DC Power Distribution Board

Servers: Sun Fire V240
Telco: Netra 240

371-0821 371-3028
unknown vendor part
V240/N240
L
unknown vendor part
N240 only
L

Sun Fire V240 Codename: Enchilada 2U
Netra 240 Codename: Enchilada 19

Notes

  1. The wire harness does not have a Sun part number.
  2. The 4-Pin, 10-Pin, and 24-Pin wire harnesses are soldered and bundled with tie wraps.
  3. The 4-Pin harnesses require a 13 mm grommet in the Sun Fire V240 chassis.
  4. The grommet does not have a Sun part number.
  5. The 371-0821 was added as a manufacturing substitute for 370-5138 in the pre-RoHS Sun Fire V240 in January 2006. (WO_32387)
  6. The 371-0821 was replaced by 371-3028 in the Netra 240 in June 2007. (WO_36859)
  7. The 371-3028 includes shorter cables than 371-0821, and cannot be used in the Sun Fire V240.

Netra 240 Front Blower Notes

  1. Blower 371-0823-01 has two 3-Pin connectors for I2C.
  2. Blower 371-0823-01 has one 4-Pin connector for Power.
  3. Netra 240 Service Manual 817-2699-13 does not include removal and replacement
    procedures for Blower 370-6124-02 or 371-0823-01.