Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback



Sun Fire V215 / V245

375-3462 375-3463 375-3464
0MB w/out Heatsink
L
0MB USIIIi FRU
2× 1.503GHz
w/ Heatsink
L
0MB USIIIi FRU
1× 1.503GHz
w/ Heatsink
L

LOCATION PINS SETTING DESCRIPTION
J7 10 NA Unused Connector
J11 2 Out Unknown
J13 4 NA Unused Connector
J14 3 2-3 In SER2/TTYB
J15 3 2-3 In SER2/TTYB
J17 3 1-2 In Enable TTYB when Host Power On
J20/J21 5 Out Unknown
J19 2 Out Unknown
J26 6 Out Unknown
J31 2 Out Unknown
J37 6 Out Unknown
J38 3 1-2 In 1.40V CPU0 Vcore Output
J43 8 3-4 1.5GHz UltraSPARC IIIi
J45 4 NA Unused Connector
J46 2 Out Unknown
J48 3 1-2 In 1.40V CPU1 Vcore Output
J49 3 Out Unknown
J51 2 Out Unknown
J52 10 NA Unused Connector
SW1 NA NA POR Button
SW2 NA NA XIR Button
SW3 NA NA PWR Button
SW4 NA NA Unknown Button

Sun Fire V215 Codename: Seattle 1U
Sun Fire V245 Codename: Seattle 2U

Notes

  1. The minimum operating system is Solaris 9 9/05 or 10 6/06.
  2. ALOM update is available at Firware Downloads.

Memory Notes

  1. Bank, Rank, DIMM, and XOR Interleaving is supported.
  2. The minimum requirement is two DIMMs in any Bank (B0/D0/D1 or B1/D0/D1).
  3. UltraSPARC IIIi supports single bank and dual bank DDR-1 SDRAM DIMMs.
  4. Two DIMMs of the same bank size (single or dual) and memory size form a bank.
  5. Memory error reporting identifies a failing Bank, not a single failing DIMM.

References

  1. Sun Fire V215 and V245 Servers Administration Guide, 819-3036.
  2. Sun Fire V215 and V245 Servers Installation Guide, 819-3037.
  3. Sun Fire V215 and V245 Servers Service Manual, 819-3038.
  4. Sun Fire V215 and V245 Servers Product Notes, 819-3040.

  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback