Document Audience: | INTERNAL |
Document ID: | A0138-1 |
Title: | SBus/FC SOC+ Host Adapters may experience recoverable data transfer read errors. |
Copyright Notice: | Copyright © 2005 Sun Microsystems, Inc. All Rights Reserved |
Update Date: | Fri May 14 00:00:00 MDT 1999 |
---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------
FIELD CHANGE ORDER
(For Authorized Distribution by SunService)
FCO #: A0138-1
Status: inactive
Synopsis: SBus/FC SOC+ Host Adapters may experience recoverable data transfer read errors.Date: May/14/99
Keywords:
SBus/FC SOC+ Host Adapters may
Top FIN/FCO Report: Yes
Products Reference: StorEdge A5000 Array
Product Category: Storage / A5000
Product Affected:
Systems Affected:
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
- A14 - Ultra Enterprise 2 -
- E450 - Ultra Enterprise 450 -
- E3000 - Ultra Enterprise 3000 -
- E3500 - Ultra Enterprise 3500 -
- E4000 - Ultra Enterprise 4000 -
- E4500 - Ultra Enterprise 4500 -
- E5000 - Ultra Enterprise 5000 -
- E5500 - Ultra Enterprise 5500 -
- E6000 - Ultra Enterprise 6000 -
- E6500 - Ultra Enterprise 6500 -
- E10000 - Ultra Enterprise 10000 -
X-options Affected:
--------- --------
- A5000 - Enterprise Network StorEdge A5000 -
- A5100 - Enterprise Network StorEdge A5100 -
- A5200 - Enterprise Network StorEdge A5200 -
X6730A - - SBus/FC HA w/GBIC Date Code 9833 and below
X2612 - - Sunfire I/O+ Date Code 9833 and below
X2622 - - Sunfire I/O+ Graphic Date Code 9833 and below
Parts Affected:
Part Number Description Model
----------- ----------- -------
501-3060-06 (or below) FC-AL SBus Card (FC100/S) -
501-5202-02 (or below) FC-AL SBus Card (FC100/S) -
501-5266-01 (or below) FC-AL SBus Card (FC100/S) -
501-4883-02 (or below) Sunfire I/O Board with SOC+ -
501-4884-02 (or below) Sunfire I/O Graphics Board with SOC+ -
501-4266-05 (or below) Sunfire I/O Board with SOC+ -
(SCSI Devices)
Type Vendor Model SerialNumber(Min) SerialNumber(Max) Firmware
---- ------ ------- ------------------ ------------------ --------
N/A
References:
FCO: A0144-2
DPCO: 134.A
WW StopShip: WW001#03533
BugId: 4110058
Issue Description:
SBus/FC SOC+ Host Adapters may experience recoverable data transfer read
errors. This can result in individual user applications, like Oracle, to
stop running.
Examples of errors are listed below.
a) SUNWvts /var/adm/messages file xfer errors with Release5 patches installed:
Jul 6 11:06:51 tester unix: WARNING: /sbus@2,0/SUNW,socal@d,10000/sf@1,0
(sf1):
Jul 6 11:06:51 tester unix: Transport error on target=0x4:
Fiber Channel: INCOMPLETE DMA XFER on sbus
The message "INCOMPLETE DMA XFER on sbus", indicates that the
transfer failed. This is a retryable error and the driver will
reissue the I/O.
b) SUNWvts log file xfer compare error with or without Release5 patches
installed:
Big compare failed on 'device', block 122491, offset 12876
The message indicates that the data transfer to memory does not
match that written to the disc.
c) ha.test error output with or without Release5 patches installed:
*** INTERNAL LOOPBACK: luxdiag int /devices/sbus@f,0/SUNW,socal@0,0:0 ***
*** TESTING PORT: lbf -t ffffffff -n 1000 -k 64 -c
/devices/sbus@f,0/SUNW,socal@0,0:0 ***
* pass 1 *
Ioctl returns: -1, errno = 5
Passes = 216.
Total elapsed time = 4 seconds.
Throughput = 3538944 bytes/sec.
* pass 2 *
Buffer mismatch at index 2039: expected ffffffff, actual 7fffffff.
Stopped at pass 122.
Passes = 122.
Total elapsed time = 2 seconds.
Throughput = 3997696 bytes/sec.
The "Buffer mismatch at index 2039: expected ffffffff, actual
7fffffff" potion of the messages indicates a bit failure on the
Host Adapter.
The root cause is related to bit corruption in the SBus interface internal to
the SOC+ chip (p/n 100-4262-02).
All SOC+ host adapters manufactured prior to the Date Code 9833, which
have not already been tested with random I/O, SUNWvts, or ha.test and
lbf62.scr are suspect.
Manufacturing implemented corrective action on August 6th, 1998 via
Worldwide Stopship/Purge WW001#03533. Enterprise Services implemented
corrective action by purging stock via DPCO# 134.A starting in late
January 1999.
Implementation:
---
| | MANDATORY (Fully Pro-Active)
---
---
| X | CONTROLLED PRO-ACTIVE (per Sun Geo Plan)
---
---
| | UPON FAILURE
---
Replacement Time Estimate:
30 minutes
Special Considerations:
Corrective Action:
1. Check patches and upgrade system to the latest Patches and Firmware
as required (see COMMENTS section below).
2. Check /var/adm/messages file for xfer errors.
3. Reseat all GBIC cards, optical cables and disk drives.
4. Run the Host adapter test and Loop Integrity test in the
STORtools diagnostic toolkit.
If no errors occur, or none are found in /var/adm/messages file
no further action is needed.
If any failures occur during testing, or are found in /var/adm/messages file,
replace those failing FRUs (if listed in PARTS AFFECTED section of this FCO)
with one having a date code later than 9833 or having a DPCO#134 label on the
assembly.
Comments:
As the above mentioned error messages could be caused by outdated software
or firmware please make sure that the latest patches and firmware revisions
are installed. Refer to the latest Patch and Firmware Matrix on;
http://storageweb.eng.sun.com/tm/photon/main/
Revision checking is also available with StorTools available for download from;
http://storageweb.eng/tm/STORtools/StorTools1.html
A single command verifies patch levels, array and drive firmware revisions,
and reports discrepancies.
Also reference FIN #: I0400-1:
StorEdge A5x00 disks drives should not be reconfigured such that there is
a backplane (front and rear) without any disk drives installed. This may
precipitate the generation of intermittent errors.
If the A5x00 must be configured with all disks on one backplane, the empty
backplane should be bypassed using the front panel module. Reference the
Enterprise Network Array Installation and Service Manual for detailed
instructions.
Billing Type:
Warranty: Sun will provide parts at no charge under Warranty
Service. On-Site Labor Rates are based on how the
system was initially installed.
Contract: Sun will provide parts at no charge. On-Site Labor Rates
are based on the type of service contract.
Non Contract: Sun will provide parts at no charge. Installation by
Sun is available based on the On-Site Labor Rates
defined in the Price List.
--------------------------------------------------------------------------
Implementation Footnote:
________________________
i) In case of Mandatory FCOs, Enterprise Services will attempt to contact
all known customers to recommend the part upgrade.
ii) For controlled proactive swap FCOs, Enterprise Services mission critical
support teams will initiate proactive swap efforts for their respective
accounts, as required.
iii) For Replace upon Failure FCOs, Enterprise Services partners will implement
the necessary corrective actions as and when they are required.
--------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network
browser as follows:
SunWeb Access:
______________
* Access the top level URL of http://sdpsweb.EBay/FIN_FCO/
* From there, select the appropriate link to query or browse the FIN and
FCO Homepage collections.
SunSolve Online Access:
_______________________
* Access the SunSolve Online URL at http://sunsolve.Central/
* From there, select the appropriate link to browse the FIN or FCO index.
Supporting Documents:
____________________
Supporting documents for FIN/FCOs can be found on Edist. Edist can be
accessed internally at the following URL: http://edist.Central/.
* From there, follow the hyperlink path of "SunService Documentation" and
click on "FIN & FCO attachments", then choose the appropriate folder,
FIN or FCO. This will display supporting directories/files for FINs or
FCOs.
Internet Access:
_______________
* Access the top level URL of https://infoserver.Sun.COM
--------------------------------------------------------------------------
General:
________
Send questions or comments to finfco-manager@sdpsweb.EBay