Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback



Sun Blade X6440

375-3559 540-7677 X6440-AA
System Board
System Board
Assembly/FRU
X6440 Base
540-7677
594-5967 594-5968
16GB 4 × 2.5GHz
Opteron 8380
X6440-44M2501-82
32GB 4 × 2.7GHz
Opteron 8384
X6440-44M2701-B2

Headers, Jumpers and Switches

LOCATION PINS SETTING DESCRIPTION
J? 2 Out Not documented
J1 2 Out Not documented
J2 2 Out Not documented
J3 2 Out Not documented
J4 3 Out Not documented
J6 16 Out Not documented
J7 3 2-3 In Not documented
J8 2 Out Not documented
J11 6 Out Not documented
J12 6 Out Not documented
J14 6 Out Not documented
J15 3 Out Not documented
J17 2 Out Not documented
J18 2 In Not documented
J19 2 Out Not documented
J20 2 Out Not documented
J21 2 Out Not documented
J22 2 Out Not documented
J23 2 Out Not documented
J24 2 In Not documented
J25 2 In Not documented
J27 2 Out Not documented
J29 3 1-2 In Normal CMOS (2-3 = Clear CMOS)
J30 2 Out Not documented
J31 3 2-3 In Normal (default)
J35 3 Out Not documented
J37 3 2-3 In Normal Password (1-2 = Clear SP Password)
J42 2 Out Not documented
J43 20 Out Not documented
J57 3 1-2 In Normal SP Mode (2-3 = SP Recovery Mode)
J58 3 2-3 In Not documented
J59 4 Out Not documented
SW4 n/a n/a Not documented
SW5 n/a n/a CPU and Memory Fault Remind

Sun Blade X6440 Server Module Codename: Pegasus +

Notes

  1. Install DIMMs in matched pairs in D0/D1, then D2/D3, D4/D5, and D6/D7.
  2. Heatsink 310-0159 is pre-greased with Shin-Etsu X23-7783D.

References

  1. Sun Blade X6440 Server Module Installation Guide, 820-3961.
  2. Sun Blade X6440 Server Module Service Manual, 820-3964.
  3. Sun Blade X6440 Server Module Product Notes, 820-3965.


Sun Blade X6440


375-3625 542-0142 X6440-AB
System Board System Board
Assembly/FRU
X6440 Base
542-0142

Headers and Jumpers

LOCATION PINS SETTING DESCRIPTION
Unknown 2 Out Not documented
J1 2 Out Not documented
J2 2 Out Not documented
J3 2 Out Not documented
J4 3 Out Not documented
J6 16 Out Not documented
J7 3 2-3 In Not documented
J8 2 Out Not documented
J11 6 Out Not documented
J12 6 Out Not documented
J14 6 Out Not documented
J15 3 Out Not documented
J17 2 Out Not documented
J18 2 In Not documented
J19 2 Out Not documented
J20 2 Out Not documented
J21 2 Out Not documented
J22 2 Out Not documented
J23 2 Out Not documented
J24 2 In Not documented
J25 2 In Not documented
J27 2 Out Not documented
J29 3 1-2 In Normal CMOS (2-3 = Clear CMOS)
J30 2 Out Not documented
J31 3 2-3 In Normal (default)
J35 3 Out Not documented
J37 3 2-3 In Normal Password (1-2 = Clear SP Password)
J42 2 Out Not documented
J43 20 Out Not documented
J57 3 1-2 In Normal SP Mode (2-3 = SP Recovery Mode)
J58 3 2-3 In Not documented
J59 4 Out Not documented
SW4 n/a n/a Not documented
SW5 n/a n/a CPU and Memory Fault Remind

Sun Blade X6440 Server Module Codename: Pegasus+ HT3

Notes

  1. X6440-AB is required to support AMD 6-core Opteron 8400 series processors.
  2. Install DIMMs in matched pairs in D0/D1, then D2/D3, D4/D5, and D6/D7.
  3. Thermal Grease 310-0065 is included with the System Board FRU.
  4. Heatsink 310-0159 is pre-greased with Shin-Etsu X23-7783D (310-0065).

References

  1. Sun Blade X6440 Server Module Installation Guide, 820-3961.
  2. Sun Blade X6440 Server Module Service Manual, 820-3964.
  3. Sun Blade X6440 Server Module Product Notes, 820-3965.

  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback