
just cause.
Corrective Action:
Upon failure replace 300-1315-01 with 300-1315-01.
The 300-1342-01 may be used to replace the 300-1315-01 but only when
the 300-1315-01 is not available OR in situations as stated above under
the Special Considerations section.
Do not use a 300-1315-01 to replace a 300-1342-01.
Billing Type:
Warranty: Sun will provide parts at no charge under Warranty
Service. On-Site Labor Rates are based on how the
system was initially installed.
Contract: Sun will provide parts at no charge. On-Site Labor Rates
are based on the type of service contract.
Non Contract: Sun will provide parts at no charge. Installation by
Sun is available based on the On-Site Labor Rates
defined in the Price List.
--------------------------------------------------------------------------
Implementation Footnote:
________________________
i) In case of Mandatory FCOs, SunService will attempt to contact all known
customers to recommend the part upgrade.
ii) For controlled proactive swap FCOs, SunService mission critical support
teams will initiate proactive swap efforts for their respective accounts,
as required.
iii) For Replace upon Failure FCOs, SunService partners will implement the
necessary corrective actions as and when they are required.
SunWeb Access:
______________
All released FINs and FCOs can be accessed internally on the SunWeb using your
favorite network browser as follows:
* Access the top level URL of http://cte.corp/FIN_FCO/
* From there, select the appropriate link to query or browse the FIN and
FCO Homepage collections.
Supporting documents for FIN/FCOs can be found on Edist. Edist can be
accessed internally at the following URL: http://edist.corp/.
* From there, follow the hyperlink path of "SunService Documentation" and
click on "FIN & FCO attachments", then choose the appropriate folder, FIN or
FCO. This will display supporting directories/files for FINs or FCOs.
--------------------------------------------------------------------------
General:
________
Send questions or comments to finfco-manager@cte.Corp
---------------------------------------------------------------------------