| Document Audience: | INTERNAL
	ArchiveWARNING:Articles moved into the Archived collection were accurate at the "Last Update" date, but are not maintained from that date forward. | 
 As such, Sun disclaims all implied or express warranties with respect to the information contained in such articles.
| Document ID: | I0290-1 | 
| Title: | Correction to READ ME FIRST Card included in Ultra 2 Floppy drive. | 
| Copyright Notice: | Copyright © 2005 Sun Microsystems, Inc. All Rights Reserved | 
| Last Updated Date: | 1996-10-31 | 
---------------------------------------------------------------------
        - Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------  
                        FIELD INFORMATION NOTICE
           (For Authorized Distribution by Customer Service)FIN #: I0290-1
Synopsis: Correction to READ ME FIRST Card included in Ultra 2 Floppy drive.Create Date: 10/30/96
Keywords: 
Correction to READ ME FIRST Card included in Ultra 2 Floppy drive.
Product Category: Peripheral
Product Affected: 
	
	Sun Ultra 2 Series
	X6003A 	Sony 3.5" Triple Density Floppy for Ultra 2
Product Affected: 
Sun Ultra 2 Series
	X6003A 	Sony 3.5" Triple Density Floppy for Ultra 2
Parts Affected: 
370-2151-01	Sony Triple Density Floppy Black Bezel
  	F370-2151-01 	FRU, Sony Triple Density Floppy Black Bezel
	
Reference:
802-6812-10 READ ME FIRST Card included with 370-2151 FRU And X-Option
Issue Description: 
Insert card (Read Me First, 802-6812-10) included with 370-2151 FRU
drive says that the torroid cable, 530-2316, is to used only with
Sparc 5 and Sparc 20 systems. This cable MUST also be used to correct a
noise sensitivity problem with the floppy drives in any Sun system.
Corrective Action: 
Install the 530-2316-XX cable per the installation instructions on the
READ ME FIRST card included with the 370-2151 FRU when replacing a floppy
drive in any Sun system.
Comments: 
It is the floppy drive's lack of immunity to noise that requires this
filter cable.
 
---------------------------------------------------------------------------
All released FINs and FCOs can be accessed internally on the SunWeb
using your favorite network browser as follows:
* Access the top level URL of http://sunservice.corp
* From there, follow the hyperlink path of "SunSolve Online" and click
  on "Advanced Search" to query or browse the FIN and FCO data
  collections.
Supporting documents for FIN/FCOs can be found on Edist.  Edist can be 
accessed internally at the following URL: http://edist.corp/.
 
* From there, follow the hyperlink path of "SunService Documentation" and
  click on "FIN & FCO attachments", then choose the apropriate folder,
  FIN or FCO.  This will display supporting directories/files for FINs
  or FCOs.
--------------------------------------------------------------------------
General:
________
Send questions or comments to finfco-manager@cte.Corp
---------------------------------------------------------------------------