Document Audience: | INTERNAL |
Document ID: | A0257-1 |
Title: | If the SE5210 LSI MegaRaid board battery is fully discharged, in the event of a power outage any data in the cache will be lost. |
Copyright Notice: | Copyright © 2007 Sun Microsystems, Inc. All Rights Reserved |
Update Date: | Fri Oct 20 00:00:00 MDT 2006 |
_____________________________________________________________
*** Sun Confidential: Internal Use and Authorized VARs Only ***
__________________________________________________________________
This message including any attachments is confidential information
of Sun Microsystems, Inc. Disclosure, copying or distribution is
prohibited without permission of Sun. If you are not the intended
recipient, please reply to the sender and then delete this message
__________________________________________________________________
FIELD CHANGE ORDER
(For Authorized Distribution by Sun Services)
FCO #: A0257-1
Status: active
Synopsis: If the SE5210 LSI MegaRaid board battery is fully discharged, in the event of a power outage any data in the cache will be lost.Date: Oct/20/2006
SunAlert: 101878
Top FIN/FCO Report: No
Products Reference: Sun StorEdge 5210 NAS
Product Category: Storage
Product Affected:
Systems Affected:
Mkt_ID Description
------ -----------
XTA5210R11A1NU876 Sun StorEdge 5210 NAS (includes the RAID and Ethernet cards)
XTA5210R11A1GU876 Sun StorEdge 5210 NAS (includes the RAID card)
XTA5210R11A1MU876 Sun StorEdge 5210 NAS 1 RAID, DP Optical NIC
XTA5210R11A2GU876 Sun StorEdge 5210 NAS 2 RAID
XTA5210R11A2MU876 Sun StorEdge 5210 NAS 2 RAID, DP optical NIC
X-Options Affected:
Mkt_ID Platform Model Description
------ -------- ----- -----------
N/A
Parts Affected:
Part Number Description
----------- -----------
540-6250-03 (or lower) MegaRAID 320 - 2X Dual Ultra-320 SCSI
References:
GSAP: 3100, 3664.A
ECO: ECO WO_31006, WO_31159, WO_34138
URL: http://sunsolve.central.sun.com/handbook_internal/Systems/5210NAS/components.html#WholeSystemFRU
Issue Description:
The battery on the SE5210 LSI MegaRAID board is not charged or maintained after
initial startup but the write cache is always set to write back. When the battery
is fully discharged, if there is a power outage any data in the cache will be lost.
This can cause data corruption or data loss.
Affected StorEdge 5210 systems in the field will have a 540-6250-03 (upper level
part number) or lower. The MegaRAID card (less the TTBU memory DIMM) will have
a part number of 375-3208-02 or lower.
While waiting to schedule the replacement, a PCI reset or power cycle will
recharge the battery and lower data loss/corruption probability.
A customer list identifying affected systems can be viewed via the
below "Internal Only" URL:
http://sunwebcollab.central.sun.com/gm/document-1.9.1232010
To assist the field in a communication of this issue to customers, a
Customer Letter is provided via the URL:
http://sdpsweb.central/FIN_FCO/FCO/A0257-1/SPE/FCO257Legal_custlett-1_v4.sxw
Root cause is provided below:
1. Battery not detected by charging circuit by the MegaRAID daughter board
2. Erroneous cache management policy by the MegaRAID firmware
3. Inaccurate communication of states to the 5210 Host
Corrective action was made available by Sun manufacturing via ECO# WO_31006
released May 6, 2005.
Corrective action was made available by Sun Services via GSAP# 3100.
Parts Affected:
Mar/31/2007
Implementation:
---
| X | MANDATORY (Fully Pro-Active)
---
---
| | CONTROLLED PRO-ACTIVE (per Sun Geo Plan)
---
---
| | UPON FAILURE
---
Replacement Time Estimate:
2 hours per system
Special Considerations:
This FCO will have a time zone phased release based on material readiness
for new part number 540-7078-01 as follows:
Readiness Date
--------------
US/Canada READY
Ltn America Dec/04/2006
EMEA Nov/27/2006
APAC Dec/11/2006
ANZO Dec/11/2006
Japan Dec/04/2006
The above dates represent when each time zone has determined that it will be
materially ready to support this FCO. All dates are estimates. Please check
with your Logistics Representative for more information with regard to material
availability. These dates only represent material readiness for the new part
number listed above. All other part numbers listed in the Corrective Action
section below have been available for some time.
Corrective Action:
External customers should be remediated first. Please use the Supply Date
for the external customers to assist with prioritization.
Proactively perform the following:
Replace 540-6250-03 (or lower) with both of the following 2 parts:
1. 540-6250-04 (or above) or 540-7078-01 (or above) or 540-7140-01 (or above)
- MegaRAID 320 2X Dual Ultra-320 SCSI
2. 556-4438-01 (or above) - 5210-FCO 257 DOC/OS
Notes:
- Ignore the printed documentation coming with part 556-4438 as it
is outdated. Instead refer to PDF version linked below instead!
http://sdpsweb.central/FIN_FCO/FCO/A0257-1/SPE/819-2297-11.revB_10-20-06.pdf
- The above 2 parts must be ordered as separate FRUs/CRUs.
- The following two 5210 system models, contain 2 RAID cards each:
Mktg P/N XTA5210R11A2GU876
SE5210 6x146GB HDD; 2 RAID cont Sun StorEdge 5210
NAS Rack Ready Appliance
Mktg P/N XTA5210R11A2MU876
SE5210 2port MMF NIC; 2RAID cnt Sun StorEdge 5210
NAS Rack Ready Appliance
Therefore, order a quantity of 2 of the MegaRAID cards for
each affected system.
- Affected systems in the field will have a 540-6250-03 or less
(upper level part number including both the RAID card and
the TTBU Memory DIMM); on this board will be a 375-3208-02
RAID CARD.
- New part revision 540-6250-04 was cut-in on May 6, 2005 and
is contained in shipping Sun StorEdge 5210 NAS as well as
the above kit.
- 556-4438 FCO kit includes the parts listed below:
Part Description Part Number
----------------- ----------
Field Change Order document 819-2997-10
NAS Software CD containing the OS 4.05 Build 14 725-1387-01
Included in the above kit are special instructions for installing
the kit. For your convenience, these instructions are also available
at the following URL as Sun document 819-2997-11:
http://sdpsweb.central/FIN_FCO/FCO/A0257-1/SPE/819-2297-11.revB_10-20-06.pdf
FCO Instructions for Sun StorEdge 5210 NAS
RAID Card / Battery Replacement Procedure
Comments:
Parts return process
--------------------
Please remember to put "FCO A0257-1" on the Defective Material Tag (DMT)
for all defective returns.
Affected systems in the field will be 540-6250-03 or less.
This upper level part number assembly includes both the
RAID card (p/n 375-3208-02) and the TTBU Memory DIMM.
IMPORTANT: Be careful not to damage or remove the DIMM from
the assembly.
The 540-6250-03 or less MUST be returned as a complete assembly
to get credit and to have the FRUs reworked and returned to stock.
CHANGE HISTORY:
Sep/30/05 - Initial release of FCO.
May/10/06 - Added important return instructions in COMMENTS section.
May/30/06 - Changed Target Completion date from Sep/30/06 to Mar/31/07.
Aug/23/06 - Due to not all defective parts being returned, changed the FRU
replacement p/ns from 3 parts to only two parts by combining
375-3208 and 370-7059 into the 540-6250 as well as adding a
sub-part number for the 540-6250 of 540-7078.
Oct/20/06 - Modified rework instructions in CORRECTIVE ACTION section.
Updated Replacement Procedures doc from -10 to -11 and to
make this doc and the customer list visible to our partners
via SPE.
Nov/20/06 - Updated Readiness Dates for new part number in the Special
Considerations section.
________________________________________________________________________
All FCO documents are accessible via Internal SunSolve. Type "sunsolve"
in a browser and follow the prompts to Browse or Search Collections.
For questions on this document, please email:
finfco-manager@Sun.com
The FCO home page is available at:
http://tns.central/fco
For more information on how to submit a FCO, go to:
http://pronto.central/fco.html
To access the Service Partner Exchange, use:
https://spe.sun.com
NOTE: FCO Tracking Instructions for Radiance/SPWeb:
--------------------------------------------------
If a Radiance case involves the application of an FCO to solve a customer
issue, please complete the following steps in Radiance/SPWeb prior to
closing the case:
o Select "Field Change Order" in the REFERENCE TYPE field.
o Enter FCO ID number in the REFERENCE ID field.
For example; A0257-1.
If possible, include additional details in the REFERENCE SUMMARY field
(ie. Upgrade complete, customer declined, etc.)
Implementation Notes
--------------------
In case of "Mandatory" FCOs, Sun Services will attempt to contact
all known customers to recommend proactive implementation.
For "Controlled Proactive" FCOs, Sun Services mission critical
support teams will initiate proactive implementation efforts for
their respective accounts, as required.
For "Upon Failure" FCOs, Sun Services and partners will implement
the necessary corrective actions as the need arises.
The CIC process must be used for proactive hardware replacement
requests when an FCO is classified as "Upon Failure".
Billing Information
-------------------
Warranty: Sun will provide parts at no charge under Warranty
Service. On-Site Labor Rates are based on specified
Warranty deliverables for the affected product.
Contract: Sun will provide parts at no charge. On-Site Labor Rates
are based on the type of service contract.
Non Contract: Sun will provide parts at no charge. Installation by
Sun is available based on the On-Site Labor Rates
defined in the Price List.