Switching Power Inc Sun-450 350 Watt Power Supply
Telco: |
Netra t 1100, 1120 |
300-1355 |
DC Input Power Supply AMP connectors Used Before 5/99 |
J1 to System Board J2901
PIN |
FUNCTION |
|
PIN |
FUNCTION |
1 |
+3.3 -Sense |
9 |
Off |
2 |
+3.3 +Sense |
10 |
On |
3 |
+5.0 -Sense |
11 |
-12V |
4 |
+5.0 -Sense |
12 |
POR |
5 |
+3.0 -Sense |
13 |
+12V Return |
6 |
+3.0 +Sense |
14 |
+12V |
7 |
+3.0 OVP Program |
15 |
+12 Return |
8 |
+3 +V Program |
16 |
+12 |
J3 to System Board J2902
PIN |
COLOR |
FUNCTION |
1 |
Black |
+5.0 Return |
2 |
Red |
+5.0 |
3 |
Black |
+3.0 |
4 |
Blue |
+3.0 Return |
J2 to System Board J2903
PIN |
COLOR |
FUNCTION |
1 2 3 |
Black |
+3.3 Return |
4 5 6 |
Yellow |
+3.3 |
DC Input
DC Output
V1 |
V2 |
V3 |
V4 |
V5 |
+3.3V |
+5.0V |
+12.0V |
-12.0V |
-2.5V |
50.0A |
35.0A |
6.0A |
1.0A |
28.0A |
Notes
- Three System Board memory banks can be installed with power supply
<=300-1355-03.
- Four System Board memory banks can be installed with power supply
>=300-1355-04.
- AMP connectors require two #14AWG wires to the circuit breaker.
Artesyn EP071332 350 Watt Power Supply
Netra t 1120
300-1405 |
300-1462 |
Type D119 DC Input Power Supply
AMP connectors Used From 5/99 to 11/99 |
Type D119 DC Input Power Supply
Wago connectors Used After 11/99 |
J1 to System Board J2901
PIN |
FUNCTION |
|
PIN |
FUNCTION |
1 |
+3.3 -Sense |
9 |
Off |
2 |
+3.3 +Sense |
10 |
On |
3 |
+5.0 -Sense |
11 |
-12V |
4 |
+5.0 -Sense |
12 |
POR |
5 |
+3.0 -Sense |
13 |
+12V Return |
6 |
+3.0 +Sense |
14 |
+12V |
7 |
+3.0 OVP Program |
15 |
+12 Return |
8 |
+3 +V Program |
16 |
+12 |
J3 to System Board J2902
PIN |
COLOR |
FUNCTION |
1 |
Black |
+5.0 Return |
2 |
Red |
+5.0 |
3 |
Black |
+3.0 |
4 |
Blue |
+3.0 Return |
J2 to System Board J2903
PIN |
COLOR |
FUNCTION |
1 2 3 |
Black |
+3.3 Return |
4 5 6 |
Yellow |
+3.3 |
DC Input
DC Output
V1 |
V2 |
V3 |
V4 |
V5 |
+3.3V |
+5.0V |
+12.0V |
-12.0V |
-2.5V |
50.0A |
35.0A |
6.0A |
1.0A |
28.0A |
Netra t 1120 Codename: Lightweight 2 |
Notes
- Four System Board memory banks can be installed with
300-1405 and 300-1462.
- The 300-1405 and 300-1462 are not qualified for use in the Netra t 1100.
- AMP connectors require two #14AWG wires to the circuit breaker.
- Wago connectors require three #12AWG wires to the circuit breaker.
|