LED/Switch Board
Disk Arrays: |
Storage 7210, J4500 |
Servers: |
Sun Fire X4500, X4540 |
501-7192 |
LED/Switch Board L |
Storage 7210 Codename: Fugu
Storage J4500 Codename: Loki
Sun Fire X4500 Codename: Thumper
Sun Fire X4540 Codename: Thor |
Notes
- There is only 50 mm of clearance between the board and the fan cover hinge.
- A stubby screwdriver will not fit between the board and the fan cover hinge.
- A standard length screwdriver can not be positioned at the proper angle.
- Use a right angled #1 Phillips screwdriver to loosten the three retaining
screws.
- The screws are stainless steel and will not adhear to a magnetic tip
screwdriver.
- Use caution not to drop screws into the chassis. They are difficult to
remove.
- The LED/Switch Board and cable is included with X4500 Chassis FRU 541-1907.
- The LED/Switch Board FRU F501-7192 includes Cable 530-3819.
References
-
Sun Fire X4500 Server Installation Guide, 819-4358.
-
Sun Fire X4500/X4540 Server Service Manual, 819-4359.
-
Sun Fire X4500 Server Diagnostics Guide, 819-4363.
-
Sun Fire X4500 Server Product Notes, 819-4364.
-
Sun Fire X4500/X4540 Server Administration Guide, 819-6562.
-
Sun Fire X4500/X4540 Server Installation Guide, 820-4855.
-
Integrated Lights-Out Manager Administration Guide for ILOM 1.0, 819-1160.
-
Integrated Lights-Out Manager Administration Guide for ILOM 1.1.1, 820-0280.
-
Sun Fire X4500/X4540 Server Integrated Lights Out Manager (ILOM) Supplement, 819-4361.
-
Storage J4500 Array Service Manual, 820-3160.
-
Storage J4500 Array Product Notes, 820-3162.
-
Sun Storage 7210 Unified Storage System Installation Guide, 820-3757.
-
Sun Storage 7210 Unified Storage System Service Manual, 820-4160.
|