 StorEdge 5210 NAS / 5310 NAS
| 375-3209 |  
| PBA A99386-112 Intel SE7501WV2
 370-6171 w/o BIOS/Firmware
 MAC Address 0007e9xxxxxx
 |   
 Headers and Jumpers
| LOCATION | PINS | SETTING | DESCRIPTION |  
| J1A1 | 2 | NA | HDD LED - not used |  
| J1D3 | 10 | NA | USB Cable to LDC Module and Operator Panel |  
| J1G1 | 34 | NA | Floppy - not used |  
| J1G2 | 40 | NA | IDE - 256MB Flash Card 375-3214 |  
| J1G4 | 34 | NA | Front Panel - not used |  
| J1H1 | 24 | NA | NMI/RST/LED - not used |  
| J1J1 | 5 | NA | I2C to Power Distribution Board |  
| J2G1 | 6 | NA | Floppy/Front Panel/IDE |  
| J2J1 | 6 | NA | Fan Tray Power |  
| J3J1 | 24 | NA | Power to Power Distribution Board |  
| J3J2 | 12 | NA | Fan Tray Power |  
| J4J1 | 8 | NA | 12V to Power Distribution Board |  
| J4J2 | 2 | NA | CPU1 Fan - not used |  
| J7A2 | 2 | NA | Chassis Int - not used |  
| J7B1 | 68 | NA | SCSI - not used |  
| J7J1 | 2 | NA | CPU2 Fan - not used |  
| J9A2 | 10 | NA | Serial Port A - not used |  
| J9B1 | 5 | NA | ICMB - not used |  
| J9C1 | 3 | NA | IPMB - not used |  
| J1D4 | 1-2 2-3
 5-6
 6-7
 9-10
 10-11
 | In In
 In
 In
 In
 In
 | Normal CMOS Operation (default) Clear CMOS
 Normal Password Operation (default)
 Clear Password
 Normal BIOS Operation (default)
 BIOS Recovery
 |  
| J4B2 | 1-2 2-3
 | Out In
 | BMC Boot Block Write Enabled BMC Boot Block Write Protected (default)
 |  
| J5A2 | 1-2 3-4
 | In In
 | DCD connected to Serial Port Pin-7 DSR connected to Serial Port Pin-7 (default)
 |  
 
| StorEdge 5210 NAS Codename: Audi StorEdge 5310 NAS Codename: Mustang
 |  Notes
The System Board is not a Field Replacable Unit.
The StorEdge 5210 NAS includes internal disk drives.
The StorEdge 5310 NAS does not include internal disk drives.
 References
 StorEdge 5210 NAS Release Notes, 817-6657. StorEdge 5210 NAS Quick Reference Manual, 817-6659. StorEdge 5210 NAS Hardware Installation, Configuration, and User Guide, 817-6660. StorEdge 5210 NAS Software Installation, Configuration, and User Guide, 817-6661. 
 |