Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | ||
|
|||
Tyco A214
| ||||||||||||||||||||||||||||||||||||||||
| 300-1848 | 300-1852 | 300-2306 |
|---|---|---|
|
Astec DS550 AC Input Power Supply V445 X4100/X4100 M2 X4200/X4200 M2 December 2006 8052A-Z L |
Tyco A214 AC Input Power Supply V215/V245/V445 Netra T2000 June 2006 8428A-Z L |
Emerson DS550 Type A214S AC Input Power Supply Netra X4200 M2 UL 60950-1 2nd Edition EN 60950-1 2nd Edition November 2010 |
| 100-240V | 47-63Hz | 8A Max |
| +12V | +3.3Vsb |
|---|---|
| 45.0A | 3.1A |
Efficiency of 300-1848, 300-1852 and 300-2306
| 110V | 75 - 100% Load | >=87% |
| 110V | 30 - 50% Load | >=83% |
| 220V | 100% Load | >=88% |
| 220V | 75% Load | >=87% |
| 220V | 30 - 50% Load | >=84% |
Efficiency of 300-1757 and 300-1945
| 110V | 50 - 100% Load | >=82% |
| 110V | 30 - 50% Load | >=78% |
| 220V | 50 - 100% Load | >=84% |
| 220V | 30 - 50% Load | >=80% |
|
Copyright © 2011 Sun Microsystems, Inc. All rights reserved. Feedback | |||