Document Audience: | INTERNAL |
Document ID: | A0184-1 |
Title: | SCI cards installed in E10000 systems may not initialize properly. |
Copyright Notice: | Copyright © 2005 Sun Microsystems, Inc. All Rights Reserved |
Update Date: | Mon Nov 26 00:00:00 MST 2001 |
---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------
FIELD CHANGE ORDER
(For Authorized Distribution by SunService)
FCO #: A0184-1
Status: active
Synopsis: SCI cards installed in E10000 systems may not initialize properly.Date: Nov/26/2001
Keywords:
SCI cards installed in E10000 systems may not initialize properlyinitialize properlyinitialize properly
SunAlert: N
Top FIN/FCO Report: No
Products Reference: SCI Card in E10000
Product Category: Server / System Board
Product Affected:
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
Systems Affected:
------- --------
- E10000 - Ultra Enterprise 10000 -
X-Options Affected
--------- -------
X1073A - - SCI SBus Board -
Parts Affected:
Part Number Description Model
----------- ----------- -----
370-2868-01 ASSY SCI Board -
(SCSI Devices)
Type Vendor Model SerialNumber(Min) SerialNumber(Max) Firmware
---- ------ ------- ------------------ ------------------ --------
N/A
References:
ECO: W0_21083
ESC: 528920
ESC: 529355
ESC: 529466
ESC: 529821
ESC: 530038
ESC: 530225
BugID: 4404667
LEAP: 1633
Manual: 805-2917-XX Sun Enterprise 10000 System Service Guide
Issue Description:
E10000 system board Scalable Coherent Interface (SCI) SBus cards have
the potential to be missed by hpost.
Upon initial power on of an E10000 system board, the SCI SBus card may fail
to initialize properly. When this happens, the card will not be configured
into the system by hpost and any devices connected via these cards will be
inaccessible. Any applications that are dependent on these cards and/or
their associated devices will become off-line.
Only E10000 systems with SCI Cards installed are affected.
The root cause determined that the vendor's SBus card does not
follow the SBus Card Specification. The fix is an update to the
Programmable Logic Device (PLD) on the SCI Card that continually
tries to initialize the vendor's card until successful.
Corrective action was put in place in Manufacturing by releasing part
number 370-2868-02 via ECO WO_21083 on July 10, 2001. Corrective action
was put in place in Enterprise Services via LEAP# 1633 on July 18, 2001.
Implementation:
---
| | MANDATORY (Fully Pro-Active)
---
---
| X | CONTROLLED PRO-ACTIVE (per Sun Geo Plan)
---
---
| | UPON FAILURE
---
Replacement Time Estimate:
1.5 hours
Special Considerations:
Only E10000 systems with SCI Cards (370-2868-01) are affected.
Corrective Action:
Upon Failure or upon customer need replace as follows;
replace 370-2868-01 with 370-2868-02
Identification of Suspect Part
------------------------------
1. Locate the Scalable Coherent Interface (SCI) SBus card part number.
If it is 370-2868-01 the E10000 system is affected and the board
should be replaced Proactively.
For detailed replacement procedures please refer to the Sun Enterprise 10000
System Service Guide (Sun p/n 805-2917-xx), or reference the following
postscript
document;
http://sdpsweb.Ebay/FIN_FCO/FCO/FCO_A0184-1_Dir/SBUS_Replacement.ps
Comments:
Billing Type:
Warranty: Sun will provide parts at no charge under Warranty
Service. On-Site Labor Rates are based on how the
system was initially installed.
Contract: Sun will provide parts at no charge. On-Site Labor Rates
are based on the type of service contract.
Non Contract: Sun will provide parts at no charge. Installation by
Sun is available based on the On-Site Labor Rates
defined in the Price List.
--------------------------------------------------------------------------
Implementation Footnote:
________________________
i) In case of Mandatory FCOs, Enterprise Services will attempt to contact
all known customers to recommend the part upgrade.
ii) For controlled proactive swap FCOs, Enterprise Services mission critical
support teams will initiate proactive swap efforts for their respective
accounts, as required.
iii) For Replace upon Failure FCOs, Enterprise Services partners will implement
the necessary corrective actions as and when they are required.
--------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network
browser as follows:
SunWeb Access:
______________
* Access the top level URL of http://sdpsweb.EBay/FIN_FCO/
* From there, select the appropriate link to query or browse the FIN and
FCO Homepage collections.
SunSolve Online Access:
_______________________
* Access the SunSolve Online URL at http://sunsolve.Central/
* From there, select the appropriate link to browse the FIN or FCO index.
Supporting Documents:
____________________
Supporting documents for FIN/FCOs can be found on Edist. Edist can be
accessed internally at the following URL: http://edist.Central/.
* From there, follow the hyperlink path of "SunService Documentation" and
click on "FIN & FCO attachments", then choose the appropriate folder,
FIN or FCO. This will display supporting directories/files for FINs or
FCOs.
Internet Access:
_______________
* Access the top level URL of https://infoserver.Sun.COM
--------------------------------------------------------------------------
General:
________
Send questions or comments to finfco-manager@sdpsweb.EBay
---------------------------------------------------------------------------