Document Audience:INTERNAL
Document ID:A0239-1
Title:Seagate Cheetah 7 FC-AL disk drives may experience higher than expected failure rate.
Copyright Notice:Copyright © 2007 Sun Microsystems, Inc. All Rights Reserved
Update Date:Fri Dec 03 00:00:00 MST 2004

__________________________________________________________________

***  Sun Confidential:  Internal Use and Authorized VARs Only  ***
__________________________________________________________________

This message including any attachments is confidential information
of Sun Microsystems, Inc.  Disclosure, copying or distribution is
prohibited without permission of Sun.  If you are not the intended
recipient, please reply to the sender and then delete this message.
__________________________________________________________________


                        FIELD CHANGE ORDER
            (For Authorized Distribution by Sun Services)
            
FCO #: A0239-1
Status: inactive
Synopsis: Seagate Cheetah 7 FC-AL disk drives may experience higher than expected failure rate.
Date: Dec/3/2004
SunAlert: No
Top FIN/FCO Report: Yes
Products Reference: Seagate Cheetah 7 FC-AL disks
Product Category: Storage / Disk
Product Affected: 
Systems Affected:

Mkt_ID   Platform   Model   Description                   Serial Number
------   --------   -----   -----------                   -------------
  -	 Anysys      -      System Platform Independent       	-
 
      
X-Options Affected:

Mkt_ID      Platform    Model    Description              Serial Number      
------      --------    -----    -----------              -------------
  -	    A5200	All	Sun StorEdge A5200 Array	-	
  -	    D1000	All	Sun StorEdge D1000 Array	-	
  -	    st D130     All     Netra st D130			-		
  -	    3310        All	Sun StorEdge 3310 Array		-	
  -	    3510	All	Sun StorEdge 3510 Array		-	
  -	    5210        All	Sun StorEdge 5210 Array		-
  -	    6020/6120	All	Sun StorEdge 6020/6120 Array	-	
  -	    6900        All	Sun StorEdge 6900 Array		-	
  -	    6920	All	Sun StorEdge 6920 Array		-	
  -	    D2	        All	Sun StorEdge D2 Array		-	
  -	    D240	All	Sun StorEdge D240 Media Tray	-	
  -	    A1000	All	Sun StorEdge A1000 Array	-	
  -	    MultiPack	All	Sun StorEdge MultiPack		-	
  -	    S1	        All	Sun StorEdge S1 Array		-	
  -	    T3	        All	Sun StorEdge T3 Array		-
  -         T3+         All     StorEdge T3+                    -	
  -	    3910/3960	All	Sun StorEdge 3900 Series	-	
  -	    A3500	All	Sun StorEdge A3500 Array	-	
  -	    A5000	All	Sun StorEdge A5000 Array	-	
  -	    A5100	All	Sun StorEdge A5100 Array	-
Parts Affected: 
Part Number	Description  	Model              	     
---------       -----------	-----
540-5522-01 	36GB SCSI  	ST336607LC 	
540-5629-01 	73GB FCAL  	ST373307LC 	
540-4520-01 	36GB SCSI  	ST336607LC 	
540-4525-01 	36GB FCAL  	ST336607FC 	
540-5455-01 	73GB SCSI  	ST373307LC 	
540-4521-01 	36GB SCSI  	ST336607LC 	
540-5456-01 	73GB SCSI  	ST373307LC 	
540-5693-01 	36GB SCSI  	ST336607LC 	
540-5459-01 	146GB FCAL 	ST3146807FC 	
540-5563-01 	73GB SCSI  	ST373307LC 	
540-5330-01 	73GB FCAL  	ST373307FC 	
540-5771-01 	73GB SCSI  	ST373307LC 	
540-4689-01 	36GB SCSI  	ST336607LC 	
540-4519-01 	73GB FCAL  	ST373307FC 	
540-5937-02 	73GB SCSI  	ST373307LC 	
540-5471-01 	146GB FCAL 	ST3146807FC 	
540-4904-01 	36GB SCSI  	ST336607LC 	
390-0106-01 	73GB SCSI  	ST373307LC 	
540-5408-01 	73GB FCAL  	ST373307FC 	
540-4905-01 	73GB FCAL  	ST373307FC 	
540-5735-01 	146GB SCSI 	ST3146807LC 	
540-5626-01 	146GB FCAL 	ST3146807FC 	
540-4367-01 	36GB FCAL  	ST336607FC 	
540-4919-01 	36GB SCSI  	ST336607LC 	
540-5451-01 	36GB SCSI  	ST336607LC 	
540-5462-01 	36GB SCSI  	ST336607LC 	
540-5694-01 	73GB FCAL  	ST373307FC 	
540-5936-02 	36GB SCSI  	ST336607LC 	
540-5698-01 	36GB FCAL  	ST336607FC 	
390-0109-01 	36GB SCSI  	ST336607LC
References: 
DPCO: 434 
ESC:  550349
ECO:  WO_27575
FIN:  I1136-1
Issue Description: 
-----------------------------------------------------------------
| Change History:						  |
|								  |
| Nov/3/2004							  |  
| Added Note regarding lack of FW support for SE3310/3510 in      | 
| FIN I1136-1.                                                    |
|                                                                 |
| Dec/3/2004                                                      |
| Updated Special Consideration section.                          |
 -----------------------------------------------------------------
 
Seagate Cheetah 7 FC-AL disk drive models ST336607FC, ST373307FC,
ST3146807FC, and SCSI disk drive models ST336607LC, ST373307LC,
ST3146807LC with serial numbers below 60000 (Sun mfg date codes less
than 0340) are experiencing a higher than expected failure rate due
to a spindle motor issue.

Engineering failure analysis of returned and failed disk drives has
revealed a higher than normal incidence of a particular failure
mode.  While the overall global install base of Seagate Cheetah 10k.6
family of disk drives is meeting or close to meeting overall quality
goals, Sun has been advised of certain instances of Cheetah 10k.6 disk
drives impacting our customers. 


Serial Number Exposure
----------------------

Type  Vendor    GB/TYPE    Model        Seagate Serial#
----  ------    --------   -----------  --------------
DISK  SEAGATE   146 FCAL   ST3146807FC  3HY5xxxx... (or below)
DISK  SEAGATE   146 SCSI   ST3146807LC  3HY5xxxx... (or below)
DISK  SEAGATE    73 FCAL   ST373307FC   3HZ5xxxx... (or below)
DISK  SEAGATE    73 SCSI   ST373307LC   3HZ5xxxx... (or below)
DISK  SEAGATE    36 FCAL   ST336607FC   3JA5xxxx... (or below)
DISK  SEAGATE    36 SCSI   ST336607LC   3JA5xxxx... (or below)


Visual Inspection of Drives
---------------------------

There are two different serial number schemes on these drives.  Either
the Seagate serial number or the Sun serial number can be used to determine
if a drive is affected as described below.

1. Example Seagate Serial Number: 3HZ0YKVP00007336

The first 3 characters, "3HZ" in this case, is the vendor code identifying
the drive capacity and generation.

The Seagate serial number scheme is based on a base-34 number (0-9 numeric,
A-Z minus I and O alpha). The most significant bit is in the first position
after the "3HZ" descriptor.  In other words, the fourth character, "0" in
this case, is the first digit of the serial number.  Any above listed drives
with a 5 or below for this character should be considered affected. 


2. Example Sun Serial Number on drive: 0020772-0340A12345
   
Model indentifier(s) in serial number:

Seagate 10K6   36Gb ="A" both SCSI & FCAL
               73GB ="B" both SCSI & FCAL
              146GB ="C" both SCSI & FCAL
  
Seagate Vendor code: 0020772
Manufacture week code: -0340          (This means year 2003, week 40)
Identifier:  A                        (36GB SCSI & FCAL)
Last five digits alpha/numeric: 12345 (risk group = numbers below 60000)


Symptoms
--------

The specific failure mode is spindle motor failure. Unfortunately this
failure mode results in a DNR or Drive Offline condition with no
leading indicators or previous error messages.

The most frequent failures seen are, "Drive not ready" or the drive
may produce excessive read, write or media errors.

 Sample error messages:

 Mar 03 15:52:03 array02 ISR1[1]: N: u1d07 SCSI Disk Error Occurred (path = 0x0)
 Mar 03 15:52:03 array02 ISR1[1]: N: Sense Key = 0x1, Asc = 0x3, Ascq = 0x0

 Mar 03 15:52:08 array02 ISR1[1]: W: u1d07 SCSI Disk Error Occurred (path = 0x0)
 Mar 03 15:52:08 array02 ISR1[1]: W: Sense Key = 0x3, Asc = 0x3, Ascq = 0x0 
 Mar 03 15:52:08 array02 ISR1[1]: W: Sense Data Description = Peripheral Device Write Fault

 Mar 05 17:48:34 array02 ISR1[1]: W: u1d07 SCSI Disk Error Occurred (path = 0x0)
 Mar 05 17:48:34 array02 ISR1[1]: W: Sense Key = 0x3, Asc = 0x31, Ascq = 0x0

 Mar 05 17:48:34 array02 ISR1[1]: W: u1d07 SCSI Disk Error Occurred (path = 0x0)
 Mar 05 17:48:34 array02 ISR1[1]: W: Sense Key = 0x4, Asc = 0x19, Ascq = 0x0 
 

Identification of Affected Parts
-------------------------------- 

For all systems, to determine if a system has one of the Seagate Cheetah 7
drives, do one of the following:

If the system is down, run the "probe-scsi" command from the "ok" prompt.

If the system is up, run the "format" command.

If Explorer has run, check the file /opt/SUNWexplorer/bin/diskinfo.

  For A1000/A3x00 Arrays attached to a host, an alternative would be to
  run one of the two following commands:

  A. run #/usr/lib/osa/bin/drivutil -i /sccli/

  for example:

  ./se3kxtr.8302ae82.cheyenne-2004.01.09.20.17/sccli/SN#002AEE


When this issue occurs, the following error codes may indicate that a drive
has failed due a failed spindle motor:  

  "Sense Code 02x04"

Sample error messages:

  /sbus@7,0/QLGC,isp@0,10000/sd@1,0 (sd46):
  Error for Command: writeError Level: Fatal
  Sense Key: Hardware Error
  ASC: 0x2 (no seek complete), ASCQ: 0x0, FRU: 0x0

  10098107  c1t8d0

  /sbus@7,0/QLGC,isp@0,10000/sd@1,0 (sd46):
  Error for Command: readError Level: Fatal
  Sense Key: Vendor Unique
  ASC: 0x80 (), ASCQ: 0x0, FRU: 0xa

  10102117  c2t10d0

  /sbus@7,0/QLGC,isp@0,10000/sd@a,0 (sd54):
  Error for Command: readError Level: Fatal
  Sense Key: Media Error
  ASC: 0x11 (unrecovered read error), ASCQ: 0x0, FRU: 0x0

  10102117  c1t5d0
 
  /sbus@3,0/QLGC,isp@0,10000/sd@0,0 (sd15):
  Error for Command: writeError Level: Fatal
  Sense Key: Media Error
  ASC: 0x3 (peripheral device write fault), ASCQ: 0x0, FRU: 0x0

  10088635  c2t13d0
  
  /sbus@6,0/QLGC,isp@1,10000/sd@d,0 (sd42):
  Error for Command: load/start/stopError Level: Retryable
  Sense Key: Not Ready
  ASC: 0x4 (LUN not ready), ASCQ: 0x0, FRU: 0x0

  10096449  c2t9d0   5


Root cause has determined that spindles at the ends of the tolerance
distribution, may result in less oil, which may lead to inadequate
lubrication and thus cause the drive to fail.

Seagate has implemented a new spindle motor design as well as an enhanced
test in their manufacturing process.  This fix was implemented at Sun
via ECO# WO_27575.

All parts with affected date codes began being purged from all Services
Regional Stocking Locations via DPCO 434 as of March 15, 2004.

See FINI1136-1 for recommended disk firmware which can help to prevent 
unexpected disk outages due to this issue.  Note: This FIN does not support 
the Minnow SE3310/SE3510 at this time.  It will be supported in the 4.1.1 
firmware release and this FCO and the FIN will be updated at time of release.
Implementation: 
---
|   |   MANDATORY (Fully Pro-Active)
 ---

 ---
|   |   CONTROLLED PRO-ACTIVE (per Sun Geo Plan)
 ---

 ---
| X |   UPON FAILURE
 ---
Replacement Time Estimate: 
0.5 hours
Special Considerations: 
No proactive drive replacements are authorized by this FCO.

If any customer is experiencing a failure rate on these drives that is
higher than expected, please provide full and complete answers to the
following five questions and send them to the disk drive team at:

   Seagate_10K.6_disk_drive_team@sun.com
   
   
1. Have you advised the customer of the Seagate 10K.6 disk drive FW fix
   for this issue?
 
   Reference FIN ID I1136-1**
   Synopsis:   Improved firmware for Seagate 10K.6 disk drives will
   reduce the incidence of unexpected outages due to a spindle motor
   issue.
 
2. Customer: Identify the customer, and briefly outline the customer's
   compute and business environment.   Include platform mix, and
   disk drive type and distribution.

3. Describe why you think there is an issue and why this relates to
   FCO A0239-1.  Provide number of failures (if you can by month),
   error messages, requested eCPAS, and eCPAS results.
 
4. What action are you proposing for this customer?
  
5. Additional information which will help in understanding this 
   customer's situation.
  
**NOTE: Does not apply to 3310/3510 at this time.  Seagate 10K.6 disk
drive FW fix will be rolled out with next Minnow controller firmware
revision level 4.11 (expected release date is: Feb 2005)
Corrective Action: 
Upon Failure Only, replace like for like part numbers using normal
service procedures.

Good Seagate drives will have a DPCO 434 label or be outside of the
affected serial number range.
Comments: 
Implementation of firmware upgrades as recommended in FIN I1136-1 can
reduce the likelihood that this spindle motor issue will lead to
unexpected disk outages.

________________________________________________________________________

NOTE: FCO Tracking Instructions for Radiance/SPWeb:
--------------------------------------------------

If a Radiance case involves the application of an FCO to solve a customer
issue, please complete the following steps in Radiance/SPWeb prior to
closing the case:
 
    o Select "Field Change Order" in the REFERENCE TYPE field.

    o Enter FCO ID number in the REFERENCE ID field.
      For example; A0222-1.

If possible, include additional details in the REFERENCE SUMMARY field
(ie. Upgrade complete, customer declined, etc.)
________________________________________________________________________

Implementation Notes
--------------------

In case of "Mandatory" FCOs, Sun Services will attempt to contact
all known customers to recommend proactive implementation.

For "Controlled Proactive" FCOs, Sun Services mission critical
support teams will initiate proactive implementation efforts for
their respective accounts, as required.

For "Upon Failure" FCOs, Sun Services and partners will implement
the necessary corrective actions as the need arises.

The CIC process must be used for proactive hardware replacement
requests when an FCO is classified as "Upon Failure".


Billing Information
-------------------

Warranty: Sun will provide parts at no charge under Warranty
          Service.  On-Site Labor Rates are based on specified
          Warranty deliverables for the affected product.

Contract: Sun will provide parts at no charge.  On-Site Labor Rates
          are based on the type of service contract.

Non Contract: Sun will provide parts at no charge.  Installation by
              Sun is available based on the On-Site Labor Rates
              defined in the Price List.

________________________________________________________________________

All FCO documents are accessible via Internal SunSolve.  Type "sunsolve"
in a browser and follow the prompts to Search Collections.

For questions on this document, please email:

        finfco-manager@Sun.com

The FIN and FCO homepage is available at:

        http://sdpsweb.central/FIN_FCO/index.html

For more information on how to submit a FCO, go to:

        http://pronto.central/fco.html

To access the Service Partner Exchange, use:

        https://spe.sun.com

________________________________________________________________________
Statusinactive