Document Audience: | INTERNAL |
Document ID: | I1117-1 |
Title: | Identifying an older system that requires an X-Option FAN Upgrade Kit (X7418A) when adding 1GB memory DIMMs on Sun Fire V210 systems. |
Copyright Notice: | Copyright © 2005 Sun Microsystems, Inc. All Rights Reserved |
Update Date: | 2004-11-23 |
------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
------------------------------------------------------------------------
FIELD INFORMATION NOTICE
(For Authorized Distribution by Sun Services)
FIN #: I1117-1
Synopsis: Identifying an older system that requires an X-Option FAN Upgrade Kit (X7418A) when adding 1GB memory DIMMs on Sun Fire V210 systems.Create Date: Jul/16/04
SunAlert: No
Top FIN/FCO Report: No
Products Reference: Sun Fire V210 Servers
Product Category: Server / Diag/Doc/Service
Product Affected:
Systems Affected:
-----------------
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
- N31 ALL Sun Fire V210 Server -
X-options Affected:
--------- --------
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
X7418A - - Sun Fire V210 Fan Kit -
N31-XUB1-9S-512AV1 - - SF V210 1x1.06GHz 512MB 1X36G -
N31-XUB2-9S-204AV2 - - SF V210 2x1.06GHz 2GB 2X36GB -
Parts Affected:
----------------------
Part Number Description Model
----------- ----------- -----
602-2307-02 or lower SF V210 1X1.002GHZ 512MB 1X36GB -
602-2394-02 or lower SF V210 2X1.002GHZ 2GB 2X36GB -
References:
ECO: WO_28377
Manual: 817-4492-10 Sun Fire V210 Server Fan Module Installation Guide.
Issue Description:
This FIN details how to identify Sun Fire V210 systems that have the
old fans and require installation of the FAN Upgrade X-option when
installing 1GB memory DIMMs.
The Sun Fire V210 can now support 1GB memory DIMMs however more
powerful system fans are required. All new builds of Sun Fire V210
systems contain the upgraded fans were available since February, 2004.
When a customer wishes to install 1GB memory DIMMs into older Sun Fire
V210 system, an X-option Fan Upgrade Kit Part Number x7418A MUST also
be purchased by the customer via the normal sales process.
The following methods have also been adopted to help identify when the
X-option Fan Upgrade Kit is required.
A. Stickers are being fitted to the systems to identify that new
fans are fitted.
B. The Webdesk system configurator currently warns of the need for a
Fan Upgrade Kit when 1GB DIMMs are selected.
C. The long description of the 1GB Memory DIMM X-option is also being
modified to indicate which versions of the Sun Fire V210 require the
Fan Upgrade Kit
Sun Fire V210 Systems that require the X-option Fan Upgrade Kit to be
fitted can be identified by the Manufacturing Part number located on
the right hand side of the System. See the CORRECTIVE ACTION section of
this FIN for details of which systems require the X-option Fan Upgrade
Kit.
New uprated fans were introduced into the Sun Fire V210 system to
enable the product to support 1GB memory DIMMs. An X-option Fan Upgrade
Kit is available for Customers to purchase that enables installation
of 1GB memory DIMMs in older systems which do not have the uprated
fans.
Implementation:
---
| | MANDATORY (Fully Proactive)
---
---
| | CONTROLLED PROACTIVE (per Sun Geo Plan)
---
---
| X | REACTIVE (As Required)
---
Corrective Action:
The following recommendation is provided as a guideline for authorized
Sun Services Field Representatives who may encounter the above
mentioned issue.
To identify whether the FAN upgrade Kit X-option is required, check the
Manufacturing Part Number of the system which can be found on the right
hand side label (when viewed from the front) of the Sun Fire V210 system.
The list below indicates the systems that require, or, do not require
Fan Upgrade Kit.
Require Fan Upgrade Kit:
602-2307-01
602-2307-02
602-2394-01
602-2394-02
Do Not Require Fan Upgrade Kit:
602-2307-04
602-2394-04
602-2692-01 (new 73GB config)
602-2693-01 (new 73GB config)
Comments:
None.
============================================================================
Implementation Footnote:
i) In case of MANDATORY FINs, Sun Services will attempt to
contact all affected customers to recommend implementation of
the FIN.
ii) For CONTROLLED PROACTIVE FINs, Sun Services mission critical
support teams will recommend implementation of the FIN (to their
respective accounts), at the convenience of the customer.
iii) For REACTIVE FINs, Sun Services will implement the FIN as the
need arises.
----------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network
browser as follows:
SunSolve Internal Access:
_______________________
* Access the SunSolve Online URL at http://sunsolve.Central/
* From there, select the appropriate link to browse the FIN or FCO index.
Internet Access:
_______________
* Access the top level URL of https://spe.sun.com
FIN/FCO Homepage Access:
_________________________
* Access the top level URL of http://sdpsweb.Central/FIN_FCO/index.html
* From there, select the appropriate link to query or browse the FIN and
FCO Homepage collections.
To submit either a FIN or FCO refer to the following URLs for templates
and instructions;
* For FCO: http://pronto.central/fco.html
* For FIN: http://pronto.central/fin.html
--------------------------------------------------------------------------
General:
--------
* Send questions or comments to finfco-manager@Sun.COM
--------------------------------------------------------------------------