Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback



Memory Mezzanine

Servers: Sun Fire X4450
Telco: Netra X4450


371-3460 540-7382 540-7603
Memory Mezzanine
Assembly/FRU
Mezzanine + Tray
Netra X4450 FRU
Mezzanine + Tray

Sun Fire X4450 Codename: Tucani
Netra X4450 Codename: Argo

Notes

  1. Install memory in matched pairs.
  2. Memory FRUs include two matched DIMMs.
  3. Sun Fire X4450 DIMMs are not labeled with the FRU part number.
  4. Quantity and size of components are dependent on DIMM size and manufacturer.

Sun Fire X4450 Notes

  1. Install the largest capacity memory in the lowest numbered slots.
  2. Install Memory Filler 371-3651 in all unused slots.
  3. Install the first DIMM pair in slots A0/B0. Install the second pair in slots C0/D0.
  4. Install additional memory in slots
      A1/B1, C1/D1, A2/B2, C2/D2, A3/B3, C3/D3, A4/B4, C4/D4,
      A5/B5, C5/D5, A6/B6, C6/D6, A7/B7, and C7/D7.
  5. The Memory Mezzanine is not labeled with the FRU part number.
  6. A 3mm allen wrench is required to remove the Memory Riser cap-head screws.

Netra X4450 Notes

  1. Install the largest capacity memory in the lowest numbered slots.
  2. Install the first DIMM pair in slots A0/B0. Install the second pair in slots C0/D0.
  3. Install additional memory in slots A1/B1, C1/D1, A2/B2, C2/D2, A3/B3, C3/D3,
    A4/B4, C4/D4, A5/B5, C5/D5, A6/B6, C6/D6, A7/B7, and C7/D7.
  4. The Memory Mezzanine is not labeled with the FRU part number.

References

  1. Sun Fire X4450 Server Product Notes, 820-2703.
  2. Sun Fire X4450 Server Service Manual, 820-2707.
  3. Sun Fire X4450 Server Installation Guide, 820-2709.
  4. Netra X4450 Installation Guide, 820-4015.
  5. Netra X4450 Service Manual, 820-4017.
  6. Netra X4450 Product Notes, 820-4018.

  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.