Document Audience: | INTERNAL |
Document ID: | I0519-1 |
Title: | Networker may attempt to position a DLT7000 volume to read the label before the drive has completed the load sequence |
Copyright Notice: | Copyright © 2005 Sun Microsystems, Inc. All Rights Reserved |
Update Date: | 1999-09-16 |
---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------
FIELD INFORMATION NOTICE
(For Authorized Distribution by SunService)
FIN #: I0519-1
Synopsis: Networker may attempt to position a DLT7000 volume to read the label before the drive has completed the load sequenceCreate Date: Sep/16/99
Keywords:
Networker may attempt to position a DLT7000 volume to read the label before the drive has completed the load sequence
Top FIN/FCO Report: No
Products Reference: default load_sleep value
Product Category: Storage / SW Admin; Software / Unbundled;
Product Affected:
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
Systems Affected
----------------
- ANYSYS - System Platform Independent -
X-Options Affected
------------------
X6063A - - 35-70GB DLT 7000 for L1800 or L3500 -
X6073A - - StorEdge L1800 w 2 DLT 7000 drives -
X6074A - - StorEdge L1800 w 4 DLT 7000 drives -
X6075A - - StorEdge L3500 w 2 DLT 7000 drives -
X6076A - - StorEdge L3500 w 7 DLT 7000 drives -
G-XLIBDLT1-1TB - StorEdge L1000 Library Deskside -
SG-XLIBDLT4-1TB - StorEdge L1000 Library Deskside -
SG-XLIBDLT1R-1TB - StorEdge L1000 Library Rackmount -
SG-XLIBDLT4R-1TB - StorEdge L1000 Library Rackmount -
SG-XTAPDLT1-1TB - StorEdge DLT 7000 Drive for L1000 -
X6073A - - StorEdge L1800 w 2 DLT 7000 drives -
X6074A - - StorEdge L1800 w 4 DLT 7000 drives -
X6075A - - StorEdge L3500 w 2 DLT 7000 drives -
X6076A - - StorEdge L3500 w 7 DLT 7000 drives -
X6063A - - 5-70GB DLT 7000 for L1800 or L3500 -
SG-XLIBDLT1-280G - - StorEdge Autoloader (Deskside) -
SG-XLIBDLT2-280G - - StorEdge Autoloader (Rackmount) -
Parts Affected:
Part Number Description Model
----------- ----------- -----
794-7575-01 SBU SERVER EDITION ALL
References:
N/A
Issue Description:
The DLT7000 has a minimum load time of 48 seconds (previously written)
this time may be longer if the tape is blank. The networker product
has no understanding of the DLT's "time to load" or for that matter,
any other tape library's "time to load" value, and may attempt to
position the volume to read the label prior to the drive being at BOT.
Should this be the case, one of the following errors may be returned
during the mount request:
tape: verify label operation in progress
media warning:tape opening io error
open error
Should this type of problem exist, first check the tape library
documentation for the manufacturers quoted time to load the tape to
the BOT mark. This is the time to use plus a 10% safety margin for
equipment variations since all equivalent tape libraries are not
exactly equal in mechanical functioning. For example, if the
manufacturer states that it takes 85 seconds to load the tape to the
BOT mark, then set the value of the load_sleep variable to 85 seconds
plus an additional 8.5 seconds or rounding off, set the value to 94
seconds. This should allow the tape drive to load the tape and advance
to the BOT and be ready for either the read or write function to occur
normally.
Implementation:
---
| | MANDATORY (Fully Pro-Active)
---
---
| | CONTROLLED PRO-ACTIVE (per Sun Geo Plan)
---
---
| x | REACTIVE (As Required)
---
Corrective Action:
Enterprise Customers and Authorized Service Representatives may avoid
the above mentioned Networker problem by following the recommendation
shown below:
1. Set the load_sleep parameter to a value in seconds.
For example, "load_sleep=300" will cause nsrjb to wait for 300
seconds before attempting the access the device.
The default value is insufficient and will not allow the drive time to
complete the tape load process.
If this option is not set (!load_sleep), then the default value is 0
seconds.
This delay was added to NetWorker for devices which return
asynchronously from the load operation before the device is ready.
Use the NetWorker Administration GUI (nwadmin) to set this parameter.
For Example in SBU 5.1.
>From the nwadmin GUI
Select Media =v
v> Jukeboxes => View => Details => Jukebox options
Type "load_sleep=n" where n is the number of seconds or use the
up/down pointers to change the value
For Example in SBU 5.5.1
>From the nwadmin GUI
Select Media =v
v> Jukeboxes => View => Details => load sleep
Type load sleep column "n" where n is the number of seconds or
use the up/down pointers to change the value
Comments:
--------------------------------------------------------------------------
Implementation Footnote:
i) In case of MANDATORY FINs, Enterprise Services will attempt to
contact all affected customers to recommend implementation of
the FIN.
ii) For CONTROLLED PROACTIVE FINs, Enterprise Services mission critical
support teams will recommend implementation of the FIN (to their
respective accounts), at the convenience of the customer.
iii) For REACTIVE FINs, Enterprise Services will implement the FIN as the
need arises.
----------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network
browser as follows:
SunWeb Access:
--------------
* Access the top level URL of http://sdpsweb.ebay/FIN_FCO/
* From there, select the appropriate link to query or browse the FIN and
FCO Homepage collections.
SunSolve Online Access:
-----------------------
* Access the SunSolve Online URL at http://sunsolve.Corp/
* From there, select the appropriate link to browse the FIN or FCO index.
Supporting Documents:
---------------------
* Supporting documents for FIN/FCOs can be found on Edist. Edist can be
accessed internally at the following URL: http://edist.corp/.
* From there, follow the hyperlink path of "Enterprise Services Documenta-
tion" and click on "FIN & FCO attachments", then choose the appropriate
folder, FIN or FCO. This will display supporting directories/files for
FINs or FCOs.
Internet Access:
----------------
* Access the top level URL of https://infoserver.Sun.COM
--------------------------------------------------------------------------
General:
--------
* Send questions or comments to finfco-manager@Sun.COM
---------------------------------------------------------------------------