Document Audience:INTERNAL
Document ID:I0903-1
Title:The propagation of SE9900 configuration diskettes from one SE9900 Subsystem to another, can result in a complete SE9900 subsystem outage.
Copyright Notice:Copyright © 2005 Sun Microsystems, Inc. All Rights Reserved
Update Date:2002-11-25

---------------------------------------------------------
            - Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------  
                        FIELD INFORMATION NOTICE
               (For Authorized Distribution by SunService)
FIN #: I0903-1
Synopsis: The propagation of SE9900 configuration diskettes from one SE9900 Subsystem to another, can result in a complete SE9900 subsystem outage.
Create Date: Nov/11/02
SunAlert: No
Top FIN/FCO Report: No
Products Reference: StorEdge 99X0 Array
Product Category: Storage / Documentation
Product Affected: 
Systems Affected:
-----------------  
Mkt_ID   Platform   Model    Description                   Serial Number
------   --------   -----    -----------                   -------------
  -       Anysys      -      System Platform Independent         -	


X-Options Affected:
-------------------
Mkt_ID   Platform   Model    Description                 Serial Number
------   --------   -----    -----------                 -------------
  -        9910      ALL     Sun StorEdge 9910 Array           -
  -        9960      ALL     Sun StorEdge 9960 Array           -
  -        9970      ALL     Sun StorEdge 9970 Array           -
  -        9980      ALL     Sun StorEdge 9980 Array           -
Parts Affected: 
Part Number      Description            Model
-----------      -----------            -----
     -                -                   -
References: 
HDS Alert: 9980V#14  
           9970V#14  
           9960#102  
           9910#77
Issue Description: 
Cloning or copying an existing Sun StorEdge 99X0 Array configuration
from one Subsystem to another using a configuration diskette may lead
to a complete outage of the second Subsystem.  When this happens, a
Define Configuration and Install operation may be required, including
blocking and re-formatting of all installed disk parity groups.  In
addition, SVP to DKC communication may fail, requiring that an initial
"bring up" operation be performed.

This issue can occur with any Sun StorEdge 99x0 (SE9900) array when an
incorrect configuration diskette is used to configure a second
Subsystem and any of the following is true:

  . The serial numbers of the 2 Subsystems are not identical (normally true).
   
  . The physical configuration of the Subsystems is mismatched. 
  
  . The microcode levels are not identical.
  
When this issue occurs, these symptoms may be noticed:

  . There may be a Service Processor (SVP) to Disk Controller (DKC)
    communication failure.
    
  . There may be a communication problem between the SVP and the CHA's 
    and DKA(F)'s due to changed internal IP addresses.
    
  . ALARM events associated with the CHA or DKC MicroProcessors or 
    Shared Memory may appear.
     
This problem occurs because the incorrect procedures are being used to
try to propagate or clone a configuration between two different SE9900
Subsystems.

The recommended fix is to ONLY use the SE9900 Offline SVP Configuration
Utility to propagate a fixed or sample configuration between two
Subsystems.  See the detailed procedure provided below.
Implementation: 
---
          |   |   MANDATORY (Fully Proactive)
           ---


           ---
          |   |   CONTROLLED PROACTIVE (per Sun Geo Plan)
           ---


           ---
          | X |   REACTIVE (As Required)
           ---
Corrective Action: 
The following recommendation is provided as a guideline for authorized
Sun Services Field Representatives who may encounter the above
mentioned problem.

It is recommended to ONLY use the SE9900 SVP Offline Configuration 
Utility to propagate a fixed or sample configuration to a new or 
alternate SE9900 unit.
   
The SE9900 Offline SVP Configuration Utility tool is available via 
the SE9900 Microcode CD. 

   e.g; D:\TOOLS\CONFIG\OFF_SVP

NOTE 1:	You must ONLY use the version of the SVP Configuration Tool that 
	is applicable to the Microcode version in use on the SE9900 
	subsystem on which you want to build a configuration. 

	Example: A SE9900 subsystem has Microcode version 01-18-09-00/00
	         installed; you must therefore only use the Offline SVP 
                 Configuration Utility from the 01-18-09-00/00 Microcode CD.

NOTE 2: You must NEVER install the SVP configuration utility tool on the 
        SVP PC. (The SVP should only ever be used for SVP related applications 
        and operations.)

To install the Configuration Utility tool (on a standard PC) from the 
OFF_SVP directory on the applicable version of the Microcode CD, please
adhere to the following procedure:

   . Run "setup.exe" (double click on the setup.exe windows icon).

Once the install is finished from the standard Windows Menu select:

   . Start->Programs->RAID400 Offline SVP

From this sub-menu, two utilities are available which are "DeskTop Define 
Install" and "Help"
Status: RO
X-Status: $$$$
X-UID: 0000000002

Selecting "Help" will provide the user some additional information on 
the correct usage of the SVP Offline Configuration tool.

NOTE 3: A valid configuration diskette (from the SE9900 subsystem that you 
        wish to build) will be required to be inserted in the PC's floppy 
        drive, prior to starting the SVP Offline tool.
Comments: 
None

============================================================================
Implementation Footnote: 
i)   In case of MANDATORY FINs, Sun Services will attempt to contact  
     all affected customers to recommend implementation of the FIN. 
   
ii)  For CONTROLLED PROACTIVE FINs, Sun Services mission critical    
     support teams will recommend implementation of the FIN (to their  
     respective accounts), at the convenience of the customer. 

iii) For REACTIVE FINs, Sun Services will implement the FIN as the   
     need arises.
----------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network 
browser as follows:
 
SunWeb Access:
-------------- 
* Access the top level URL of http://sdpsweb.ebay/FIN_FCO/

* From there, select the appropriate link to query or browse the FIN and
  FCO Homepage collections.
 
SunSolve Online Access:
-----------------------
* Access the SunSolve Online URL at http://sunsolve.Corp/

* From there, select the appropriate link to browse the FIN or FCO index.

Internet Access:
----------------
* Access the top level URL of https://infoserver.Sun.COM
--------------------------------------------------------------------------
General:
--------
* Send questions or comments to finfco-manager@Sun.COM
--------------------------------------------------------------------------
Statusactive