FIELD INFORMATION NOTICE
(For Authorized Distribution by SunService)
FIN #: I0955-1
Synopsis: Improved drive firmware will reduce the incidence of HDI failures on IBM Discovery disk drives.Create Date: Apr/18/03
SunAlert: No
Top FIN/FCO Report: No
Products Reference: IBM Drive Firmware
Product Category: Storage / Service
Product Affected:
Systems Affected:
-----------------
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
- A25 ALL Sun Enterprise 450 -
- A34 ALL Sun Enterprise 220R -
- A33 ALL Sun Enterprise 420R -
- E4500 ALL Sun Enterprise 4500 -
- E3500 ALL Sun Enterprise 3500 -
- E5500 ALL Sun Enterprise 5500 -
- E6500 ALL Sun Enterprise 6500 -
- E10000 ALL Sun Enterprise 10000 -
X-Options Affected:
-------------------
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
- T3 ALL Sun StorEdge T3 -
- T3+ ALL Sun StorEdge T3+ -
- A1000 ALL Sun StorEdge A1000 -
- D1000 ALL Sun StorEdge D1000 -
- D240 ALL Sun StorEdge D240 -
- A3500 ALL Sun StorEdge A3500 -
Parts Affected:
Part Number Description Model
----------- ----------- -----
540-4520-01 DRV ASSY 36GB 1 SCSI SPUD&PLAT -
540-4177-01 DRV ASSY 18GB10K 1 SCSI W/SPUD -
540-4440-01 DRV ASSY 18GB10K 1 FC LP W/SLED -
540-4367-01 DRV ASSY 36GB 1 FC LP W/SLED -
References:
ESC: 541752 - ics/ p/ 2hr/ 2 failed A3500 18GB hdds, pn 540-4178.
Issue Description:
IBM Discovery model disk drives installed in Sun systems may be
susceptible to early failure under certain circumstances due to Head
Disk Interference (HDI). This reliability issue can negatively impact
customer operations.
This issue only affects IBM Discovery 18Gb and 36Gb drives with the
following part numbers:
Sun P/N Vendor P/N
------- ----------
540-4520 IBM DDYS18350
540-4177 IBM DDYS36950
540-4440 IBM DDYFT18350
540-4367 IBM DDYFT36950
For all systems, to determine if a system has one of IBM Discovery drives,
do one of the following:
. If the system is down, run the "probe-scsi" command from the "ok"
prompt.
. If the system is up, run the "format" command.
. If Explorer has run, check the file /opt/SUNWexplorer/bin/diskinfo.
For A1000/A3x00 Arrays attached to a host, an alternative would be to
run one of the two following commands:
A. run #/usr/lib/osa/bin/drivutil -i
Ex: #/usr/lib/osa/bin/drivutil -i c1t0d0
B. From RM6 GUI,
RM6 GUI -> Configuration -> Module -> Profile -> drives
For T3/T3+ arrays, an alternative would be to use Explorer output or T3
commands to identify the part numbers. The "fru list" command can be used.
T3B Release 2.01.03 2002/11/14 20:16:35 (10.4.41.230)
Copyright (C) 1997-2001 Sun Microsystems, Inc.
All Rights Reserved.
qatest:/:<1>fru list
ID TYPE VENDOR MODEL REVISION SERIAL
------ ----------------- ----------- ----------- ------------- --------
u1ctr controller card 0301 501-5710-01( 0200/020103 101482
u2ctr controller card 0301 501-5710-02( 0200/020103 121902
u1d1 disk drive IBM DDYF36950SUN F65Y 23H00952
When this isue occurs, the following error code indicates that a drive
has failed due an HDI occurrence: "Sense Code 02x04".
When the drives are subjected to an excessive idle time (several
hours), the Head Air Bearing Surface (ABS) may pick up excessive disk
lubricant in the cavity of the ABS. This buildup of excessive
lubricant results in unstable flying characteristics with the ultimate
outcome of Head Disk Interference (HDI) and subsequent drive failures.
This issue is addressed by new disk drive firmware. The new drive
firmware monitors drive activity, and will exercise the drive head if
defined idle parameters are encountered. If idle times exceed the
algorithm metrics, the firmware will move the head at specific
intervals over the disk surface. Moving the head over the disk surface
provides an appropriate airflow which prevents lubricant accumulation
in the head ABS cavity.
There are two firmware patches, one for SCSI drives and one for T3 FCAL
drives.
SCSI Drives: patch 111534-04
Drive Models and Drive part numbers
540-4520 IBM DDYS18350
540-4177 IBM DDYS36950
T3 FCAL Drives: patch 114701-01
Drive Models and Drive part numbers
540-4440 IBM DDYFT18350
540-4367 IBM DDYFT36950
Implementation:
---
| | MANDATORY (Fully Proactive)
---
---
| | CONTROLLED PROACTIVE (per Sun Geo Plan)
---
---
| X | REACTIVE (As Required)
---
Corrective Action:
The following recommendation is provided as a guideline for authorized
Sun Services Field Representatives who may encounter the above
mentioned problem.
All IBM Discovery disk drives should be upgraded to the current version
of the drive firmware available from SunSolve:
. For T3/T3+ FCAL installtions: patch 114704-01 or later
. For all other installations: patch 111534-04 or later
Special firmware installation instructions are provided in the README
files.
Comments:
None.
============================================================================
Implementation Footnote:
i) In case of MANDATORY FINs, Sun Services will attempt to contact
all affected customers to recommend implementation of the FIN.
ii) For CONTROLLED PROACTIVE FINs, Sun Services mission critical
support teams will recommend implementation of the FIN (to their
respective accounts), at the convenience of the customer.
iii) For REACTIVE FINs, Sun Services will implement the FIN as the
need arises.
----------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network
browser as follows:
SunWeb Access:
--------------
* Access the top level URL of http://sdpsweb.central/FIN_FCO/
* From there, select the appropriate link to query or browse the FIN and
FCO Homepage collections.
SunSolve Online Access:
-----------------------
* Access the SunSolve Online URL at http://sunsolve.Central/
* From there, select the appropriate link to browse the FIN or FCO index.
Internet Access:
----------------
* Access the top level URL of https://spe.Sun.COM
--------------------------------------------------------------------------
General:
--------
* Send questions or comments to finfco-manager@Sun.COM
--------------------------------------------------------------------------