Sun Blade X6275 IB
| 375-3603 |
540-7835 |
X6275-AA |
System Board
|
Assembly/FRU 375-3603 +
Svc Proc 375-3611
|
X6275 Base 540-7835 |
Headers, Jumpers, and Switches
| CODE |
LOCATION |
PINS |
SETTING |
DESCRIPTION |
| A |
J2 |
4 |
Out |
Not documented |
| B |
J3 |
1-2 3-4 |
Out Out |
Node0 FMD Discharge when installed
Node1 FMD Discharge when installed |
| C |
J11-1 |
4 |
Out |
Not documented (Node0) |
| D |
J11-2 |
4 |
Out |
Not documented (Node1) |
| E |
J13_1 |
1-2 |
Out |
Not documented (Node0) |
| F |
J13_2 |
1-2 |
Out |
Not documented (Node1) |
| G |
J16_1 |
2-3 |
In |
Not documented (Node0) |
| H |
J16_2 |
2-3 |
In |
Not documented (Node1) |
| I |
J18_1 |
2-3 |
In |
Not documented (Node0) |
| J |
J18_2 |
2-3 |
In |
Not documented (Node1) |
| K |
J22_1 |
3 |
Out |
Not documented (Node0) |
| L |
J22_2 |
3 |
Out |
Not documented (Node1) |
| M |
J29_1 |
10 |
Out |
Not documented (Node0) |
| N |
J29_2 |
10 |
Out |
Not documented (Node1) |
| O |
J31_1 |
10 |
Out |
Not documented (Node0) |
| P |
J31_2 |
10 |
Out |
Not documented (Node1) |
| Q |
J35_1 |
10 |
Out |
Not documented (Node0) |
| R |
J35_2 |
10 |
Out |
Not documented (Node1) |
| S |
J37_1 |
1-2 |
Out |
Not documented (Node0) |
| T |
J37_2 |
1-2 |
Out |
Not documented (Node1) |
| U |
J42_1 |
1-2 |
In |
Clear Node0 CMOS when 2-3 installed |
| V |
J42_2 |
1-2 |
In |
Clear Node1 CMOS when 2-3 installed |
| W |
J43_1 |
1-2 |
Out |
Not documented (Node0) |
| X |
J43_2 |
1-2 |
Out |
Not documented (Node1) |
| Y |
J44_1 |
1-2 |
Out |
Not documented (Node0) |
| Z |
J44_2 |
1-2 |
Out |
Not documented (Node1) |
| AA |
J57_1 |
1-2 |
In |
Node0 Boot Dest |
| BB |
J57_2 |
1-2 |
In |
Node1 Boot Dest |
| CC |
Jxx |
1-2 |
Out |
Not Documented / Not silkscreened |
| DD |
Jyy |
1-2 |
Out |
Not Documented / Not silkscreened |
|
SW1_1 |
n/a |
n/a |
Host Reset (Node0) |
|
SW1_2 |
n/a |
n/a |
Host Reset (Node1) |
|
SW3_1 |
n/a |
n/a |
SP CPU Reset (Node0) |
|
SW3_2 |
n/a |
n/a |
SP CPU Reset (Node1) |
|
Sun Blade X6275 Codename: Vayu |
Notes
- Heatsinks 310-0254 and 310-0255 are pre-greased with Shin-Etsu X23-7783D.
- The X6275 Blade FRU includes four 310-0065 Shin-Etsu X23-7783D syringes.
- The Sun Blade X6275 supports PCI Express 1.1 and 2.0.
- Sun Blade 6048 Midplane 501-7788 supports PCI Express 1.1.
- Sun Blade 6048 Midplanes 511-1212 and 511-1473 support PCI Express 2.0.
- The Sun Blade 6048 Midplane upgrade is B22-B-MP-UPGKIT.
Chassis Notes
- The X6275 IB is supported in Sun Blade 6048.
- The X6275 IB is not supported in Sun Blade 6000.
Memory Installation Notes
- The minimum configuration is three DIMMs per CPU in slots D1, D3, and D5.
- Memory speed is dependent on the number of DIMMs and the CPU Front Side Bus.
- Maximum speed is 1333MHz when 1333MHz DIMMs are installed in D1, D3, and D5.
- Maximum speed is 1066MHz when any speed DIMMs are installed in all slots.
- Use of the same DIMM size and speed is recommended for maximum performance.
- Node 0 and Node 1 require the same memory configuration.
References
Sun Blade X6275 Server Module Service Manual, 820-6849.
Sun Blade X6275 Server Module Product Notes, 820-6853.
Sun Blade X6275 Server Module Installation Guide, 820-6977.
Sun Blade X6275 GbE
| 375-3604 |
540-7836 |
X6275-BA |
System Board
|
Assembly/FRU 375-3604 +
Svc Proc 375-3611
|
X6275 Base 540-7836 |
Headers, Jumpers, and Switches
| CODE |
LOCATION |
PINS |
SETTING |
DESCRIPTION |
| A |
J2 |
4 |
Out |
Not documented |
| B |
J3 |
1-2 3-4 |
Out Out |
Node0 FMD Discharge when installed
Node1 FMD Discharge when installed |
| C |
J11-1 |
4 |
Out |
Not documented (Node0) |
| D |
J11-2 |
4 |
Out |
Not documented (Node1) |
| E |
J13_1 |
1-2 |
Out |
Not documented (Node0) |
| F |
J13_2 |
1-2 |
Out |
Not documented (Node1) |
| G |
J16_1 |
2-3 |
In |
Not documented (Node0) |
| H |
J16_2 |
2-3 |
In |
Not documented (Node1) |
| I |
J18_1 |
2-3 |
In |
Not documented (Node0) |
| J |
J18_2 |
2-3 |
In |
Not documented (Node1) |
| K |
J22_1 |
3 |
Out |
Not documented (Node0) |
| L |
J22_2 |
3 |
Out |
Not documented (Node1) |
| M |
J29_1 |
10 |
Out |
Not documented (Node0) |
| N |
J29_2 |
10 |
Out |
Not documented (Node1) |
| O |
J31_1 |
10 |
Out |
Not documented (Node0) |
| P |
J31_2 |
10 |
Out |
Not documented (Node1) |
| Q |
J35_1 |
10 |
Out |
Not documented (Node0) |
| R |
J35_2 |
10 |
Out |
Not documented (Node1) |
| S |
J37_1 |
1-2 |
Out |
Not documented (Node0) |
| T |
J37_2 |
1-2 |
Out |
Not documented (Node1) |
| U |
J42_1 |
1-2 |
In |
Clear Node0 CMOS when 2-3 installed |
| V |
J42_2 |
1-2 |
In |
Clear Node1 CMOS when 2-3 installed |
| W |
J43_1 |
1-2 |
Out |
Not documented (Node0) |
| X |
J43_2 |
1-2 |
Out |
Not documented (Node1) |
| Y |
J44_1 |
1-2 |
Out |
Not documented (Node0) |
| Z |
J44_2 |
1-2 |
Out |
Not documented (Node1) |
| AA |
J57_1 |
1-2 |
In |
Node0 Boot Dest |
| BB |
J57_2 |
1-2 |
In |
Node1 Boot Dest |
| CC |
Jxx |
1-2 |
Out |
Not Documented / Not silkscreened |
| DD |
Jyy |
1-2 |
Out |
Not Documented / Not silkscreened |
|
SW1_1 |
n/a |
n/a |
Host Reset (Node0) |
|
SW1_2 |
n/a |
n/a |
Host Reset (Node1) |
|
SW3_1 |
n/a |
n/a |
SP CPU Reset (Node0) |
|
SW3_2 |
n/a |
n/a |
SP CPU Reset (Node1) |
|
Sun Blade X6275 Codename: Vayu |
Notes
- Heatsinks 310-0254 and 310-0255 are pre-greased with Shin-Etsu X23-7783D.
- The X6275 Blade FRU includes four 310-0065 Shin-Etsu X23-7783D syringes.
- The Sun Blade X6275 GbE requires a PCI Express 2.0 Midplane.
- Sun Blade 6000 A90-A Midplane 501-7376 supports PCI Express 1.1.
- Sun Blade 6000 A90-B Midplane 511-1298 supports PCI Express 2.0.
- The Sun Blade 6000 Midplane upgrade is A90-B-MP-UPGKIT.
- Sun Blade 6048 Midplane 501-7788 supports PCI Express 1.1.
- Sun Blade 6048 Midplanes 511-1212 and 511-1473 support PCI Express 2.0.
- The Sun Blade 6048 Midplane upgrade is B22-B-MP-UPGKIT.
Chassis Notes
- The X6275 GbE is supported in Sun Blade 6000 A90-A and A90-B, and
in Sun Blade 6048.
- The X6275 GbE is not supported in Sun Blade 6000 A90-D.
Memory Installation Notes
- The minimum configuration is three DIMMs per CPU in slots D1, D3, and D5.
- Memory speed is dependent on the number of DIMMs and the CPU Front Side Bus.
- Maximum speed is 1333MHz when 1333MHz DIMMs are installed in D1, D3, and D5.
- Maximum speed is 1066MHz when any speed DIMMs are installed in all slots.
- Use of the same DIMM size and speed is recommended for maximum performance.
- Node 0 and Node 1 require the same memory configuration.
References
Sun Blade X6275 Server Module Service Manual, 820-6849.
Sun Blade X6275 Server Module Product Notes, 820-6853.
Sun Blade X6275 Server Module Installation Guide, 820-6977.
|