Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

3Y Power
420 Watt Power Supply

Disk Arrays: StorEdge 3310, 3320, 3510, 3511

Options XTA-3310-DC-KIT / XTA-3000-2UDC-KIT

370-5527 370-6798 371-0109
DC Input Power Supply
Unknown Model
3310/3510
XTA-3310-DC-KIT
DC Input Power Supply
Unknown Model
3310/3510/3511
XTA-3000-2UDC-KIT
DC Input Power Supply
Unknown Model
3310/3320/3510/3511
XTA-3000-2UDC-KIT

DC Input

-36 to -72V *
* As described in Installation Manual 816-7290-10

DC Output

+5V +12V
35A 25A

Notes

  1. Power supply hot swap operation during data transfer requires 370-5527-03 (or higher) or 370-6798. Refer to ECO WO_26372 of April 2003 and FCO A0211-1 of June 2003.
  2. Standard configurations of the StorEdge 3310 are available with DC Input Power.
  3. Standard configurations of the StorEdge 3510 are available with DC Input Power.
  4. Standard configurations of the StorEdge 3511 are not available with DC Input Power.
  5. The difference between 370-5527 and 370-6798 is the regulatory agency labeling.
  6. The electrical warning label on 370-5527 is not visible if the power supply is installed in the left side of the StorEdge 3511. Do not use 370-5527 in the StorEdge 3511.

  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback