Title:Sun Enterprise 250 Server 400MHZ CPU Modules may sustain damage during installation.
Copyright Notice:Copyright © 2005 Sun Microsystems, Inc. All Rights Reserved
Last Updated Date:1999-05-22

---------------------------------------------------------------------
        - Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------  
                        FIELD INFORMATION NOTICE
                  (For Authorized Distribution by SunService)
FIN #: I0485-1
Synopsis: Sun Enterprise 250 Server 400MHZ CPU Modules may sustain damage during installation.
Create Date: Apr/08/99
Keywords: 

Sun Enterprise 250 Server 400MHZ CPU Modules may sustain damage during installation.

Top FIN/FCO Report: No
Products Reference: E250 400MHZ CPU Installation
Product Category: Server / System CPU Module
Product Affected: 
Mkt_ID   Platform   Model   Description   Serial Number
------   --------   -----   -----------   -------------
Systems Affected
----------------

  -      A26        ALL     Enterprise 250            -
         
X-Options Affected
------------------

X1194A   -          -       OPT 400MHZ/2MB PROCESSOR  -
Parts Affected: 
Part Number   Description                Model
-----------   -----------                -----
501-5237-0X   ASSY,SAPH-BLK,2M,400,MODULE  -
References: 
MANUAL: 805-5160-10  Enterprise 250 Owners Manual
MEDIA:  724-2794-02 Enterprise 250 ShowMe How
Issue Description: 
During the installation or upgrade of 400MHZ CPU Modules (X1194A)
of Sun Enterprise 250 systems, the CPU modules may become damaged
upon insertion into the plastic module guides.

This potential problem is due to a small number of Enterprise 250 
systems that may have been shipped with the black plastic CPU module 
guides within the module cage on the hurdle board, could have a  
deformity on the spring face or reached the max. spec. condition 
whereby the module comes into contact with guide causing component 
damage (typically to L1401).
Implementation: 
---
        |   |   MANDATORY (Fully Pro-Active)
         ---    
         
  
         ---
        |   |   CONTROLLED PRO-ACTIVE (per Sun Geo Plan) 
         --- 
         
                                
         ---
        | X |   REACTIVE (As Required)
         ---
Corrective Action: 
Customers and Field Service Representatives either installing or 
upgrading Enterprise 250 400mhz CPU Modules (X1194A) can avoid 
possible damage to the 400mhz CPUs by following the recommendation 
shown below:

    Each X1194A option includes a pair of new CPU guides, CPU
    module and a Read Me First Doc.  Follow the recommendation
    in the Read Me First Doc. and install to new CPU guides in-
    cluded with the X-Option prior to installing the new 400mhz
    CPU Module(s).
Comments: 
--------------------------------------------------------------------------
Implementation Footnote: 
________________________

i)   In case of MANDATORY FINs, Enterprise Services will attempt to contact   
     all affected customers to recommend implementation of the FIN. 
        

ii)  For CONTROLLED PROACTIVE FINs, Enterprise Services mission critical sup-   
     port teams will recommend implementation of the FIN (to their respective 
     accounts), at the convenience of the customer. 


iii) For REACTIVE FINs, Enterprise Services will implement the FIN as the need  
     arises.

-----------------------------------------------------------------------
 
All released FINs and FCOs can be accessed using your favorite network 
browser as follows:
 
SunWeb Access: 
______________
 
* Access the top level URL of http://cte.ebay/FIN_FCO/

* From there, select the appropriate link to query or browse the FIN and
  FCO Homepage collections.
 
SunSolve Online Access:
_______________________
 
* Access the SunSolve Online URL at http://sunsolve.Corp/

* From there, select the appropriate link to browse the FIN or FCO index.

Supporting Documents:
____________________
 
Supporting documents for FIN/FCOs can be found on Edist.  Edist can be 
accessed internally at the following URL: http://edist.corp/.
  
* From there, follow the hyperlink path of "SunService Documentation" and 
  click on "FIN & FCO attachments", then choose the appropriate folder,  
  FIN or FCO.  This will display supporting directories/files for FINs or
  FCOs.
   
Internet Access:
_______________
 
* Access the top level URL of https://infoserver.Sun.COM
 
--------------------------------------------------------------------------
    
General:
________

Send questions or comments to finfco-manager@cte.ebay

---------------------------------------------------------------------------
Statusinactive