Document Audience: | INTERNAL
Archive
| WARNING:Articles moved into the Archived collection were accurate at the "Last Update" date, but are not maintained from that date forward.
As such, Sun disclaims all implied or express warranties with respect to the information contained in such articles.
Document ID: | I0399-2 |
Title: | Updated FIN.-Misdiagnosed Power Supply Failures on Enterprise 450 Systems. |
Copyright Notice: | Copyright © 2005 Sun Microsystems, Inc. All Rights Reserved |
Last Updated Date: | 1998-07-16 |
---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------
FIELD INFORMATION NOTICE
(For Authorized Distribution by SunService)
FIN #: I0399-2
Synopsis: Updated FIN.-Misdiagnosed Power Supply Failures on Enterprise 450 Systems.Create Date: Jul/15/98
Keywords:
Updated FIN.-Misdiagnosed Power Supply Failures on Enterprise 450 Systems.
Top FIN/FCO Report: No
Products Reference: E450 Power Supply Memory Latch Function
Product Category: Server / Power
Product Affected:
Systems Affected
----------------
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
- E450 ALL Ultra Enterprise 450 -
- E450 ALL Ultra 450 -
Parts Affected:
Part Number Description Model
----------- ----------- -----
300-1302-0X 560W power supply -
300-1359-0X 605W power supply -
References:
MANUAL: 805-0429-10 Ultra Enterprise 450 Server Owner's guide
MANUAL: 805-0430-10 Sun Ultra 450 Workstation Owner's Guide
ECO: WO_11640
FIN: I0399-1
Issue Description:
Serial Number
------ -------- ----- ----------- -------------
- E450 ALL Ultra Enterprise 450 -
- E450 ALL Ultra 450 -
PART NUMBERS AFFECTED:
Part Number Description Model
----------- ----------- -----
300-1302-0X 560W power supply -
300-1359-0X 605W power supply -
REFERENCES:
MANUAL: 805-0429-10 Ultra Enterprise 450 Server Owner's guide
MANUAL: 805-0430-10 Sun Ultra 450 Workstation Owner's Guide
ECO: WO_11640
FIN: I0399-1
PROBLEM DESCRIPTION
The power supply used on Ultra 450 workstations and Ultra Enterprise
450 servers has a memory latch function that allows the power supply
to "remember" its last power ON/OFF state in response to a power out-
age or removal of the AC power cord. This feature allows the power
supply to resume operation automatically once power is restored. It
also enables hot-swapping of power supplies.
Under some circumstances, this feature can be misdiagnosed as a power
supply failure. For Example, If you remove a power supply from a system
that is powered off and attempt a hot-plug installation into a system
that is powered on, the power supply will remain in the Off state. This
should not be interpreted as a power supply failure.
*This Updated FIN has been released with the intent to provide instruc-
tions for E450 power supply maintenance in such instances where Power
Management has been configured.
Implementation:
---
| | MANDATORY (Fully Pro-Active)
---
---
| | CONTROLLED PRO-ACTIVE (per Sun Geo Plan)
---
---
| X | REACTIVE
---
Corrective Action:
Customers and Field Service Representatives that encounter the above
mentioned E450 Power Supply Memory Latch Function are advised of the
following:
1. To�activate the power supply, simply turn the front panel keyswitch
from the Power-On position to the Diagnostics position, and then back
to the Power-On position.
2. Alternatively, you may press the Power-On key on a Sun Type-5 keyboard
attached to the system if they do not have "power manager" configured.
For a system that has power management configured, pressing the Power-On
key will initiate the suspend function. A window appears on the screen
that lets you confirm or cancel the suspend request. In this scenario,
users should cancel the suspend request. Even though the request is
canceled, the power supply's internal memory latch still gets reset to
the ON state, as intended.
*NOTE: This scenario would only apply to the Ultra 450 workstation, as
power management is not supported on the Enterprise 450 server
(by default, Power management is disabled on the E450 server).
Comments:
--------------------------------------------------------------------------
Implementation Footnote:
________________________
i) In case of MANDATORY FINs, Enterprise Services will attempt to contact all
affected customers to recommend implementation of the FIN.
ii) For CONTROLLED PROACTIVE FINs, Enterprise Services mission critical support
teams will recommend implementation of the FIN (to their respective
accounts),
at the convenience of the customer.
iii) For REACTIVE FINs, Enterprise Services will implement the FIN as the need
arises.
--------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network
browser as follows:
SunWeb Access:
______________
* Access the top level URL of http://cte.corp/FIN_FCO/
* From there, select the appropriate link to query or browse the FIN and
FCO Homepage collections.
Supporting documents for FIN/FCOs can be found on Edist. Edist can be
accessed internally at the following URL: http://edist.corp/.
* From there, follow the hyperlink path of "SunService Documentation" and
click on "FIN & FCO attachments", then choose the appropriate folder, FIN or
FCO. This will display supporting directories/files for FINs or FCOs.
Internet Access:
_______________
* Access the top level URL of https://infoserver.Sun.COM
--------------------------------------------------------------------------
General:
________
Send questions or comments to finfco-manager@cte.Corp
---------------------------------------------------------------------------