Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback



Raid Controller

Disk Arrays: StorEdge A1000

375-0007 375-0015 375-0016
8MB MPU Memory
16MB RPA Memory
w Battery
16MB MPU Memory
64MB RPA Memory
FRU w/o Battery
8MB MPU Memory
16MB RPA Memory
FRU w/o Battery
375-0134 375-0135 375-0136
8MB MPU Memory
16MB RPA Memory
w Battery
8MB MPU Memory
16MB RPA Memory
FRU w/o Battery
16MB MPU Memory
64MB RPA Memory
FRU w/o Battery
See Firmware Notes below.

Switch and Jumper Settings

LOCATION PINS SETTING DESCRIPTION
E1 1-2 In Unknown
E2 1-2 Out Unknown
E3 1-2 In Unknown
E4 1-2 Out Unknown
E5 1-2 In Unknown
E6 1-2 In Unknown
E7 1-2 Out Unknown
SW1 0-f As required SCSI ID
SW2 1-4 Off Diag
StorEdge A1000 Codename: Dilbert

Notes

  1. The minimum operating system is Solaris 2.5.1 Hardware: 8/97.
  2. The M48T59 NVRAM uses an M4T28 SNAPHAT battery.

Memory Notes

  1. The RAID Controller uses Extended Data Out SIMMs.
  2. The 32MB RPA SIMM is Sun Part Number 370-2439-01.
  3. The 4MB MPU SIMM has no Sun part number.
  4. The 8MB MPU or RPA SIMM has no Sun part number.
  5. Install 8MB or 32MB RPA SIMMs in slots SIMM-1 and SIMM-2.
  6. Install 4MB or 8MB MPU SIMMs in slots SIMM-3 and SIMM-4.

Firmware Notes

  1. Firmware on 375-0007, 375-0015, and 375-0016 is compatible with RAID Manager 6.1.1.
    This controller firmware is not compatible with RAID Manager 6.22.
  2. Firmware on 375-0134, 375-0135, and 375-0136 is compatible with RAID Manager 6.22.
    This controller firmware is not compatible with RAID Manager 6.1.1.

Reference

A1000 Installation, Operation, and Service Manual, 805-2624.

  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback