Document Audience: | INTERNAL
Archive
| WARNING:Articles moved into the Archived collection were accurate at the "Last Update" date, but are not maintained from that date forward.
As such, Sun disclaims all implied or express warranties with respect to the information contained in such articles.
Document ID: | I0345-2 |
Title: | Ultra 2 Model 1300 UPA Bus Terminator Module recommended on uni-processor models. |
Copyright Notice: | Copyright © 2005 Sun Microsystems, Inc. All Rights Reserved |
Last Updated Date: | 1998-01-27 |
---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------
FIELD INFORMATION NOTICE
(For Authorized Distribution by SunService)
FIN #: I0345-2
Synopsis: Ultra 2 Model 1300 UPA Bus Terminator Module recommended on uni-processor models.Create Date: Jan/26/98
Keywords:
Ultra 2 Model 1300 UPA Bus Terminator Module recommended on uni-processor models.
Product Category: System
Product Affected:
Ultra 2 Model 1300
Ultra Enterprise 2 Model 1300
X1192A Ultra 2 300Mhz CPU Module
UG-M1XXX-M1300 Upgrade, Ultra 2 300Mhz CPU Module
Parts Affected:
501-3132-12 or lower Ultra 2 Motherboard Assembly
501-4196-XX Ultra 2 300Mhz CPU Module
References:
ECO# WO_11226
PROBLEM DESCRIPTION:
Engineering has released a UPA bus terminator module for Ultra 2 model
1300 single processor configured systems. This terminator minimizes
UPA bus signal distortion on Ultra 2 Model 1300 motherboards, P/N
501-3132-12 or lower. An unterminated UPA bus may exhibit noise
problems in very high intensity UPA bus activity applications.
s
may include CPU ECache data parity errors, ECC errors, async data
errors or hangs. Option X1192A is NOT structured with this terminator
and problems may occur in single CPU Ultra 2 Model 1300 system if the
terminator is NOT installed. The intention for Option X1192A is for
adding a second CPU to an existing system, NOT for CPU upgrades in uni-
processor systems.
Subsequently customers who order the Option X1192A as opposed to the
Upgrade kit UG-M1XXX-M1300, and exhibit the UPA bus signal distortion
symptoms, contact SunService logistics and request the UPA bus
terminator module, Thus SunSerice Logistics is experiencing a heavy
demand for UPA bus terminators.Issue Description:
Engineering has released a UPA bus terminator module for Ultra 2 model
1300 single processor configured systems. This terminator minimizes
UPA bus signal distortion on Ultra 2 Model 1300 motherboards, P/N
501-3132-12 or lower. An unterminated UPA bus may exhibit noise
problems in very high intensity UPA bus activity applications. Symptoms
may include CPU ECache data parity errors, ECC errors, async data
errors or hangs. Option X1192A is NOT structured with this terminator
and problems may occur in single CPU Ultra 2 Model 1300 system if the
terminator is NOT installed. The intention for Option X1192A is for
adding a second CPU to an existing system, NOT for CPU upgrades in uni-
processor systems.
Subsequently customers who order the Option X1192A as opposed to the
Upgrade kit UG-M1XXX-M1300, and exhibit the UPA bus signal distortion
symptoms, contact SunService logistics and request the UPA bus
terminator module, Thus SunSerice Logistics is experiencing a heavy
demand for UPA bus terminators.
Corrective Action:
Information only, no action required. UPA bus terminator modules (PN
501-4843-01) are being shipped with Ultra 2 300Mhz CPU upgrades.
Customers seeking to obtain a Terminator module due to an incorrect
X-Option order, should contact their Sales Representative to obtain
one, and NOT request a Terminator module through SunService Logistics
channels.
Comments:
This FIN is being released as information only and as such does not
require any activity on the part of any SunService departments or field
functions.
--------------------------------------------------------------------------
SunWeb Access:
______________
All released FINs and FCOs can be accessed internally on the SunWeb using
your favorite network browser as follows:
* Access the top level URL of http://cte.corp/FIN_FCO/
* From there, select the appropriate link to query or browse the FIN and
FCO Homepage collections.
Supporting documents for FINs/FCOs can be found on the Edist Website. The
Edist Website can be accessed internally at the following URL:
http://edist.corp/
* From there, follow the hyperlink path of "SunService Documentation" and
choose the appropriate folder, FIN or FCO. This will display supporting
directories/files for FINs or FCOs.
--------------------------------------------------------------------------
General:
________
Send questions or comments to finfco-manager@cte.Corp
---------------------------------------------------------------------------