Document Audience: | INTERNAL |
Document ID: | A0131-1 |
Title: | A5000 Network Arrays with only one Interface Board may encounter excessive "soft scsi resets" and "timeouts" when running disk firmware revision 117x. |
Copyright Notice: | Copyright © 2005 Sun Microsystems, Inc. All Rights Reserved |
Update Date: | Tue Jun 23 00:00:00 MDT 1998 |
---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------
FIELD CHANGE ORDER
(For Authorized Distribution by SunService)
FCO #: A0131-1
Status: inactive
Synopsis: A5000 Network Arrays with only one Interface Board may encounter excessive "soft scsi resets" and "timeouts" when running disk firmware revision 117x.Date: Jun/23/98
Keywords:
A5000 Network Arrays with only one Interface Board may encounter excessive "soft scsi resets" and "timeouts" when running disk firmware revision 117x
Top FIN/FCO Report: Yes
Products Reference: StorEdge A5000 Array
Product Category: Storage / A5000
Product Affected:
Systems Affected
------- ---------
Mktg ID Platform Model Description Serial Number
------- -------- ----- ----------- -------------
- A14 - Ultra Enterprise 2 -
- E450 - Ultra Enterprise 450 -
- E3000 - Ultra Enterprise 3000 -
- E3500 - Ultra Enterprise 3500 -
- E4000 - Ultra Enterprise 4000 -
- E4500 - Ultra Enterprise 4500 -
- E5000 - Ultra Enterprise 5000 -
- E5500 - Ultra Enterprise 5500 -
- E6000 - Ultra Enterprise 6000 -
- E6500 - Ultra Enterprise 6500 -
- E10000 - Ultra Enterprise 10000 -
X-options Affected
--------- --------
Mktg ID Platform Model Description Serial Number
-------- -------- ----- ----------- -------------
SG-XARY010A-45G A5000 - 45.5 GB Sun Enterprise Network Array -
SG-XARY010A-127G A5000 - 127.4 GB Sun Enterprise Network Array -
SG-XARY011A-127G A5000 - 127.4 GB Sun Enterprise Network Array -
SG-XARY012A-254G A5000 - 254.8 GB Sun Enterprise Network Array -
SG-XARY012A-509G A5000 - 509.6 GB Sun Enterprise Network Array -
Parts Affected:
Part Number Description Model
----------- ----------- -----
N/A
(SCSI Devices)
Type Vendor Model SerialNumber(Min) SerialNumber(Max) Firmware
---- ------ ------- ------------------ ------------------ --------
Disk Seagate ST19171FCSUN9.0G - - 117x
References:
FIN: I0389-1
Issue Description:
A5000 Network Arrays with only one (1) Interface Board (IB) and dash 04 disk
backplanes (501-4372-04) may encounter excessive "soft scsi resets" and
"timeouts" when running disk firmware revision 117x, even though diagnostics
such as lbf (loop back frame) may pass. A typical error message for this
failure would be as follows:
unix: sf0: Target 0x11 Reset successful
unix: WARNING: /sbus@a,0/SUNW,socal@2,0/sf@0,0/ssd@w22000020370ca5df,0 (ssd71):
unix: SCSI transport failed: reason 'timeout': retrying command
unix: WARNING: /sbus@a,0/SUNW,socal@2,0/sf@0,0/ssd@w22000020370ca5df,0 (ssd71):
unix: SCSI transport failed: reason 'reset': retrying command
unix: ssd71: Failed CDB:0x28 0x0 0x0 0x57 0x43 0x7d 0x0 0x0 0x28 0x0 0x0 0x0
unix: ssd71: Sense Data:0x70 0x0 0x6 0x0 0x0 0x0 0x0 0xa 0x0 0x0 0x0 0x0 0x29
0x0 0x2 0x0 0x0 0x0 0x7e 0x7e
unix: WARNING: /sbus@a,0/SUNW,socal@2,0/sf@0,0/ssd@w22000020370ca5df,0 (ssd71):
unix: Error for Command: read(10) Error Level: Informational
Requested Block: 5718909 Error Block: 5718909
unix: Vendor: SEAGATE Serial Number: 9801P60729
unix: Sense Key: Unit Attention
unix: ASC: 0x29 (power on, reset, or bus reset occurred), ASCQ: 0x0, FRU: 0x2
FC-AL disk drives with older chip sets are susceptible to noise coming off
the unused loop. This noise can cause the PLL to acquire false signal lock,
sending the drive in and out of sync, causing loop resets. This isssue is not
seen with the older chip set using the FCS FC-AL disk drive firmware (107x) or
when the newer chip revisions are used. These errors are rare and may never
be seen, even on affected arrays.
Installing a second Interface Board fixes this problem since it allows the disk
drive receivers on the unused loop to see valid FC idle ordered sets, get PLL
lock and word sync so that the FC-AL disk drive firmware can pay full attention
to the active loop. All StorEdge A5000 Arrays shipped beginning March 30, 1998
and after, will contain two (2) Interface Boards and will not see "soft scsi
resets" and "timeouts" on account of the above issue.
Implementation:
---
| | MANDATORY (Fully Pro-Active)
---
---
| | CONTROLLED PRO-ACTIVE (per Sun Geo Plan)
---
---
| X | UPON FAILURE
---
Replacement Time Estimate:
30 minutes
Special Considerations:
The IB Board can be hot swapped in without shutting down the array if the IB
Board is at firmware rev 1.03 or higher. The IB Board (501-2951-09) has
firmware rev 1.05.
Corrective Action:
Install a second IB Board (501-2951-09 or higher) into A5000 Network Arrays
experiencing this problem. Gigabit Interface Converters (GBIC) and host
connections are not required for this second Interface Board.
Comments:
New FC-AL disk drive firmware is under development to address this issue and
may be released at a later date as a final solution to this issue.
Billing Type:
Warranty: Sun will provide parts at no charge under Warranty
Service. On-Site Labor Rates are based on how the
system was initially installed.
Contract: Sun will provide parts at no charge. On-Site Labor Rates
are based on the type of service contract.
Non Contract: Sun will provide parts at no charge. Installation by
Sun is available based on the On-Site Labor Rates
defined in the Price List.
--------------------------------------------------------------------------
Implementation Footnote:
________________________
i) In case of Mandatory FCOs, SunService will attempt to contact all known
customers to recommend the part upgrade.
ii) For controlled proactive swap FCOs, SunService mission critical support
teams will initiate proactive swap efforts for their respective accounts,
as required.
iii) For Replace upon Failure FCOs, SunService partners will implement the
necessary corrective actions as and when they are required.
--------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network
browser as follows:
SunWeb Access:
______________
* Access the top level URL of http://cte.corp/FIN_FCO/
* From there, select the appropriate link to query or browse the FIN and
FCO Homepage collections.
Supporting documents for FIN/FCOs can be found on Edist. Edist can be
accessed internally at the following URL: http://edist.corp/.
* From there, follow the hyperlink path of "SunService Documentation" and
click on "FIN & FCO attachments", then choose the appropriate folder, FIN or
FCO. This will display supporting directories/files for FINs or FCOs.
Internet Access:
_______________
* Access the top level URL of https://infoserver.Sun.COM
--------------------------------------------------------------------------
General:
________
Send questions or comments to finfco-manager@cte.Corp
---------------------------------------------------------------------------