Document Audience: | INTERNAL |
Document ID: | A0128-2 |
Title: | Ultra5 and Ultra10 systems may experience fuzzy video, slow booting and Serial port hang in SYNC mode (X.25). |
Copyright Notice: | Copyright © 2005 Sun Microsystems, Inc. All Rights Reserved |
Update Date: | Tue Jun 30 00:00:00 MDT 1998 |
---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------
FIELD CHANGE ORDER
(For Authorized Distribution by SunService)
FCO #: A0128-2
Status: inactive
Synopsis: Ultra5 and Ultra10 systems may experience fuzzy video, slow booting and Serial port hang in SYNC mode (X.25).Date: Jun/30/98
Keywords:
Ultra5 and Ultra10 systems may experience fuzzy video, slow booting and Serial port hang in SYNC mode (X.25)
Top FIN/FCO Report: Yes
Products Reference: Ultra5 / Ultra10 motherboard
Product Category: Desktop / System Board
Product Affected:
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
A21 A21 270 Ultra 5 270MHz Desktop < xW822ssssss *
A22 A22 300 Ultra 10 300MHz Desktop < xW822ssssss *
* Note: The affected system serial number for problems 1 and 2 is less
than xW817ssssss.
Parts Affected:
Part Number Description Model
----------- ----------- -------
375-0009-05 (or below) Motherboard, Ultra5/10 -
(SCSI Devices)
Type Vendor Model SerialNumber(Min) SerialNumber(Max) Firmware
---- ------ ------- ------------------ ------------------ --------
N/A
References:
ECO: WO_13038
ECO: WO_12616
ECO: WO_12861
LEAP: 884
BugId: 4120186, 4114784, 4114343
FIN: I0386-1, I0391-1
Esc: 513567
Issue Description:
This release of the FCO (FCO_A0128-2) adds a third problem and the associated
corrective action.
From FCO_A0128-1:
This FCO addresses two problems currently being experienced on this product;
1) System takes a long time to boot. System running Power On Self-Test even
though the diag-switch in the NVRAM was set to `false'. The boot counter
also was not incrementing as the number of power-cycles value could not be
updated for every new power cycle of the machine.
Root cause has been attributed to an unnecessary pull-up resistor (R310 a
location 0603) on the motherboard affecting the PWRGD2 signal from the power
supply. This could cause the system to reset too early and start to access
TOD before the TOD becomes enabled. This resistor was removed via ECO#
WO_12616 on motherboards 375-0009-05 available in manufacturing since
mid-February 1998.
2) Fuzzy video display on color monitors. The character edges are not sharp
and appear smeared to the right of the character. This gives dark text on
a white background a fuzzy or "dirty" appearance.
Root cause has been attributed to video circuitry on the motherboard. The
corrective action has been implemented via ECO# WO_12861 on motherboards
375-0009-07 available in manufacturing since mid-April 1998. Additionally,
any system with a serial number equal to or greater than xW817ssssss is
not affected as they will contain a -07 or later motherboard.
The system serial number can be interpreted as follows;
xW817ssssss
1st digit: Manufacturing site
2nd digit: W - Workstation
3rd digit: Calendar year
4th and 5th digit: Calendar week
last six digits: serial number
3) System may experience a serial port hang when using external clock source
as transfer clock in SYNC mode (X.25).
Due to the voltage drop across the 4.7K serial resistor, the output of the
clock driver (UC5180 at location U4) could not obtain a logic-low voltage
at the input of 74F04 (at location U43A) thus causing the serial port's
external clock input to fail.
Corrective action was to replace the 74F04 at location U43A with a 74ACT04
(p/n 100-2448-01) which rolls the Ultra 5/10 motherboard from 375-0009-07
to 375-0009-08. This corrective action was implemented via ECO# WO_13038
on motherboards 375-0009-08 available in manufacturing since May 15, 1998.
Any system with a serial number equal to or greater than xW822ssssss is
not affected as they will contain a -08 or later motherboard. Logistics
corrective action was implemented via LEAP_884 on May 15, 1998.
Implementation:
---
| | MANDATORY (Fully Pro-Active)
---
---
| | CONTROLLED PRO-ACTIVE (per Sun Geo Plan)
---
---
| x | UPON FAILURE or CUSTOMER REQUEST
---
Replacement Time Estimate:
30 minutes
Special Considerations:
Corrective Action:
For Problems 1 and 2 upon failure or at customer request replace;
375-0009-05 (or below) with 375-0009-07
For Problem 3 upon failure replace;
375-0009-07 (or below) with 375-0009-08
Comments:
Although ECO# WO_12546 released the 375-0009-06 this dash level was never used
in production.
Billing Type:
Warranty: Sun will provide parts at no charge under Warranty
Service. On-Site Labor Rates are based on how the
system was initially installed.
Contract: Sun will provide parts at no charge. On-Site Labor Rates
are based on the type of service contract.
Non Contract: Sun will provide parts at no charge. Installation by
Sun is available based on the On-Site Labor Rates
defined in the Price List.
--------------------------------------------------------------------------
Implementation Footnote:
________________________
i) In case of Mandatory FCOs, SunService will attempt to contact all known
customers to recommend the part upgrade.
ii) For controlled proactive swap FCOs, SunService mission critical support
teams will initiate proactive swap efforts for their respective accounts,
as required.
iii) For Replace upon Failure FCOs, SunService partners will implement the
necessary corrective actions as and when they are required.
--------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network
browser as follows:
SunWeb Access:
______________
* Access the top level URL of http://cte.corp/FIN_FCO/
* From there, select the appropriate link to query or browse the FIN and
FCO Homepage collections.
Supporting documents for FIN/FCOs can be found on Edist. Edist can be
accessed internally at the following URL: http://edist.corp/.
* From there, follow the hyperlink path of "SunService Documentation" and
click on "FIN & FCO attachments", then choose the appropriate folder, FIN or
FCO. This will display supporting directories/files for FINs or FCOs.
Internet Access:
_______________
* Access the top level URL of https://infoserver.Sun.COM
--------------------------------------------------------------------------
General:
________
Send questions or comments to finfco-manager@cte.Corp
---------------------------------------------------------------------------