Document Audience: | INTERNAL |
Document ID: | I0838-1 |
Title: | E10K cannot boot from the network using Dual Fast Ethernet + Dual SCSI PCI Adapter |
Copyright Notice: | Copyright © 2005 Sun Microsystems, Inc. All Rights Reserved |
Update Date: | 2002-06-12 |
---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------
FIELD INFORMATION NOTICE
(For Authorized Distribution by SunService)
FIN #: I0838-1
Synopsis: E10K cannot boot from the network using Dual Fast Ethernet + Dual SCSI PCI AdapterCreate Date: Jun/12/02
Keywords:
E10K cannot boot from the network using Dual Fast Ethernet + Dual SCSI PCI Adapter
SunAlert: Yes
Top FIN/FCO Report: No
Products Reference: Ultra Enterprise 10000
Product Category: Server / Service
Product Affected:
Systems affected:
-----------------
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
- E10000 ALL Ultra Enterprise 10000 -
X-Options Affected:
-------------------
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
X2222A - ALL Sun Dual FE + Dual SCSI PCI Adapter -
Parts Affected:
Part Number Description Model
----------- ----------- -----
501-5727-03 Dual FastEthernet + Dual SCSI PCI Adapter -
References:
ECO: WO_23493
LEAP: 1954
DPCO: 298
DOC: 806-6052-10 - Dual FastEthernet and Dual SCSI/P Adapter Installation
and User's Guide.
Issue Description:
Sun Enterprise 10000 systems will fail to boot over the network from
a down rev Dual Fast Ethernet and Dual SCSI PCI Adapter. This can
lead to unexpected system downtime when attempting to perform a
network install.
The affected configuration is any E10K system with Sun part number
501-5727-03 installed. All E10K systems configured in
manufacturing with Option X2222A shipped with 501-5727-04 boards
and are not affected. The only possibility for failure exists when
Sun part number 501-5727-03 is installed as a replacement FRU.
The error message is "failed selftest error".
Root cause determined that the firmware level of the 501-5727-03 boards
will not support a network boot on an E10K. When booting from the
ethernet port that is connected to the network, the first step that
occurs is a self-test on that port. This test will fail immediately
and the system will not be able to boot.
Corrective action was made available in manufacturing by releasing the
501-5727-04 via ECO# WO_23493 as of March 12, 2002. Corrective
action was made available in Enterprise Service via LEAP# 1954 as of
April 5, 2002.
Implementation:
---
| | MANDATORY (Fully Proactive)
---
---
| | CONTROLLED PROACTIVE (per Sun Geo Plan)
---
---
| X | REACTIVE (As Required)
---
Corrective Action:
The following recommendation is provided as a guideline for authorized
Enterprise Services Field Representatives who may encounter the above
mentioned problem.
The E10K platform *only* supports the 501-5727-04 or later version of the
X2222A (Cauldron) card. When replacing this board in an E10K system, only
use FRU version 501-5727-04 or greater.
Reference the Dual FastEthernet and Dual SCSI/P Adapter Installation and
User's Guide, 806-6052-10, for the details of board installation.
Comments:
None
============================================================================
Implementation Footnote:
i) In case of MANDATORY FINs, Enterprise Services will attempt to
contact all affected customers to recommend implementation of
the FIN.
ii) For CONTROLLED PROACTIVE FINs, Enterprise Services mission critical
support teams will recommend implementation of the FIN (to their
respective accounts), at the convenience of the customer.
iii) For REACTIVE FINs, Enterprise Services will implement the FIN as the
need arises.
----------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network
browser as follows:
SunWeb Access:
--------------
* Access the top level URL of http://sdpsweb.ebay/FIN_FCO/
* From there, select the appropriate link to query or browse the FIN and
FCO Homepage collections.
SunSolve Online Access:
-----------------------
* Access the SunSolve Online URL at http://sunsolve.Corp/
* From there, select the appropriate link to browse the FIN or FCO index.
Internet Access:
----------------
* Access the top level URL of https://infoserver.Sun.COM
--------------------------------------------------------------------------
General:
--------
* Send questions or comments to finfco-manager@sdpsweb.EBay
--------------------------------------------------------------------------