Document Audience: | INTERNAL |
Document ID: | I0533-1 |
Title: | A minute quantity of ST39102FC 9GB FC-AL disk drives may be susceptible to low amplitude head failures. |
Copyright Notice: | Copyright © 2005 Sun Microsystems, Inc. All Rights Reserved |
Update Date: | 1999-11-19 |
---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------
FIELD INFORMATION NOTICE
(For Authorized Distribution by SunService)
FIN #: I0533-1
Synopsis: A minute quantity of ST39102FC 9GB FC-AL disk drives may be susceptible to low amplitude head failures.Create Date: Nov/19/99
Keywords:
A minute quantity of ST39102FC 9GB FC-AL disk drives may be susceptible to low amplitude head failures.
Top FIN/FCO Report: No
Products Reference: ST39102FC head failures
Product Category: Storage / Disk;
Product Affected:
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
Systems Affected
----------------
- E3000 ALL Ultra Enterprise 3000 -
- E3500 ALL Ultra Enterprise 3500 -
- E4000 ALL Ultra Enterprise 4000 -
- E4500 ALL Ultra Enterprise 4500 -
- E5000 ALL Ultra Enterprise 5000 -
- E5500 ALL Ultra Enterprise 5500 -
- E6000 ALL Ultra Enterprise 6000 -
- E6500 ALL Ultra Enterprise 6500 -
- E10000 ALL Ultra Enterprise 10000 -
X-Options Affected
------------------
SG-ARY520A-200G - - 200GB Sun StorEdge A5200
SG-ARY521A-200G - - 200GB Sun StorEdge A5200
SG-ARY521A-200GR4 - - 200GB Sun StorEdge A5200
SG-ARY521A-200GR5 - - 200GB Sun StorEdge A5200
SG-ARY522A-200G - - 200GB Sun StorEdge A5200
SG-ARY522A-200GR4 - - 200GB Sun StorEdge A5200
SG-ARY523A-1200G - - 1200GB Sun StorEdge A5200
SG-ARY523A-200G - - 200GB Sun StorEdge A5200
SG-ARY523A-400G - - 400GB Sun StorEdge A5200
SG-ARY523A-800G - - 800GB Sun StorEdge A5200
SG-XARY520A-200G - - 200GB Sun StorEdge A5200
SG-XARY520A-63G - - 63GB Sun StorEdge A5200
SG-XARY521A-200G - - 200GB Sun StorEdge A5200
SG-XARY522A-200G - - 200GB Sun StorEdge A5200
SG-XARY523A-1200G - - 1200GB Sun StorEdge A5200
SG-XARY523A-400G - - 400GB Sun StorEdge A5200
SG-XARY523A-800G - - 800GB Sun StorEdge A5200
SG-XARY541A-400G - - 400GB Sun StorEdge A5200
Parts Affected:
Part Number Description Model
----------- ----------- -----
540-3869-0X ASSY,9GB FC-AL 10K,W/SPUD BRKT ST39102FC
(SCSI Devices)
Type Vendor Model Serial Number(Min) Serial Number(Max) Firmware
---- ------ ------- ------------------ ------------------ --------
Disk Seagate ST39102FC 9914 9919 -
References:
N/A
Issue Description:
A failure mechanism has been identified as low amplitude head failures
due to scratches across the Pole Tip of the head. Pole Tip is the
electrical area of the head which detects the magnetic signal from the
disk.
The most frequent symptoms are error messages similar to below:
Drive not ready and/or drive has excessive G-list adds.
NOTE: This failure mode requires failure analysis to verify root cause
as symptom messages do not 100% correlate to "head scratch" root
cause. These same error messages can have many other root causes,
failure analysis is required to validate.
The magnitude of exposure for this failure mechanism is small and reduces
overtime. The Annual Failure Rate (AFR) exposure has been measured
to be at 0.25%. The drive's specification for AFR is 1.09% which equals 800K
hours MTBF and this drive is presently measured in the field at 0.98%,
therefore, the drive is meeting the field reliability metric. It has been
sized that less than 100 drives out of a risk population of 6000 drives have
this failure mechanism and the majority of this 100 drive exposure have
already been removed from the field population.
Identification of a potential drive exhibiting this failure mechanism and
symptom is by Sun date code range of 9914-9919. This date code can be viewed
via inquiry to the configuration in question by means of Health Check and/or
Explorer Script.
Seagate has implemented a head wafer tooling and process corrective action
starting with drive date code 9920.
Implementation:
---
| | MANDATORY (Fully Pro-Active)
---
---
| | CONTROLLED PRO-ACTIVE (per Sun Geo Plan)
---
---
| X | REACTIVE (As Required)
---
Corrective Action:
All Authorized Enterprise Field Service Representatives that replace
ST39102FC disk(s) should note the following recommendations:
Enterprise Services Field Service Representative Instructions:
1. If an A5x00 customer site is reporting a high 540-3869-XX disk
replacement rate:
a: Route all disk failures (540-3869-0X) through the Sun Customer
Quality RCA process for failure analysis. RCA request must be
filled out completely and accompanied by an explorer script(s).
b: A swap out Action Plan will be initiated if the all of the following
metrics are triggered:
- Through the RCA/FFA process the root cause is identified as Head Scratch.
- The Site Hard Disk Drive failure rate exceeds the AFR goal.
- Drive model number ST39102FC have date codes 9914-9919.
Comments:
--------------------------------------------------------------------------
Implementation Footnote:
i) In case of MANDATORY FINs, Enterprise Services will attempt to
contact all affected customers to recommend implementation of
the FIN.
ii) For CONTROLLED PROACTIVE FINs, Enterprise Services mission critical
support teams will recommend implementation of the FIN (to their
respective accounts), at the convenience of the customer.
iii) For REACTIVE FINs, Enterprise Services will implement the FIN as the
need arises.
----------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network
browser as follows:
SunWeb Access:
--------------
* Access the top level URL of http://sdpsweb.ebay/FIN_FCO/
* From there, select the appropriate link to query or browse the FIN and
FCO Homepage collections.
SunSolve Online Access:
-----------------------
* Access the SunSolve Online URL at http://sunsolve.Corp/
* From there, select the appropriate link to browse the FIN or FCO index.
Supporting Documents:
---------------------
* Supporting documents for FIN/FCOs can be found on Edist. Edist can be
accessed internally at the following URL: http://edist.corp/.
* From there, follow the hyperlink path of "Enterprise Services Documenta-
tion" and click on "FIN & FCO attachments", then choose the appropriate
folder, FIN or FCO. This will display supporting directories/files for
FINs or FCOs.
Internet Access:
----------------
* Access the top level URL of https://infoserver.Sun.COM
--------------------------------------------------------------------------
General:
--------