Document Audience: | INTERNAL |
Document ID: | I0986-1 |
Title: | Sun StorEdge T3+ FW 2.01.01 must upgrade to 2.01.03 FW or later and Sun StorEdge 3910/3960/6910/6960 SP Image Rev 2.1.2 must upgrade to Rev 2.3.1 or later. SunAlert: Yes |
Copyright Notice: | Copyright © 2005 Sun Microsystems, Inc. All Rights Reserved |
Update Date: | 2003-07-15 |
---------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------
FIELD INFORMATION NOTICE
(For Authorized Distribution by SunService)
FIN #: I0986-1
Synopsis: Sun StorEdge T3+ FW 2.01.01 must upgrade to 2.01.03 FW or later and Sun StorEdge 3910/3960/6910/6960 SP Image Rev 2.1.2 must upgrade to Rev 2.3.1 or later. SunAlert: YesCreate Date: Jun/27/03
SunAlert: Yes
Top FIN/FCO Report: Yes
Products Reference: Sun StorEdge T3+/3910/3960/6910/6960
Product Category: StorEdge / SW Admin
Product Affected:
Systems Affected:
-----------------
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
- ANYSYS - System Platform Independent -
X-Options Affected:
-------------------
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
- T3+ ALL Sun StorEdge T3+ Array -
- 3910 ALL Sun StorEdge 3910 Array -
- 3960 ALL Sun StorEdge 3960 Array -
- 6910 ALL Sun StorEdge 6910 Array -
- 6960 ALL Sun StorEdge 6960 Array -
Part Number Description Model
----------- ----------- -----
- - -
References:
PatchId: 112276-06 - T3+ 2.01.03: System Firmware Update.
112276-07 - T3+ 2.01.04: System Firmware Update.
Manual: 816-5253-11: Sun StorEdge(tm) 3900 and 6900 Series Reference
and Service Manuals
FIN: I0876-3 - Patch 112276-06 (Firmware 2.01.03) and later for
Sun StorEdge T3+ (T3B) Arrays resolves several
disk error handling issues.
Sun Alert: 52562
Issue Description:
Sun StorEdge T3+ Arrays with firmware version 2.01.01 and Sun StorEdge
3900/6900 Series systems with Service Processor (SP) Image 2.1.2 are
susceptible to loss of volume access or data loss due to a disk error
handling issue.
Affected units may be identified as follows:
Note that T3 (T3A) arrays are not affected by this issue.
T3+ (T3B)
---------
Affected arrays will have firmware version 2.01.01 installed.
To verify the current firmware version running on a target T3+ system,
use the 'ver' command at the T3+ command line as follows:
t3:/:<3>ver
T3B Release 2.00 2001/07/12 19:35:12 (10.4.32.63)
Copyright (C) 1997-2001 Sun Microsystems, Inc.
All Rights Reserved.
3900/6900 Series
----------------
Login to the SP and type: "cat /etc/motd". The response on the SP
should indicate that the revision of the Service Processor image
is 2.1.2. Only SP image revision 2.1.2 contains T3+ firmware 2.01.01
and must be upgraded.
Depending upon the
1) configuration,
2) application,
3) type of volume manager,
in use, the host may
1) continue the retry read/write operations,
2) unmount the volume,
3) cause the application to timeout.
If a disk drive experiences one of the following errors,
"Sense Key = 0x4",
"Sense Key = 0x01, Asc = 0x5d"
the T3+ will repeatedly retry read/write operations. This may appear to
the host as if the T3+ is not responding.
If more than one disk in a given RAID volume reports these particular
errors, then ALL of the drives that report these errors WILL be disabled.
This will result in the volume being unmounted and will cause a loss of
access to data.
T3+ FW 2.01.03 and above has been enhanced to properly disable and
handle occurrences of the 0x4 and 0x01/0x5d SCSI errors.
This issue is addressed with T3+ firmware patch 112276-06 (or later).
This firmware is available for the 3900/6900 Series in SP Image 2.3.1
(or later). To avoid the potential loss of access to data, special
pre-installation and post-installation procedures are required with
patch 112276-06 and are detailed in FIN I0876-3.
Implementation:
---
| | MANDATORY (Fully Proactive)
---
---
| X | CONTROLLED PROACTIVE (per Sun Geo Plan)
---
---
| | REACTIVE (As Required)
---
Corrective Action:
The following recommendation is provided as a guideline for authorized
Sun Services Field Representatives who may encounter the above
mentioned issue.
For T3+ (T3B)
-------------
Install firmware patch 112276-06 or later. FIN I0876-3 provides details
for this procedure and must be completely followed for the Corrective
Action.
For 3900/6900 Series
--------------------
Identify whether your customer is running SP image rev 2.1.2. Login to
the SP (Service Processor) and type: "cat /etc/motd". The response on
the SP should indicate that the revision of the Service Processor image
is 2.1.2. Only SP image 2.1.2 contains T3+ firmware 2.01.01 and must be
upgraded.
Upgrade the Service Processor Image to rev 2.3.1 or later by accessing
the image and following the README file for upgrade information at:
http://futureworld.central/WSTL/PROJECTS/SPImage/web/Downloads.shtml
Once the Service Processor upgrade is completed, the T3+ controller
firmware must be upgraded as a separate process. It is very important to
follow FIN I0876-3 before installing the T3+ firmware upgrade patch on
3900/6900 Series systems. The T3+ upgrade process is explained in the
patch document and in the image README file. It is also explained in the
Sun StorEdge(tm) 3900 and 6900 Series Reference and Service Manuals,
816-5253-11.
Comments:
None
============================================================================
Implementation Footnote:
i) In case of MANDATORY FINs, Sun Services will attempt to contact
all affected customers to recommend implementation of the FIN.
ii) For CONTROLLED PROACTIVE FINs, Sun Services mission critical
support teams will recommend implementation of the FIN (to their
respective accounts), at the convenience of the customer.
iii) For REACTIVE FINs, Sun Services will implement the FIN as the
need arises.
----------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network
browser as follows:
SunWeb Access:
--------------
* Access the top level URL of http://sdpsweb.central/FIN_FCO/
* From there, select the appropriate link to query or browse the FIN and
FCO Homepage collections.
SunSolve Online Access:
-----------------------
* Access the SunSolve Online URL at http://sunsolve.central/
* From there, select the appropriate link to browse the FIN or FCO index.
Internet Access:
----------------
* Access the top level URL of https://spe.sun.com
--------------------------------------------------------------------------
General:
--------
* Send questions or comments to finfco-manager@Sun.COM
--------------------------------------------------------------------------