 Sun Fire V125
| 375-3478 |  
| 0MB USIIIi FRU 1× 1.002GHz
 w Fan/Heatsink
 L
 |   
 
 
| LOCATION | PINS | SETTING | DESCRIPTION |  
| JP1 | 1-2 3-4
 9-10
 | In In
 In
 | 1.4V Core VID[4:0] Bit 4 (00110) 1.4V Core VID[4:0] Bit 3 (00110)
 1.4V Core VID[4:0] Bit 0 (00110)
 |  
| JP2 | 1-2 1-2
 | Out In
 | ALOM Flash Normal (default) ALOM Flash Recovery
 |  
| JP3 | 1-2 1-2
 | Out In
 | ALOM Normal (default) ALOM Reset
 |  
| JP4 | 1-2 | In | 1.002GHz CONFIG[2:0] Bit 0 (110) |  
| JP5 | 1-2 1-2
 | Out In
 | ATAPI Master - CSEL Open (default) ATAPI Slave - CSEL Grounded
 |  
| JP6 | 1-2 2-3
 | In/Out In
 | OBP Flash Select (default) ROMBO Select
 |  
| JP8 | 1-2 2-3
 | In In
 | Normal CMOS (default) Clear CMOS
 |  
| JP10 | 1-2 1-2
 | Out In
 | PS_ON# (default) PS_ON# Override
 |  
| JP11 | 1-2 1-2
 | Out In
 | OBP Flash Write Enabled (default) OBP Flash Write Protected
 |  
| JP12 | 1-2 1-2
 | Out In
 | ALOM Console Normal (default) ALOM Console Bypass
 |  
| JP13 | 1-2 2-3
 | In/Out In
 | OBP Flash Normal (default) OBP Flash Recovery
 |  
 
| Sun Fire V125 Codename: El Paso |  Notes
The minimum operating system is Solaris 8 2/04, Solaris 9 9/04, or
    Solaris 10 3/05.
ALOM update is available at
     Firmware Downloads.The JBUS clock is 167MHz and the Memory clock is 125MHz with
    1.002GHz CPUs.
 Memory Notes
Bank, Rank, DIMM, and XOR Interleaving is supported.
UltraSPARC IIIi supports single bank and dual bank DDR-1 SDRAM DIMMs.
Two DIMMs of the same bank size (single or dual) and memory size form a
    bank.
The minimum requirement is two DIMMs in any Bank (B0/D0/D1 or B1/D0/D1).
Only CPU 0 DIMMs are accessible in a single CPU system (CPU 0). 
Memory is mapped globally and is accessible by either CPU in a dual-CPU
    system.
Memory error reporting identifies a failing Bank, not a single failing DIMM.
 References
 Sun Fire V125 Server Administration Guide, 819-7420. Sun Fire V125 Server Service Manual, 819-7421. Sun Fire V125 Server Installation Guide, 819-7422. Sun Fire V125 Server Product Notes, 819-7424. Heatsink Field Replaceable Unit Installation Guide, 817-4048. 
 |