Document Audience:INTERNAL
Document ID:A0236-1
Title:Fan issues may occur on SunFire B1600 (B100s and B100x Server blades) where the fan speed falls below critical threshold values.
Copyright Notice:Copyright © 2007 Sun Microsystems, Inc. All Rights Reserved
Update Date:Fri Jul 16 00:00:00 MDT 2004

------------------------------------------------------------------------

- Sun Proprietary/Confidential: Internal Use Only -

------------------------------------------------------------------------

                            FIELD CHANGE ORDER
            (For Authorized Distribution by Enterprise Services)

FCO #: A0236-1
Status: inactive
Synopsis: Fan issues may occur on SunFire B1600 (B100s and B100x Server blades) where the fan speed falls below critical threshold values.
Date: July/16/2004
SunAlert: No
Top FIN/FCO Report: Yes
Products Reference: Sun Fire B1600
Product Category: Server / Component
Product Affected: 
Systems Affected:

Mkt_ID   Platform   Model   Description        
------   --------   -----   -----------        
-	 A44	    All	    Sun Fire B1600 Server	


X-Options Affected:

Mkt_ID      Platform             Description         
------      --------             -----------         

X7501A	    Sun Fire B1600	 Sun Blade B100s       
X7502A	    Sun Fire B1600	 Sun Blade B100s
X7503A	    Sun Fire B1600	 Sun Blade B100s       

X7512A	    Sun Fire B1600	 Sun Blade B100x		
X7513A      Sun Fire B1600	 Sun Blade B100x
Parts Affected: 
Part Number	           Description             	     
-----------	           -----------	

540-5079-06 (Or Less)	   Sun Blade B100s
540-5078-06 (Or Less)	   Sun Blade B100s
540-5454-06 (Or Less)	   Sun Blade B100s

540-5548-03 (Or Less)	   Sun Blade B100x
540-5549-03 (Or Less)	   Sun Blade B100x
540-5860-03 	           Sun Blade B100x


(SCSI Devices)
Type   Vendor    Model     SerialNumber(Min)   SerialNumber(Max)   Firmware
----   ------    -------   -----------------   -----------------   --------
N/A
References: 
ESC:	549061, 549378, 547981
   FIN:	I1079-1	
   ECO:	WO_28422, WO_28723	
   LEAP: 2585, 2598, 2598
   WWStopShip:	P200-20205.A1	
   Manual: 817-3432-12	Blade System Chassis Administration Guide
Issue Description: 
Fan issues may occur on SunFire B1600 (B100s and B100x Server blades) where the fan
speed falls below critical threshold values.  

All three of the Sun Blade B100s blades and the two Sun Blade B100x blades are
susceptible to this failure mode as the CPU cooling fan is a common part. The system
detects the fan speed falling below the critical threshold (70% of maximum)
resulting in a warning message being displayed.  There are no specific
user/environmental conditions which contribute to this issue.

The following error message will be displayed on the Sun Fire B1600 shelf System
Controller console and in the Console Log when a fan has this issue:

   Nov 19 08:34:28: CRITICAL: S12: CPU Fan speed below critical threshold.

Use the "show environment -v" command at the Sun Fire B1600 Shelf System 
Controller Prompt to identify affected components.

The following is an example that shows affected blades:

   System Fans (RPM)               Current   Status    Warning   
   ---------------------------------------------------------------------
   S0         /fan/cpu_fan         100%      OK        66%
   S1         /fan/cpu_fan         100%      OK        66%
   S2         /fan/cpu_fan         100%      OK        66%
   S3         /fan/cpu_fan           0%   Fault        66%
   S4         /fan/cpu_fan         100%      OK        66%
   S5         /fan/cpu_fan         100%      OK        66%
   S6         /fan/cpu_fan         100%      OK        66%
   S7         /fan/cpu_fan         100%      OK        66%
   S8         /fan/cpu_fan           0%   Fault        66%
   S9         /fan/cpu_fan         100%      OK        66%
   S10        /fan/cpu_fan         100%      OK        66%
   S11        /fan/cpu_fan         100%      OK        66%
   S12        /fan/cpu_fan         100%      OK        66%
   S13        /fan/cpu_fan           0%   Fault        66%
   S14        /fan/cpu_fan         100%      OK        66%
   S15        /fan/cpu_fan           0%   Fault        66%

NOTE: The fans on blades S3, S8, S13 and S15 are shown above as faulty.


This issue was root caused as a result of damage within the bearing mechanism.
However, the fan vendor has not identified what causes the accelerated wearout and
the actual cause remains unidentified.

It has been decided to qualify a fan from another supplier. 

The CPU fans in the Sun Blade B100s and B100x have been replaced with a fan 
from the new supplier. 

The corrective action was made available by Sun manufacturing
via ECOs: WO_28422 and WO_28723.

The corrective action was made available by Sun Services 
via LEAPs: 2585, 2598, 2598.
Implementation: 
---
|   |   MANDATORY (Fully Pro-Active)
 ---


 ---
|   |   CONTROLLED PRO-ACTIVE (per Sun Geo Plan)
 ---


 ---
| X |   UPON FAILURE
 ---
Replacement Time Estimate: 
0.5 hours
Special Considerations: 
*******************************
              *** Phased Release Schedule ***
              *******************************
              
This FCO will have a timezone phased release based on material
readiness as follows:

   EMEA                     July 16, 2004
   US/Canada/Ltn Amer       July 30, 2004
   APAC/Japan               August 20, 2004

The above dates represent when each timezone has determined
they will be materially ready to support this FCO.

NOTE: This FCO does not authorize the proactive replacement of hardware.
For customers who request proactive relacement, please address this 
through the account teams and the CIC program.  Reference the following 
URL for more information on the CIC program:

   http://uscq.ebay/Process/cic.html
Corrective Action: 
Remove the affected Blade and replace with a new part as listed below:

for Sun Blade B100s:

   - replace 540-5078-06 (or less) with 540-5078-07 (or above)
   - replace 540-5079-06 (or less) with 540-5079-07 (or above)
   - replace 540-5454-06 (or less) with 540-5454-07 (or above)

for Sun Blade B100x:
	
   - replace 540-5548-03 (or less) with 540-5860-04 (or above)
   - replace 540-5549-03 (or less) with 540-5860-04 (or above)
   - replace 540-5860-03 (or less) with 540-5860-04 (or above)
	
For B100x, parts 540-5548 and 540-5549 (Scimitar 1P) blades, memory DIMMs need to be
removed from the affected blade and inserted into the replacement FRU 540-5860.
These blades have customer replaceable memory and the FRU is the blade without
memory.

In the case of the B100s (Stiletto) blade, the FRU includes the memory as this is
not customer replaceble.

The procedure for removing a blade from the chassis (B100s and B100x) is documented
in the Blade System Chassis Administration Guide.  The latest version is
817-3432-12. 

The procedure for removing the memory on the B100x can be found in the 1P DIMM
Replacement Guide (817-2577-10).  These manuals can be found at the following URL:

  http://www.sun.com/products-n-solutions/hardware/docs/Servers/Workgroup_Servers/Sun_Fire_Blade_Platform/Sun_Fire_b100x/index.html
Comments: 
When returning the Sun Blade B100x, it should be returned as F540-5860.  This
is the normal practice for the Sun Blade B100x.

When shipped as a new "system", the B100x barcode labels include:

 Blade serial number		BLADE SN: 002412
 barcode			||||||||||||||||

 Manufacturing serial number	MFG SN:HS34132650
 barcode			||||||||||||||||
 abbreviated description        MB R2B/1.53GHZ/30GB S01/2x1GB S03

 Assembly part number           P/N: 540-5549-02
 barcode			||||||||||||||||
 FRU P/N F540-5860              FRU P/N F540-5860
Billing Type: 
Warranty: Sun will provide parts at no charge under Warranty 
           Service. On-Site Labor Rates are based on how the
           system was initially installed.

 Contract: Sun will provide parts at no charge. On-Site Labor Rates
           are based on the type of service contract.

 Non Contract: Sun will provide parts at no charge. Installation by
               Sun is available based on the On-Site Labor Rates 
               defined in the Price List.

--------------------------------------------------------------------------
Implementation Footnote: 
________________________

i)   In case of Mandatory FCOs, Sun Services will attempt to contact
      all known customers to recommend the part upgrade.

ii)  For controlled proactive swap FCOs, Sun Services mission critical
     support teams will initiate proactive swap efforts for their respective 
     accounts, as required.

iii) For Replace upon Failure FCOs, Sun Services partners will implement
     the necessary corrective actions as and when they are required.

--------------------------------------------------------------------------
 
All released FINs and FCOs can be accessed using your favorite network 
browser as follows:
 
SunSolve Internal Access:
_______________________
 
* Access the SunSolve Online URL at http://sunsolve.Central/

* From there, select the appropriate link to browse the FIN or FCO index.

Internet Access:
_______________
 
* Access the top level URL of  https://spe.sun.com


FIN/FCO Homepage Access: 
_________________________
 
* Access the top level URL of http://sdpsweb.Central/FIN_FCO/index.html

* From there, select the appropriate link to query or browse the FIN and
  FCO Homepage collections.

To submit either a FIN or FCO refer to the following URLs for templates
and instructions;

*  For FCO: http://pronto.central/fco.html
*  For FIN: http://pronto.central/fin.html
 
--------------------------------------------------------------------------
General:
________

Send questions or comments to finfco-manager@Sun.COM

---------------------------------------------------------------------------
Statusinactive