Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback



Sun Fire V210 / V240 / V250 / V440
Sun Blade 1500 (Red) / Sun Blade 2500 (Red)
Sun Blade SX1500 / SX2500
Sun Fire B200x
Netra 240 / 440

Options 7402 / 7403 / 7404

370-5565 370-4939 370-4940
DDR, PC2100, CL2, ECC
Serial Presence Detect 0.0
256MB Registered DIMM
512MB Option 7402
512MB FRU F370-5565

Not supported on:
Sun Fire V440
Netra 440
SB2500
DDR, PC2100, CL2, ECC
Serial Presence Detect 0.0
512MB Registered DIMM
1GB Option 7403
1GB FRU F370-4939
DDR, PC2100, CL2, ECC
Serial Presence Detect 0.0
1GB Registered DIMM
2GB Option 7404
2GB FRU F370-4940

See 1GB DIMM Note below
Not shipped in Sun Blade 1500 (Silver) or Sun Blade 2500 (Silver)

Notes

  1. Bank, Rank, DIMM, and XOR Interleaving is supported.
  2. Memory Options 7402, 7403, and 7404 include two DIMMs from the same vendor.
  3. FRUs F370-5565, F370-4939, and F370-4940 include two DIMMs from the same vendor.
  4. Only CPU 0 DIMMs are accessible in a single CPU system (CPU 0).
  5. Memory is mapped globally and is accessible by any CPU in a multi-CPU system.
  6. Do Not mix DIMMs speeds, manufacturers, or part numbers in the same bank.
  7. Mixed speed or mixed SPD DIMMs on the same board is supported in OBP.
  8. Mixed speed or mixed SPD DIMMs in the same bank is not supported in OBP.
  9. Mixed speed DIMMs in different banks serving the same CPU run at the lower speed.

Installation Notes

  1. The minimum requirement is two DIMMs.
  2. Install the first SB1500 DIMMs in DIMM0 and DIMM1 or DIMM2 and DIMM3.
  3. Install the first SB2500 DIMMs in CPU0 DIMM2 and DIMM3.
  4. Install the first V210 DIMMs in CPU0 B0/D0 and B0/D1 or B1/D0 and B1/D1.
  5. Install the first V240 DIMMs in CPU0 B0/D0 and B0/D1 or B1/D0 and B1/D1.
  6. Install the first V250 DIMMs in CPU0 DIMM0 and DIMM1.
  7. Install the first V440 DIMMs in CPU0 B0/D0 and B0/D1 or B1/D0 and B1/D1.
  8. Install the first Netra 240 DIMMs in CPU0 B0/D0 and B0/D1.
  9. Install the first Netra 440 DIMMs in CPU0 B0/D0 and B0/D1 or B1/D0 and B1/D1.
  10. Install the first Sun Fire B200x DIMMs in 2A and 2B.

1GB DIMM Note

  1. Sun Fire V210 systems with the following manufacturing part numbers require Fan Upgrade Kit X7418A when upgrading to 1GB DIMMs:
    602-2307-01
    602-2307-02
    602-2394-01
    602-2394-02
  2. The manufacturing part number can be found on a sticker on the right rear side of the system (as seen from the front).

UltraSPARC IIIi Notes

  1. The Memory Control Unit is integrated in the UltraSPARC IIIi.
  2. UltraSPARC IIIi supports 128MB to 1GB single bank DIMMs.
  3. UltraSPARC IIIi supports 256MB to 2GB dual bank DIMMs.
  4. Two DIMMs of the same bank size (single or dual) and memory size form a bank.
  5. Memory error reporting identifies a failing Bank, not a single failing DIMM.
  6. If a memory bank is mixed with single bank and dual bank DIMMs, the memory bank will fail POST. Always replace DIMMs as a pair in the same bank. Do not move single DIMMs between banks unless all DIMMs are identified as the same.

References

  1. Sun Fire V210 and V240 Administration Guide, 816-4826.
  2. Sun Fire V210 and V240 Parts Replacement Manual, 817-0743.
  3. Netra 240 Server Installation Guide, 817-2698.
  4. Netra 240 Server Service Manual, 817-2699.
  5. Netra 440 Server Installation Guide, 817-3882.
  6. Netra 440 Server Service Manual, 817-3883.
  7. Sun Blade 2500 Service, Diagnostics, and Troubleshooting Manual, 816-0996.
  8. Sun Blade 1500 Service, Diagnostics, and Troubleshooting Manual, 816-7564.
  9. Sun Fire V440 Server Installation Guide, 816-7727.
  10. Sun Fire V440 Server Administration Guide, 816-7728.
  11. Sun Fire V440 Server Parts Installation and Removal Guide, 816-7729.
  12. Sun Fire V440 Server Product Notes, 816-7733.
  13. Sun Fire V250 Server Installation Guide, 817-0899.
  14. Sun Fire V250 Server Administration Guide, 817-0900.
  15. Sun Fire V250 Server Parts Replacement Manual, 817-0901.



Sun Fire V210 / V240 / V250 / V440
Sun Blade 1500 (Red & Silver)
Sun Blade 2500 (Red & Silver)
Sun Blade SX1500 / SX2500
Netra 240 / 440

Options 7602 / 7603 / 7604

370-6201 370-6202 370-6203
DDR266, PC2100, CL2, ECC
Serial Presence Detect 1.0
256MB Registered DIMM
512MB Option 7602
512MB FRU 540-6228

Only supported on:
V210/V240/V250
SB1500 (Red)
Netra 240
DDR266, PC2100, CL2, ECC
Serial Presence Detect 1.0
512MB Registered DIMM
1GB Option 7603
1GB FRU 540-6229
DDR266, PC2100, CL2, ECC
Serial Presence Detect 1.0
1GB Registered DIMM
2GB Option 7604
2GB FRU 540-6230

See 1GB DIMM Note below

Notes

  1. Bank, Rank, DIMM, and XOR Interleaving is supported.
  2. Memory Options 7602, 7603, and 7604 include two DIMMs from the same vendor.
  3. FRUs F540-6228, F540-6229, and F540-6230 include two DIMMs from the same vendor.
  4. Only CPU 0 DIMMs are accessible in a single CPU system (CPU 0).
  5. Memory is mapped globally and is accessible by any CPU in a multi-CPU system.
  6. Do Not mix DIMM speeds, manufacturers, or part numbers in the same bank.
  7. Mixed speed or mixed SPD DIMMs on the same board is supported in OBP.
  8. Mixed speed or mixed SPD DIMMs in the same bank is not supported in OBP.
  9. Mixed speed DIMMs in different banks serving the same CPU run at the lower speed.

Installation Notes

  1. The minimum requirement is two DIMMs.
  2. Install the first SB1500 DIMMs in DIMM0 and DIMM1 or DIMM2 and DIMM3.
  3. Install the first SB2500 DIMMs in CPU0 DIMM2 and DIMM3.
  4. Install the first V210 DIMMs in CPU0 B0/D0 and B0/D1 or B1/D0 and B1/D1.
  5. Install the first V240 DIMMs in CPU0 B0/D0 and B0/D1 or B1/D0 and B1/D1.
  6. Install the first V250 DIMMs in CPU0 DIMM0 and DIMM1.
  7. Install the first V440 DIMMs in CPU0 B0/D0 and B0/D1 or B1/D0 and B1/D1.
  8. Install the first Netra 240 DIMMs in CPU0 B0/D0 and B0/D1.
  9. Install the first Netra 440 DIMMs in CPU0 B0/D0 and B0/D1 or B1/D0 and B1/D1.

OBP Requirements

   
System SPD 1.0 DDR266 DDR333 Mixed Pairs Mixed Banks
DDR266/333
SB1500 4.9v5 4.9v5 4.9v5 Not Supported 4.16v1**
SB2500 4.9v5 4.9v5 4.9v5 Not Supported 4.16v1**
V210/V240 4.11v4 4.11v4 4.11v4 Not Supported 4.16v1**
V250 4.11v4 4.11v4 4.11v4 Not Supported 4.16v1**
V440 4.10v10 4.10v10 4.13.v2 Not Supported 4.16v1**
Netra 240* 4.11v4 4.11v4 4.11v4 Not Supported 4.16v1**
Netra 440* 4.10v10 4.10v10 4.13v2 Not Supported 4.16v1**
* The first Netra 240 OBP was 4.11v4. The first Netra 440 OBP was 4.13v0.
** System Board FRUs without OBP 4.16v1 may require removal of mixed banks until OBP is updated.

1GB DIMM Note

  1. Sun Fire V210 systems with the following manufacturing part numbers require Fan Upgrade Kit X7418A when upgrading to 1GB DIMMs:
    602-2307-01
    602-2307-02
    602-2394-01
    602-2394-02
  2. The manufacturing part number can be found on a sticker on the right rear side of the system (as seen from the front).

Open Boot PROM Notes

  1. Serial Presence Detect 1.0 support is required. (BugID 4893067)
  2. The Sun Blade 1500 requires OBP >=4.9 Version 5.
  3. The Sun Blade 2500 requires OBP >=4.9 Version 5.
  4. The Sun Fire V210/V240 and Netra 240 require OBP >=4.11 Version 4.
  5. The Sun Fire V440 and Netra 440 require OBP >=4.10 Version 10.
    (The first Netra 440 OBP was 4.13 Version 0.)
  6. See Boot PROM page for further information about ALOM requirements.

UltraSPARC IIIi Notes

  1. The Memory Control Unit is integrated in the UltraSPARC IIIi.
  2. UltraSPARC IIIi supports 128MB to 1GB single bank DIMMs.
  3. UltraSPARC IIIi supports 256MB to 2GB dual bank DIMMs.
  4. Two DIMMs of the same bank size (single or dual) and memory size form a bank.
  5. Memory error reporting identifies a failing Bank, not a single failing DIMM.
  6. If a memory bank is mixed with single bank and dual bank DIMMs, the memory bank will fail POST. Always replace DIMMs as a pair in the same bank. Do not move single DIMMs between banks unless all DIMMs are identified as the same.

References

  1. Sun Fire V210 and V240 Administration Guide, 816-4826.
  2. Sun Fire V210 and V240 Parts Replacement Manual, 817-0743.
  3. Netra 240 Server Installation Guide, 817-2698.
  4. Netra 240 Server Service Manual, 817-2699.
  5. Netra 440 Server Installation Guide, 817-3882.
  6. Netra 440 Server Service Manual, 817-3883.
  7. Sun Blade 2500 Service, Diagnostics, and Troubleshooting Manual, 816-0996.
  8. Sun Blade 1500 Service, Diagnostics, and Troubleshooting Manual, 816-7564.
  9. Sun Fire V440 Server Installation Guide, 816-7727.
  10. Sun Fire V440 Server Administration Guide, 816-7728.
  11. Sun Fire V440 Server Parts Installation and Removal Guide, 816-7729.
  12. Sun Fire V440 Server Product Notes, 816-7733.
  13. Sun Fire V250 Server Installation Guide, 817-0899.
  14. Sun Fire V250 Server Administration Guide, 817-0900.
  15. Sun Fire V250 Server Parts Replacement Manual, 817-0901.



Sun Fire V125 / V210 / V240 / V440
Sun Blade 1500 (Red & Silver)
Sun Blade 2500 (Red & Silver)
Sun Blade SX1500 / SX2500
Netra 240 / 440

Options 5502 / 5503 / 5504
Options 7702 / 7703 / 7704 / 7711
Options 7702A-4 / 7703A-4 / 7704A-4 / 7711A-4

370-7680 370-7670 370-7671 370-7672
DDR266/333, PC2100/2700
ECC, SPD 0.0 or 1.0
256MB Registered DIMM
512MB Option 7702
512MB FRU F540-6399

Only supported on:
V210/V240
SB1500 (Red)
Netra 240
DDR266/333, PC2100/2700
ECC, SPD 0.0 or 1.0
512MB Registered DIMM
1GB Option 7703
2GB Option 5502
1GB FRU F540-6400

Not supported on:
V125
DDR266/333, PC2100/2700
ECC, SPD 0.0 or 1.0
1GB Registered DIMM
2GB Option 7704
4GB Option 5503
2GB FRU F540-6401

See 1GB DIMM Note below

Not supported on:
V125
DDR266/333, PC2100/2700
ECC, SPD 0.0 or 1.0
2GB Registered DIMM
4GB Option 7711
8GB Option 5504
4GB FRU F540-6402

Only supported on:
SB1500 (Silver)
SB2500 (Silver)
Netra 440
Sun Fire V440


See 370-7672
directly below
371-1115 371-1116 371-1117 370-7672
DDR266/333, PC2100/2700
ECC, SPD 0.0 or 1.0
256MB Registered DIMM
512MB Option 7702A-4
512MB FRU F540-6775
L

Only supported on:
V210/V240
Netra 240
DDR266/333, PC2100/2700
ECC, SPD 0.0 or 1.0
512MB Registered DIMM
1GB Option 7703A-4
1GB FRU F540-6776
1GB FRU F540-6229
1GB FRU F540-6400
L

Only supported on:
V125/V210/V240/V440
Netra 210, 240, 440
DDR266/333, PC2100/2700
ECC, SPD 0.0 or 1.0
1GB Registered DIMM
2GB Option 7704A-4
2GB FRU F540-6777
2GB FRU F540-6230
2GB FRU F540-6401
L

Only supported on:
V125/V210/V240/V440
Netra 210, 240, 440
DDR266/333, PC2100/2700
ECC, SPD 0.0 or 1.0
2GB Registered DIMM
4GB Option 7711A-4
4GB FRU F540-6402
L

Only supported on:
V125
V210 (1.33GHz)
V240 (1.33/1.5GHz)
V440


See 370-7672
directly above

Notes

  1. Bank, Rank, DIMM, and XOR Interleaving is supported.
  2. Options include two DIMMs from the same vendor with the same SPD and speed.
  3. FRUs include two DIMMs from the same vendor with the same SPD and speed.
  4. Only CPU 0 DIMMs are accessible in a single CPU system (CPU 0).
  5. Memory is mapped globally and is accessible by any CPU in a multi-CPU system.
  6. Do Not mix DIMM speeds, manufacturers, or part numbers in the same bank.
  7. Mixed speed or mixed SPD DIMMs on the same board is supported in OBP.
  8. Mixed speed or mixed SPD DIMMs in the same bank is not supported in OBP.
  9. Mixed speed DIMMs in different banks serving the same CPU run at the lower speed.
  10. 2GB DIMMs are only supported on the faster processor speeds in V210 and V240:
    V210 (1.33Ghz)
    V240 (1.33/1.5Ghz)

FRU Notes

  1. DIMM 371-1116 was added to 540-6229 and 540-6400 in October 2007. (WO_37720)
  2. DIMM 371-1117 was added to 540-6230 and 540-6401 in October 2007. (WO_37720)
  3. DIMMs 371-1116 and 371-1117 are not qualified for use in the Sun Blade 1500.
  4. DIMMs 371-1116 and 371-1117 are not qualified for use in the Sun Blade 2500.

Installation Notes

  1. The minimum requirement is two DIMMs.
  2. Install the first SB1500 DIMMs in DIMM0 and DIMM1 or DIMM2 and DIMM3.
  3. Install the first SB2500 DIMMs in CPU0 DIMM2 and DIMM3.
  4. Install the first V210 DIMMs in CPU0 B0/D0 and B0/D1 or B1/D0 and B1/D1.
  5. Install the first V240 DIMMs in CPU0 B0/D0 and B0/D1 or B1/D0 and B1/D1.
  6. Install the first V440 DIMMs in CPU0 B0/D0 and B0/D1 or B1/D0 and B1/D1.
  7. Install the first Netra 240 DIMMs in CPU0 B0/D0 and B0/D1.
  8. Install the first Netra 440 DIMMs in CPU0 B0/D0 and B0/D1 or B1/D0 and B1/D1.

OBP Requirements

   
System SPD 1.0 DDR266 DDR333 Mixed Pairs Mixed Banks
DDR266/333
SB1500 4.9v5 4.9v5 4.9v5 Not Supported 4.16v1**
SB2500 4.9v5 4.9v5 4.9v5 Not Supported 4.16v1**
V210/V240 4.11v4 4.11v4 4.11v4 Not Supported 4.16v1**
V440 4.10v10 4.10v10 4.13.v2 Not Supported 4.16v1**
Netra 240* 4.11v4 4.11v4 4.11v4 Not Supported 4.16v1**
Netra 440* 4.10v10 4.10v10 4.13v2 Not Supported 4.16v1**
* The first Netra 240 OBP was 4.11v4. The first Netra 440 OBP was 4.13v0.
** System Board FRUs without OBP 4.16v1 may require removal of mixed banks until OBP is updated.

1GB DIMM Note

  1. Sun Fire V210 systems with the following manufacturing part numbers require Fan Upgrade Kit X7418A when upgrading to 1GB DIMMs:
    602-2307-01
    602-2307-02
    602-2394-01
    602-2394-02
  2. The manufacturing part number can be found on a sticker on the right rear side of the system (as seen from the front).

UltraSPARC IIIi Notes

  1. The Memory Control Unit is integrated in the UltraSPARC IIIi.
  2. UltraSPARC IIIi supports 128MB to 1GB single bank DIMMs.
  3. UltraSPARC IIIi supports 256MB to 2GB dual bank DIMMs.
  4. Two DIMMs of the same bank size (single or dual) and memory size form a bank.
  5. Memory error reporting identifies a failing Bank, not a single failing DIMM.
  6. If a memory bank is mixed with single bank and dual bank DIMMs, the memory bank will fail POST. Always replace DIMMs as a pair in the same bank. Do not move single DIMMs between banks unless all DIMMs are identified as the same.

Sun Fire V125 Notes

  1. Factory configurations with 512MB DIMMs may include 370-7972 or 371-1116.
  2. DIMM 370-7972 is a manufacturing substitute for 370-1116 in V125 assembly 602-3652-01.

X-Option X7703A-4/X7704A-4/X7711A-4 Notes

Primary and substitute manufacturing parts changed in August 2007. (WO_35640)
370-7972 became the primary and 371-1116 became the substitute.
370-7973 became the primary and 371-1117 became the substitute.
370-7974 became the primary and 370-7672 became the substitute.

References

  1. Sun Fire V210 and V240 Administration Guide, 816-4826.
  2. Sun Fire V210 and V240 Parts Replacement Manual, 817-0743.
  3. Netra 240 Server Installation Guide, 817-2698.
  4. Netra 240 Server Service Manual, 817-2699.
  5. Netra 440 Server Installation Guide, 817-3882.
  6. Netra 440 Server Service Manual, 817-3883.
  7. Sun Blade 2500 Service, Diagnostics, and Troubleshooting Manual, 816-0996.
  8. Sun Blade 1500 Service, Diagnostics, and Troubleshooting Manual, 816-7564.
  9. Sun Fire V440 Server Installation Guide, 816-7727.
  10. Sun Fire V440 Server Administration Guide, 816-7728.
  11. Sun Fire V440 Server Parts Installation and Removal Guide, 816-7729.
  12. Sun Fire V440 Server Product Notes, 816-7733.
  13. Sun Fire V250 Server Installation Guide, 817-0899.
  14. Sun Fire V250 Server Administration Guide, 817-0900.
  15. Sun Fire V250 Server Parts Replacement Manual, 817-0901.

  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback