| FDK PEX821-301900 Watt Power Supply
 
| Servers: | Sun Fire 6800, E6900 |  
 
| 300-1595 | 300-1930 | 300-2225 |  X6800-USIV-KIT / X6800-USIV-KIT-Z
| Type A184 AC Input Power Supply
 Specification 950-4229
 X6800-USIV-KIT
 | Type A184 AC Input Power Supply
 Specification 950-4229
 X6800-USIV-KIT-Z
 L
 | Type A184 AC Input Power Supply
 Specification 950-4229
 X6800-USIV-KIT-Z
 L
 |  
 
| Front View 
  |  | Rear View 
  |  AC Input 
| 200/220-240V   12A/10A   47-63Hz |  DC Output 
| 1 | 56.2V | 32.5A |  
| 2 | 55.0V | 1.45A |  
 
| Sun Fire 6800 Codename: Serengeti 24 Sun Fire E6900 Codename: Amazon 6
 |  Notes
Sun Fire 6800 shipped with 300-1459.
Sun Fire E6900 ships with 300-1595, 300-1930, 300-1836, or 300-2223.
Sun Fire 6800 requires 300-1595, 300-1930, 300-1836, 300-2223, or 300-2225
    with UltraSPARC IV.Sun Fire 6800 requires 300-1595, 300-1930, 300-1836, 300-2223, or 300-2225
    with 1.8GHz UltraSPARC IV+.
 Sun Fire 6800 and E6900 require 300-1836 or 300-2223 with
    1.95GHz UltraSPARC IV+.
Six 300-1595 power supplies are in upgrade kit X6800-USIV-KIT.Six 300-2225 power supplies are in upgrade kit X6800-USIV-KIT-Z.
 
Mixing power supply types is not supported except during an upgrade.
The 300-1930 was replaced by 300-2225 because of DecaBDE in the
    ejector handle resin.
The European Unions October 12, 2005 exemption 2005/717/EC for use of
    DecaBDE from Directive 2002/95/EC ended July 1, 2008.
The 300-2225 is not used in new system builds of the E6900 (as of 08/11/08).
The 300-2225 replaced 300-1930 in X6800-USIV-KIT-Z in August 2008.