 Sun Fire V120 / Netra 120
 
| 375-3064 | 375-3065 |  
| 0MB FRU 550MHz US IIi
 Sun Fire V120
 February 2002
 | 0MB FRU 650MHz US IIi
 Netra 120
 Sun Fire V120
 February 2002
 |  
| 375-3198 | 375-3199 |  
| 0MB FRU 550MHz US IIi
 Sun Fire V120
 November 2003
 | 0MB FRU 650MHz US IIi
 Netra 120
 Sun Fire V120
 November 2003
 |   
 Jumper Settings
| JUMPER | PINS | SETTING | DESCRIPTION |  
| JP8 | 1-2 3-4
 | In In
 | Netra 120 setting Sun Fire V120 setting
 |  
| JP9 | 1-2 2-3
 | In In
 | Select Flash PROM (default) Select ROMBO
 |  
| JP13 | 1-2 1-2
 | Out In
 | Normal LOMlite2 operation (default) Reset LOMlite2
 |  
| JP14 | 1-2 1-2
 | Out In
 | Normal LOMlite2 operation (default) Bypass LOMlite2
 |  
| JP15 | 1-2 1-2
 | Out In
 | Normal LOMlite2 flash (default) LOMlite2 flash recovery
 |  
| JP16 | 1-2 1-2
 | Out In
 | OBP write protected OBP write enabled (default)
 |  
| JP17 | 1-2 | Out | CD-ROM set as Master ATA device |  JP7 Speed Select Jumper Settings
| 1-2 | 3-4 | 5-6 | DESCRIPTION | PART NUMBER (Codename = Phantom)
 |  
| Out | Out | In | 550MHz UltraSPARC IIi | 100-7192 |  
| Out | In | Out | 650MHz UltraSPARC IIi | 527-1023 |  
 
| Sun Fire V120 Codename: Flapjack2+ |  Notes
The minimum operating system is Solaris 8 10/01.
The hostid, MAC address, and OBP environment settings are stored
    on System Configuration Smart Card 370-4285.
375-3064, 375-3065, 375-3198, and 375-3199 are based on the
    Netra T1 System Board with faster CPU, updated OBP and LOM firmware,
    and JP8 installed.
There is no Netra 120 or Sun Fire V120 UltraSPARC IIi FRU.
 Memory Notes
The minimum memory requirement is one DIMM in Slot 0.
The memory installation sequence is Slot 0, 1, 2, and 3.
Each DIMM slot addresses 1GB with >=550MHz UltraSPARC IIi.
When equal size DIMMs are installed, the lowest slot number is
    mapped to the lowest address range.
When mixed size DIMMs are installed, the slot number with the
    largest size DIMM is mapped to the lowest address range.
 UltraSPARC IIi Notes
The 650MHz UltraSPARC IIi is similar to the 270-440MHz UltraSPARC IIi.
    Differences include integrated L2 Cache and SDRAM Memory Control.
The 650MHz UltraSPARC IIi is based on the 500MHz UltraSPARC IIe.
The 650MHz UltraSPARC IIi OBP and OS name is UltraSPARC IIe.
 References