Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

FDK PEX705-40
Danish 184 Watt Power Supply

Servers: Enterprise 3x00V5

300-1317
Type A115
AC Input Power Supply

AC Input
VOLTAGE CURRENT FREQUENCY
100 - 240V 12A 47 - 63HZ

DC Output
+5V +5V +12V +12V MAXIMUM
CONTINUOUS
15A 0A 8.5A 1.5A 195 Watts

E3000V5 Notes

  1. One 300-1317 Power Supply is supported per system.
  2. Use 300-1301 as the redundant Peripheral Power Supply.
  3. Use Filler Panel 540-2593 when 300-1301 is not installed.

E3500V5 Notes

  1. One 300-1317 Power Supply is supported per system.
  2. Use 300-1358 as the redundant Peripheral Power Supply.
  3. Use Filler Panel 540-3815 when 300-1358 is not installed.

Notes

  1. Use AC power cord 530-2301, Option X389L.
  2. Power cord 530-2301 requires a 16A IEC309 receptacle.
  3. Fan Tray 540-2757 or 300 Watt Power/Cooling Module 300-1260 provides cooling for the 184 Watt Power Supply.
  4. The 184 Watt Power Supply provides the following functions:
    AC Input power
    +5Vdc and +12Vdc peripheral tray power
    +5Vdc and +12Vdc drive precharge (non redundant)
    +3.3Vdc and +5Vdc system precharge (non redundant)
    +5Vdc redundant system power
    +12Vdc redundant power for PCM fans
    +12Vdc redundant power for E3000 Auxiliary Fan Module
    +5Vdc auxilliary power for Clock Board remote console serial port

  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback