| Level 2 Repeater
 
| Servers: | Sun Fire 4800, 4810, 6800, E4900, E6900 |  
 Option 4070
| 501-4953 |  
| Assembly/FRU January 2001
 SF 48x0/6800 only
 |  
| 501-6413 | 501-6413-07 | 501-6418 | 501-6418-07 |  
| L2 Repeater FAB 270-6413
 February 2003
 | L2 Repeater FAB 270-7088
 February 2007
 | Assembly/FRU FAB 270-6413
 February 2003
 | Assembly/FRU FAB 270-7088
 February 2007
 |  
  Notes
The minimum UltraSPARC III operating system is Solaris 8 4/01.
The minimum UltraSPARC IV operating system is Solaris 8 2/04 or
    Solaris 9 4/04.
Repeater Board slots are labeled RP0 through RP3.
Repeater Board Filler 540-4042 is not ECO released.
L2 Repeater 501-4953 is not qualified in the E4900 and E6900.
 FRU Notes
F501-4953-08 and -09 included L2 Repeater 501-4953.
F501-4953-10 Rev 50 (February 2003) included L2 Repeater 501-6418.
F501-4953-10 Rev 51 (April 2003) includes L2 Repeater 501-4953.
F501-6418 (April 2003) includes L2 Repeater 501-6418.
 References
 Sun Fire Systems Service Manual, 805-7363. Sun Fire 6800/4810/4800/3800 Systems Platform Administration Manual, 805-7373. Sun Fire Midrange Systems Platform Administration Manual, 817-2971. Sun Fire E4900/E6900 Service Manual, 817-4120. Sun Fire Systems Platform Administration Manual Firmware 5.17, 817-5243. 
 
 
 Level 2 Repeater
 
| Servers: | Sun Fire 4800, 4810, 6800, E4900, E6900 |  
 
| 501-7335-01 | 501-7335-02 | 501-7231-01 | 501-7231-02 |  
| L2 Repeater FAB 270-6413
 April 2006
 L
 | L2 Repeater FAB 270-7088
 March 2007
 L
 | Assembly/FRU FAB 270-6413
 April 2006
 L
 | Assembly/FRU FAB 270-7088
 March 2007
 L
 |  
  Notes
The minimum UltraSPARC III operating system is Solaris 8 4/01.
The minimum UltraSPARC IV operating system is Solaris 8 2/04 or
    Solaris 9 4/04.
The minimum UltraSPARC IV+ operating system is Solaris 9 9/05 or
    Solaris 10 3/05 HW1.
Repeater Board slots are labeled RP0 through RP3.
L2 Repeater 501-7231 ships in the E4900,L and E6900,L.
 References
 Sun Fire Systems Service Manual, 805-7363. Sun Fire 6800/4810/4800/3800 Systems Platform Administration Manual, 805-7373. Sun Fire Midrange Systems Platform Administration Manual, 817-2971. Sun Fire E4900/E6900 Service Manual, 817-4120. Sun Fire Systems Platform Administration Manual Firmware 5.17, 817-5243. 
 
 
 Level 2 Repeater
 
| Servers: | Sun Fire 4800, 4810, 6800, E4900, E6900 |  
 Option XE6900-FP-SWITCH-Z
| 501-7595-01 | 501-7595-02 | 501-7594-01 | 501-7594-02 |  
| L2 Repeater FAB 270-6413
 May 2006
 L
 | L2 Repeater FAB 270-7088
 March 2007
 L
 | Assembly/FRU FAB 270-6413
 May 2006
 L
 | Assembly/FRU FAB 270-7088
 March 2007
 L
 |  
  Notes
The minimum UltraSPARC III operating system is Solaris 8 4/01.
The minimum UltraSPARC IV operating system is Solaris 8 2/04 or
    Solaris 9 4/04.
The minimum UltraSPARC IV+ operating system is Solaris 9 9/05 or
    Solaris 10 3/05 HW1.
Repeater Board slots are labeled RP0 through RP3.
L2 Repeater 501-7594 supports multiple domains in Sun Fire 6800 and E6900.
L2 Repeater 501-7594 requires OBP 5.20.1.
XE6900-FP-SWITCH-Z includes four 501-7594 L2 Repeaters.
    OBP 5.20.1 is required.
The SC showboards command identifies 501-7594 as Repeater Board V2.
Do not mix 501-4953, 501-6418, or 501-7231 with 501-7594.
 References
 Sun Fire Systems Service Manual, 805-7363. Sun Fire 6800/4810/4800/3800 Systems Platform Administration Manual, 805-7373. Sun Fire Midrange Systems Platform Administration Manual, 817-2971. Sun Fire E4900/E6900 Service Manual, 817-4120. Sun Fire Systems Platform Administration Manual Firmware 5.17, 817-5243. Sun Fire 6800/E6900 Repeater Board Installation Guide, 819-5993. 
 |