Serial Attached SCSI HBA
370-7696 |
LSI Logic SAS3041XL-S
PCI/PCI-X 3.3V 32/64Bit
33/66/100/133MHz |
Sun Fire T2000 Notes
- SAS HBA 370-7696 is only used in the pre-RoHS Sun Fire T2000.
(The RoHS T2000 has onboard SAS.)
- The SAS HBA connects to the SAS Backplane and controls the internal
disk drives.
- The SAS HBA is factory installed in Slot PCI-X 0 and includes
a Low Profile Bracket.
- To replace SAS cable set 530-3446, order Cable Kit 530-3399.
- SAS cables 530-3442/3443/3444/3445 are shrink wrapped together.
- SAS cables are labeled HDD on the Backplane end and
PHY on the HBA end.
References
-
Sun Fire T2000 Service Manual, 819-2548.
- LSI SAS PCI/PCI-X Host Adapters User's Guide, LSI Logic DB15-000333.
- LSI SAS1064 Controller Technical Manual, LSI Logic DB14-000274.
Serial Attached SCSI HBA
370-7592-05 |
371-2301-01 |
370-7592-06 |
Assembly 411737000033 FRUID 370-7592 2MB Flash
January 2006 L |
Assembly 411737000033 FRUID 370-2301 4MB Flash
October 2006 L |
Assembly 411737000033 FRUID 370-7592 4MB Flash
February 2007 L |
370-7677-05 |
370-7677-06 |
370-7677-07 |
Assembly/FRU with 370-7592-05
January 2006 L |
Rev 50 Assembly/FRU with 371-2301-01
October 2006 L |
Rev 51 Assembly/FRU with 371-7592-06
February 2007 L |
Netra 210 Notes
- The HBA plugs into the Netra 210 System Board at J10 and J11.
- The HBA connects to the Disk Backplane with one Red and
one Yellow SAS Cable.
- One Red and one Yellow SAS Cable are included in Cable Set 371-0119.
- There is no part number for the plastic System Board mounting standoff.
- FRU F370-7677 includes the SAS HBA and the SAS Cable Set.
- SAS HBA 371-2301 changed to 371-7692-06 in February 2007.
(WO_35053)
- Netra 210 ALOM 1.5.4 and OBP 4.22.19 do not recognize FRUID 371-2301.
References
-
Netra 210 Server System Administration Guide, 819-2749.
-
Netra 210 Server Service Manual, 819-2750.
-
Netra 210 Server Product Notes, 819-2751.
- LSI SAS PCI/PCI-X Host Adapters User's Guide, LSI Logic DB15-000333.
- LSI SAS1064 Controller Technical Manual, LSI Logic DB14-000274.
Serial Attached SCSI HBA
371-1490 |
LSI Logic SAS3080L-S PCI/PCI-X 3.3V 32/64Bit
33/66/100/133MHz L |
Notes
- The SAS HBA is factory installed in Slot PCI-X 4.
- The HBA connects to the Disk Cable Board 501-7245 and to the SAS Backplane.
- To replace SAS Cable 530-3461, order Cable Kit 560-2849.
- The RAID activate-volume function requires FCode 1.0.39, which can be found in patch 123485-01.
References
-
Sun Fire V445 Server Administration Guide, 819-3741.
-
Sun Fire V445 Server Service Manual, 819-3742.
-
Sun Fire V445 Server Installation Guide, 819-3743.
-
Sun Fire V445 Server Product Notes, 819-3744.
-
Sun Fire V445 Server Supplemental Product Notes, 819-7846.
|