 Netra CP2040CP2040S-500
| 501-5721 |  
| 500MHz 0MB FRU
 w Front Panel
 |  
  Jumper Settings
| SWITCH | DIP | SETTING | DESCRIPTION |  
| SW0501 | 1 2
 | On On
 | SMC setting for non-HA system |  
| 1 2
 | Off On
 | SMC setting for HA system |  
| SW1801 | 1 2
 | Off Off
 | Boot Flash PROM selected (default) |  
| 1 2
 | On On
 | User Flash PROM 1 selected |  
| 1 2
 | Off On
 | User Flash PROM 1 and 2 selected |  
| 1 2
 | On Off
 | ROMBO selected |  
| SW2401 | 1 1
 | Off On
 | SCSI Bus A Termination Power enabled SCSI Bus A Termination Power disabled
 |  
| 2 2
 | Off On
 | SCSI Bus B Termination Power enabled SCSI Bus B Termination Power disabled
 |  
| 3 3
 | Off On
 | SCSI Bus A Termination enabled SCSI Bus A Termination disabled
 |  
| 4 4
 | Off On
 | SCSI Bus B Termination enabled SCSI Bus B Termination disabled
 |  Notes
The Hostid and MAC address are in I2C SEEPROM 100-6223 at U3209.
Use 256MB Memory mezzanine 375-3024, Option XCP2000-MEM-256.
Use 512MB Memory mezzanine 375-3025, Option XCP2000-MEM-512.
Use 1GB Memory mezzanine 375-3026, Option XCP2000-MEM-1GB.
Use Rear Transition Card 375-0121, Option XCP2040-TRN.
Use Rear Transition Card 375-3429, L, Option XCP2040-TRN-4.
High Availability (HA) systems use the BD_SEL, HEALTHY, and PCI-RST
    signals to control each slot.
 Reference
 Netra CP2040 Technical Reference Manual, 806-4994. 
 |