SBus Prestoserve
Workstations: |
Sun 4/15, 4/30, 4/50, 4/75
SPARCstation 4, 5, 10, 20
Ultra 1, 1E, 2 |
Servers: |
SPARCserver 6x0MP |
Option 1021
Switch SW1
SETTING |
DESCRIPTION |
BAT |
Enables battery backup mode |
5V |
Disables battery backup mode |
Switch SW2
Press SW2 to determine the cache data state.
LED On |
Cache data in memory |
LED Off |
No cache data in memory |
Power:
- 0.8 Amps @ +5Vdc
- 4.0 Watts
Software Compatibility
OPERATING SYSTEM |
SBus PRESTOSERVE |
SunOS 4.1.1 |
2.3 |
SunOS 4.1.2 |
2.3 |
SunOS 4.1.3 |
2.3 |
Solaris 2.1 |
2.4 / 2.4.1 / 2.4.2 |
Solaris 2.2 |
2.4 / 2.4.1 / 2.4.2 |
Solaris 2.3 |
2.4 / 2.4.1 / 2.4.2 |
Solaris 2.4 |
2.4 / 2.4.1 / 2.4.2 |
Solaris 2.5 |
2.4.2 |
Solaris 2.5.1 |
2.4.2 |
Solaris 2.6 |
2.4.2 |
Solaris 7 |
2.4.2 |
Notes
- Set SW1 to BAT when the board is installed. Software will not
initialize Prestoserve unless battery backup is enabled.
- Set SW1 to +5V when the board is removed and cache data does not need
saving.
- Cache is cleared when SW1 is set to +5V for more than five minutes.
- Do NOT accelerate the root file system.
- Install Patch 101714-01 for Prestoserve 2.4 and 2.4.1, or 103043-08 for Prestoserve 2.4.2.
- The Prestoserve hardware design is not compatible with 64-bit DVMA.
Disable 64-bit DVMA when Prestoserve is used with Ultra 1 Model 170E,
Ultra 2, and SunSwift. Refer to BugID 1224649. Add the following to
/etc/system:
- set fas:fas_enable_sbus64 = 0
- Only 32-bit drivers are provided by the Prestoserve software, so if
you are running Solaris 7, you must boot in 32-bit mode for the
Prestoserve drivers to load.
References
-
SBus Prestoserve User's Manual, 800-6396
-
Prestoserve User's Guide, 801-4896.
|