| SunPCi II
 
| Workstations: | Ultra 5, 10, 30, 60, 80, 450 Sun Blade 100, 1000, 2000
 |  
| Servers: | Enterprise 250, 450, 220R, 420R Sun Fire 280R
 |  Option 2131
| 375-0131 |  
| 3.3/5V 64Bit 33MHz |   
 Jumper Settings
| JUMPER | PINS | SETTING | DESCRIPTION |  
| J5 | 1-2 3-4
 5-8
 | Out In
 Out
 | 1.5V CPU core voltage 1.5V CPU core voltage
 1.5V CPU core voltage
 |  
| J5 | 1-8 | Out | 1.5V CPU core voltage |  
| J9 | 1-2 3-4
 | Out Out
 | Standalone thermal measurement Standalone thermal measurement
 |  
| JP1 | 1-2 3-4
 5-6
 7-8
 | In In
 In
 In
 | 66.7MHz CPU/33.3MHz PCI/100MHz SDRAM 66.7MHz CPU/33.3MHz PCI/100MHz SDRAM
 66.7MHz CPU/33.3 PCI/100 SDRAM
 66.7MHz CPU/33.3MHz PCI clock
 |  
| JP2 | 1-2 | Out | Diagnostic |  
| JP3 | 1-2 | Out | Debug |  
| JP5 | 1-2 | Out | Unknown |  Notes
The minimum operating system is Solaris 2.6.
Windows 95, Windows NT Server, and Windows 2000 Server are not
    supported by SunPCi 2.0 software.
SunPCi does not fit into Ultra 5, Slot 2 or Ultra 80, Slot 4.
RS-232 signal levels are used. RS-423 is not available.
The Parallel/Serial Port Backpanel is part number 540-4086.
The Parallel/Serial Port Backpanel requires an adjacent PCI slot
    on the component side of the SunPCi II.
 Memory Notes
SunPCi II ships with one 64MB SODIMM in Slot DIMM 1.
The 64MB SODIMM does not have a Sun part number.
Sun part number 370-4294 is the 128MB SODIMM, Option 7042.
Sun part number 370-4295 is the 256MB SODIMM, Option 7044.
 References
 SunPCi II User's Guide, 806-4787. SunPCi II Installation Guide, 806-4788. Read Me First, 806-4789. SunPCi II SODIMM Installation Guide, 806-5765. 
 |