Document Audience: | INTERNAL |
Document ID: | A0132-1 |
Title: | When one or more PCI QFE cards are plugged into 33MHz slot(s) Ultra30 does not come out of reset when powered up. |
Copyright Notice: | Copyright © 2005 Sun Microsystems, Inc. All Rights Reserved |
Update Date: | Fri Jul 31 00:00:00 MDT 1998 |
---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------
FIELD CHANGE ORDER
(For Authorized Distribution by SunService)
FCO #: A0132-1
Status: inactive
Synopsis: When one or more PCI QFE cards are plugged into 33MHz slot(s) Ultra30 does not come out of reset when powered up.Date: Jul/31/98
Keywords:
When one or more PCI QFE cards are plugged into 33MHz slot(s) Ultra30 does not come out of reset when powered up
Top FIN/FCO Report: Yes
Products Reference: Ultra 30 / PCI QFE
Product Category: Desktop / Networking / Ethernet
Product Affected:
Systems Affected:
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
A16 A16 ALL Sun Ultra 30 Desktop Workstation -
X-options Affected:
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
X1034A - - Quad Fast Ethernet PCI Adapter -
Parts Affected:
Part Number Description Model
----------- ----------- -----
501-4366-04 Quad Fast Ethernet - PCI Adapter
(SCSI Devices)
Type Vendor Model SerialNumber(Min) SerialNumber(Max) Firmware
---- ------ ------- ------------------ ------------------ --------
N/A
References:
ECO: WO_12815
LEAP: 898
BugId: 4094903
Esc: 513032
Issue Description:
When one or more PCI QFE cards are plugged in 33MHz slot(s) Ultra30
does not come out of reset when powered up. This occurs intermittently
& the number of occurrences varies from power supply to power supply.
Symptoms include:
- System LED does not light up
- Power supply fan is running
- No display on the console or from the ttya port
Root cause has been attributed to a bridge component used in the delay
circuit of the PCI QFE board which caused improper resetting and a PCI
bus hang condition. A newer revision -AC of the bridge component
located at U0101 (DEC 21153) was incorporated to correct the problem.
The corrective action was implemented in Sun Manufacturing via ECO#
WO_12815 in April 1998.
Implementation:
---
| | MANDATORY (Fully Pro-Active)
---
---
| | CONTROLLED PRO-ACTIVE (per Sun Geo Plan)
---
---
| X | UPON FAILURE
---
Replacement Time Estimate:
30 minutes
Special Considerations:
Corrective Action:
Upon failure replace 501-4366-04 with 501-4366-05.
Billing Type:
Warranty: Sun will provide parts at no charge under Warranty
Service. On-Site Labor Rates are based on how the
system was initially installed.
Contract: Sun will provide parts at no charge. On-Site Labor Rates
are based on the type of service contract.
Non Contract: Sun will provide parts at no charge. Installation by
Sun is available based on the On-Site Labor Rates
defined in the Price List.
--------------------------------------------------------------------------
Implementation Footnote:
________________________
i) In case of Mandatory FCOs, SunService will attempt to contact all known
customers to recommend the part upgrade.
ii) For controlled proactive swap FCOs, SunService mission critical support
teams will initiate proactive swap efforts for their respective accounts,
as required.
iii) For Replace upon Failure FCOs, SunService partners will implement the
necessary corrective actions as and when they are required.
--------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network
browser as follows:
SunWeb Access:
______________
* Access the top level URL of http://cte.corp/FIN_FCO/
* From there, select the appropriate link to query or browse the FIN and
FCO Homepage collections.
Supporting documents for FIN/FCOs can be found on Edist. Edist can be
accessed internally at the following URL: http://edist.corp/.
* From there, follow the hyperlink path of "SunService Documentation" and
click on "FIN & FCO attachments", then choose the appropriate folder, FIN or
FCO. This will display supporting directories/files for FINs or FCOs.
Internet Access:
_______________
* Access the top level URL of https://infoserver.Sun.COM
--------------------------------------------------------------------------
General:
________
Send questions or comments to finfco-manager@cte.Corp
---------------------------------------------------------------------------