SCSI RAID Controller (SRC/P)
Servers: |
Enterprise 250, 450, 220R, 420R
Sun Fire 280R |
Telco: |
Netra 20 |
Options 6542 / 6602
375-0078 |
DPT SmartRAID Millennium PM3755U2B
w Battery Backup Module BB4050
w SCSI Expansion Module SX4055U2-2
w 64MB ECC EDO DIMM DM4050-64
3.3/5V 64Bit 33MHz |
Notes
- The minimum operating system is Solaris 2.6 Hardware: 3/98.
- SRC/P on Solaris 9 requires Patch 115548-01.
- The E250 and E450 require OBP >=3.12.
- The SRC/P requires a 64-Bit PCI slot.
- Internal Option 6602 is only available for the Enterprise 450 (A25).
- The maximum high-speed disk cache memory is 256MB.
Cable Notes
- The Enterprise 450 requires internal 8-Disk Backplane Cable 530-2744.
- The 68-pin VHDCI connector on Cables 530-2452-01 and 530-2453-01
is centered in the housing.
- The 68-pin VHDCI connector on Cables 530-2452-02 and 530-2453-02
is offset in the housing.
- Cables with centered VHDCI connectors are not usable at the same time
on the A and B ports, due to the thickness of the connector shell.
The shell thickness was reduced on cables 530-2452-02 and 530-2453-02.
- Cable 530-2453-02 was released in May 1999.
- Cable 530-2452-02 was released in May 2001.
References
-
SRC/P Installation Guide, 805-7752.
-
SRC/P User's Guide, 805-6768.
-
E450 Internal RAID Storage Option Installation Guide, 805-6765.
|