Document Audience: | INTERNAL |
Document ID: | I0666-1 |
Title: | Replacement of defective power supplies in E220R/E420R systems |
Copyright Notice: | Copyright © 2005 Sun Microsystems, Inc. All Rights Reserved |
Update Date: | 2001-07-24 |
---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------
FIELD INFORMATION NOTICE
(For Authorized Distribution by SunService)
FIN #: I0666-1
Synopsis: Replacement of defective power supplies in E220R/E420R systemsCreate Date: May/25/01
Keywords:
Replacement of defective power supplies in E220R/E420R systems
Top FIN/FCO Report: No
Products Reference: Hot Swappable Power Supply
Product Category: Server / Service
Product Affected:
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
Systems Affected
----------------
- E220R ALL Ultra Enterprise 220R -
- E420R ALL Ultra Enterprise 420R -
X-Options Affected
------------------
- - - - -
Parts Affected:
Part Number Description Model
----------- ----------- -----
300-1449-02 PS,380 WATT,5OUTPUT,HOT PLUG -
300-1449-03 PS,380 WATT,5OUTPUT,HOT PLUG -
References:
BugId: 4307681 - E420R/E220R Redundant PSUs lock into a fail state
after A/C i/p interruption.
4449598 - Power Supply Unit becomes no output on E420R.
ECO: WO_18802
WO_20661
ESC: 524659
530248
MANUAL: 806-1080-10: Sun Enterprise 420R Server Service Manual
806-1081-10: Sun Enterprise 220R Server Service Manual
Issue Description:
Improper service procedures with the E220R/E420R power supplies could
result in system downtime. In addition, under certain circumstances,
the hot swapping functionality for the redundant power supplies may
fail.
Multiple power supply failure issues in E220R or E420R systems have
been reported from the field. Based on an evaluation of reported
failure modes and testing of quarantined power supplies returned from
the field, two issues have become apparent.
--------
|ISSUE 1:|
--------
False error conditions or system crash/downtime could result from rapid
seating and unseating of power supplies as well as rapid unseating and
reseating of the power cord or brief interruptions in power. Power
supplies will also shut down automatically in response to certain
over-temperature and power fault conditions.
This issue pertains to BOTH the 300-1449-02 (with or without ECO label
attached) and the 300-1449-03 power supplies.
--------
|ISSUE 2:|
--------
Failure of the operational power supply is caused by an overly
sensitive fan fail circuit detecting a 12v droop. No matter how long
you wait, once you insert the second supply, load sharing begins and a
failure of the operational supply is possible. This failure has been
seen in a very small percentage of power supplies.
Power supply part number 300-1449-02 is affected by Issue 2.
Approximately 280,000 of these power supplies have been shipped in
E220R/E420R systems as FRUs.
A permanent fix for issue 2 has been incorporated into stocked
inventory of the 300-1449-02 and is identifiable by a label with
WO_20661 on it. In addition, the 300-1449-03 has a redesigned daughter
board in it which has eliminated the sensitive fan circuit.
Please follow the procedures in the Corrective Action section when
replacing a power supply in any E220R/E420R system.
Implementation:
---
| | MANDATORY (Fully Pro-Active)
---
---
| | CONTROLLED PRO-ACTIVE (per Sun Geo Plan)
---
---
| X | REACTIVE (As Required)
---
Corrective Action:
The following recommendation is provided as a guideline for authorized
Enterprise Services Field Representatives and Warranty Customers who
may be encountering the above mentioned problem.
NOTE: These procedures should only be followed when a power supply
failure has been experienced and requires replacement. This
FIN does not recommend or authorize proactive replacement of
power supplies.
--------
|ISSUE 1:|
--------
When removing a hot-swappable power supply, do not dis-engage and
re-engage the power supply in rapid succession. Always remove a power
supply completely before re-inserting the same power supply or a
replacement power supply.
Wait at least 10 seconds after power-on of a redundant power supply
before removing power from the primary power supply or before removing
the primary power supply. It takes a minimum of three seconds for the
redundant power supply to come up to regulation.
See Chapter 5 in the Sun Enterprise 420R Server Service Manual or the
Sun Enterprise 220R Server Service Manual for details about removing
and replacing power supplies.
--------
|ISSUE 2:|
--------
When replacing a defective E220R/E420 power supply, replace the
defective power supply with a modified -02 (labeled with ECO
WO_20661) or a -03 power supply. Be aware that in a small percentage
of cases, hot swapping will not work and the original operating power
supply, if version -02, may shut down. This could cause the system to
lose all power and the operating systems and any applications will halt.
To prevent this potential occurrence from causing unplanned system
downtime and/or filesystem damage for mission critical systems, it is
advisable to bring down the OS in an orderly manner before replacing
the defective power supply.
If the original power supply does shut down, unplug the AC power cord,
wait at least 10 seconds, and then plug the cord in.
Comments:
None
----------------------------------------------------------------------------
Implementation Footnote:
i) In case of MANDATORY FINs, Enterprise Services will attempt to
contact all affected customers to recommend implementation of
the FIN.
ii) For CONTROLLED PROACTIVE FINs, Enterprise Services mission critical
support teams will recommend implementation of the FIN (to their
respective accounts), at the convenience of the customer.
iii) For REACTIVE FINs, Enterprise Services will implement the FIN as the
need arises.
----------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network
browser as follows:
SunWeb Access:
--------------
* Access the top level URL of http://sdpsweb.ebay/FIN_FCO/
* From there, select the appropriate link to query or browse the FIN and
FCO Homepage collections.
SunSolve Online Access:
-----------------------
* Access the SunSolve Online URL at http://sunsolve.Corp/
* From there, select the appropriate link to browse the FIN or FCO index.
Supporting Documents:
---------------------
* Supporting documents for FIN/FCOs can be found on Edist. Edist can be
accessed internally at the following URL: http://edist.corp/.
* From there, follow the hyperlink path of "Enterprise Services Documenta-
tion" and click on "FIN & FCO attachments", then choose the appropriate
folder, FIN or FCO. This will display supporting directories/files for
FINs or FCOs.
Internet Access:
----------------
* Access the top level URL of https://infoserver.Sun.COM
--------------------------------------------------------------------------
General:
--------
* Send questions or comments to finfco-manager@Sun.COM
---------------------------------------------------------------------------