Document Audience: | INTERNAL
Archive
| WARNING:Articles moved into the Archived collection were accurate at the "Last Update" date, but are not maintained from that date forward.
As such, Sun disclaims all implied or express warranties with respect to the information contained in such articles.
Document ID: | I0428-1 |
Title: | Existing Power Cord for US E10000 Systems is too long to meet UL requirements. |
Copyright Notice: | Copyright © 2005 Sun Microsystems, Inc. All Rights Reserved |
Last Updated Date: | 1998-09-24 |
---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------
FIELD INFORMATION NOTICE
(For Authorized Distribution by SunService)
FIN #: I0428-1
Synopsis: Existing Power Cord for US E10000 Systems is too long to meet UL requirements.Create Date: Sep/21/98
Keywords:
Existing Power Cord for US E10000 Systems is too long to meet UL requirements.
Top FIN/FCO Report: Yes
Products Reference: E10000 Power Cable
Product Category: Server / Power
Product Affected:
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
Systems Affected
----------------
- E10000 - Ultra Enterprise 10000 -
X-Options Affected
------------------
X3850A - - Power Cord, US Version -
Parts Affected:
Part Number Description Model
----------- ----------- -----
422-6543-001 CABLE ASSY,AC MAIN POWER, U.S. -
530-2379-01 CABLE ASSY,AC MAIN POWER, U.S. -
References:
N/A
Issue Description:
The Cable Assy (p/n: 422-6543-001 R01 and 530-2379-01) is too long
to meet UL requirements for applications in the USA. The cable Assy
was incorrectly approved by UL staff when originally presented. Since
that time, it has been discovered that the 20ft length is actually in
violation of the UL requirement of 14.75ft max.
A shorter replacement cable has been designed (p/n: 530-2503-01), and
is to be used effective immediately. This FIN serves to alert the
field/sales staff of this new requirement and to make sure the implica-
tions are understood with regard to site planning/location of input
power, etc.
The Cable that is in violation of the UL spec is clearly marked with
the part number: 422-6543-001 R0X or 530-2379-01, and is 20ft long
+/- 0.5 ft. All existing installs will have the short length require-
ment waived, but the shorter cable assy is required for all U.S. sales
contracts signed after the [proposed] date of 09/15/98. This date has
yet to be officially accepted by UL.
All systems whose sales contracts are signed after 09/15/98 will need
to be equipped with short Cable Assy (mfg p/n: 530-2503-01, mkt p/n:
x3865A).
Implementation:
---
| | MANDATORY (Fully Pro-Active)
---
---
| X | CONTROLLED PRO-ACTIVE (per Sun Geo Plan)
---
---
| | REACTIVE (As Required)
---
Corrective Action:
All U.S. systems with sales contracts signed after 09/15/98 must be
equipped with the new Cable Assy (mfg p/n: 530-2503-01, mkt p/n: x3865A).
All other systems will be allowed to be equipped with the 20ft cable
(p/n: 422-6543-001). A hardware swap of all for existing US systems
with sales contracts signed before 09/15/98 will not be required, pending
UL's acceptance of this cut-in date.
Comments:
All U.S. systems with sales contracts signed after 09/15/98 must be equipped
with the new Cable Assy (mfg p/n: 530-2503-01, mkt p/n: x3865A). All other
systems will be allowed to be equipped with the 20ft cable (p/n: 422-6543-
001). A hardware swap of all for existing US systems with sales contracts
signed before 09/15/98 is NOT required.
--------------------------------------------------------------------------
Implementation Footnote:
________________________
i) In case of MANDATORY FINs, Enterprise Services will attempt to contact
all affected customers to recommend implementation of the FIN.
ii) For CONTROLLED PROACTIVE FINs, Enterprise Services mission critical sup-
port teams will recommend implementation of the FIN (to their respective
accounts), at the convenience of the customer.
iii) For REACTIVE FINs, Enterprise Services will implement the FIN as the need
arises.
--------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network
browser as follows:
SunWeb Access:
______________
* Access the top level URL of http://cte.corp/FIN_FCO/
* From there, select the appropriate link to query or browse the FIN and
FCO Homepage collections.
Supporting documents for FIN/FCOs can be found on Edist. Edist can be
accessed internally at the following URL: http://edist.corp/.
* From there, follow the hyperlink path of "SunService Documentation" and
click on "FIN & FCO attachments", then choose the appropriate folder, FIN or
FCO. This will display supporting directories/files for FINs or FCOs.
Internet Access:
_______________
* Access the top level URL of https://infoserver.Sun.COM
--------------------------------------------------------------------------
General:
________
Send questions or comments to finfco-manager@cte.Corp
---------------------------------------------------------------------------