Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Astec AA23650
400 Watt Power Supply

Servers: Sun Fire V240 (1.002GHz/1.280GHz/1.336GHz/1.503GHz)
Telco: Netra 240, 440

Options X7428A / X7428A-4

300-1674 300-1846
Type A192
AC Input Power Supply
Option X7428A
N440/V240
Type A192
AC Input Power Supply
Option X7428A-4
N240/N440/V240
L

AC Input

90-264Vac 47-63Hz Less than 6.5 Amps RMS at 100Vac

DC Output

+3.3V +5V +12V -12V +5VSB
20.3A 17.2A 25.0A 0.42A 2.8A
Maximum combined output of +3.3, +5, and +12 is 381 Watts

Sun Fire V240 Codename: Enchilada 2U
Netra 240 Codename: Enchilada 19
Netra 440 AC Codename: Chalupa 19 AC

Option Notes

  1. Option X7428A replaced Option X7407A.
  2. The Last Order Date for Option X7407A was 05/06/05.
  3. The Last Order Date for Option X7428A was 04/14/06.
  4. Option X7428A was Power Supply 300-1674.
  5. Option 7428A was Netra 240 1.28GHz System Board 375-3120 or 375-3247.
  6. Options 7428A-4 and X7428A-4 are Power Supply 300-1846.

Non-RoHS-Compliant System Notes

  1. The 300-1674 was used in the Netra 440.
  2. The 300-1674 was used in the 1.336GHz/1.503GHz Sun Fire V240.
  3. The 300-1674 was added to 1.002/1.280GHz V240's in March 2005. (WO_30832)
  4. The 300-1674 was added to 1.002/1.280GHz V240's in May 2005. (WO_31220)
  5. Netra 240 1.503GHz systems shipped with 300-1674.
  6. Netra 240 1.280GHz systems shipped with 300-1568 until 30 March 2005.
  7. Netra 240 1.280GHz systems changed from 300-1568 to 300-1674 in March 2005. (WO_30337)

  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback