Document Audience: | INTERNAL |
Document ID: | I1018-1 |
Title: | Best Practices Guide for diagnosing UltraSPARC III memory errors now available. |
Copyright Notice: | Copyright © 2005 Sun Microsystems, Inc. All Rights Reserved |
Update Date: | 2004-11-30 |
------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
------------------------------------------------------------------------
FIELD INFORMATION NOTICE
(For Authorized Distribution by SunService)
FIN #: I1018-1
Synopsis: Best Practices Guide for diagnosing UltraSPARC III memory errors now available.Create Date: Dec/10/03
SunAlert: No
Top FIN/FCO Report: No
Products Reference: UltraSPARC III Best Practices Guide
Product Category: Server / Documentation
Product Affected:
Systems Affected:
-----------------
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
- S8 ALL Sun Fire 3800 -
- S12 ALL Sun Fire 4800 -
- S12i ALL Sun Fire 4810 -
- S24 ALL Sun Fire 6800 -
- F12K ALL Sun Fire 12000 -
- F15K ALL Sun Fire 15000 -
- A28 ALL Sun Blade 1000 -
- A35 ALL Sun Fire 280R -
- A37 ALL Sun Fire V480 -
- A30 ALL Sun Fire V880 -
- N28 ALL Netra 20 -
- A40 ALL Sun Fire V1280 -
X-Options Affected:
-------------------
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
- - - - -
Parts Affected:
----------------------
Part Number Description Model
----------- ----------- -----
- - -
References:
FIN: I0377-1: ECC Memory Error Guideline for Enterprise servers.
I0760-2: Too many Memory DIMMs are being unnecessarily replaced on the
UltraSPARC II, III, III+, IIIi and, IV families of systems,
increasing customers' service actions and related system downtime.
I0805-1: DIMMs are being unnecessarily replaced on Enterprise 10000
servers.
I0954-1: Diagnosing Main Memory errors versus L2SRAM errors on Sun
Fire 3800/4800/4810/6800, Sun Fire 12K/15K and Sun Fire
V1280 systems.
SRDB: 48026
21773
45120
Info Doc: 49085
URL: http://sdpsweb.central/FIN_FCO/FIN/FINI1018-1_dir/BestPracticesGuide.pdf
https://spe.sun.com/info/control/DocumentSelectByType/doc=542/Fins_doc.pdf
Issue Description:
------------------------------------------------------------------------
| Change of History: |
| ================== |
| Updated Date: Dec/10/03 |
| |
| Updated Sections: Reference, Problem Description, Corrective Action |
| |
| . Created Best Practices Guide document URL for an authorized |
| Sun service partners and added them in the Reference, Problem |
| Description, and the Corrective Action section. |
| |
------------------------------------------------------------------------
Memory errors and memory hardware replacement constitutes a significant
portion of downtime and dissatisfiers for Sun customers. In addition,
roughly 80% of the DIMMs returned to our memory vendors are diagnosed
as "no trouble found" (NTF), indicating good components are being
replaced. Therefore, understanding the causes of memory errors and
proper diagnosis of the faults is key to maintaining optimum system
reliability and uptime.
A "Best Practices Guide for Memory Errors in UltraSPARC III Products"
has been produced as the result of a Sun Sigma project. This best
practices guide describes the different memory error events and then
steps the reader through the process of identifying the component that
triggered the event.
This document can be found at:
http://sdpsweb.central/FIN_FCO/FIN/FINI1018-1_dir/BestPracticesGuide.pdf
However, this document may not be accessible by an authorized Sun service
partners. Therefore, Sun service partners should use the following URL for
the same document.
https://spe.sun.com/info/control/DocumentSelectByType/doc=542/Fins_doc.pdf
Implementation:
---
| | MANDATORY (Fully Proactive)
---
---
| | CONTROLLED PROACTIVE (per Sun Geo Plan)
---
---
| X | REACTIVE (As Required)
---
Corrective Action:
The following recommendation is provided as a guideline for authorized
Sun Services Field Representatives who may encounter the above
mentioned issue.
Utilize the "Best Practices Guide for Memory Errors in UltraSPARC III
Products" as an aid in diagnosing memory issues on UltraSPARC III
platforms. The guide is located at:
http://sdpsweb.central/FIN_FCO/FIN/FINI1018-1_dir/BestPracticesGuide.pdf
Note: This document may NOT be distributed to an authorized Sun service partners.
Sun service partners can get the same document from the following website.
https://spe.sun.com/info/control/DocumentSelectByType/doc=542/Fins_doc.pdf
Comments:
None.
============================================================================
Implementation Footnote:
i) In case of MANDATORY FINs, Sun Services will attempt to contact
all affected customers to recommend implementation of the FIN.
ii) For CONTROLLED PROACTIVE FINs, Sun Services mission critical
support teams will recommend implementation of the FIN (to their
respective accounts), at the convenience of the customer.
iii) For REACTIVE FINs, Sun Services will implement the FIN as the
need arises.
----------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network
browser as follows:
SunWeb Access:
--------------
* Access the top level URL of http://sdpsweb.central/FIN_FCO/
* From there, select the appropriate link to query or browse the FIN and
FCO Homepage collections.
SunSolve Online Access:
-----------------------
* Access the SunSolve Online URL at http://sunsolve.central/
* From there, select the appropriate link to browse the FIN or FCO index.
Internet Access:
----------------
* Access the top level URL of https://spe.sun.com
--------------------------------------------------------------------------
General:
--------
* Send questions or comments to finfco-manager@Sun.COM
--------------------------------------------------------------------------