| Servers: | Sun Fire X4200 M2 |   
| Telco: | Netra X4200 M2 |  
 
 
| 501-7590 | 501-7989 |  
| FAB 270-7590-02 September 2006
 L
 | FAB 270-7590-03 September 2007
 L
 |   
 
 
 
| Netra X4200 M2 Codename: Draco Sun Fire X4200 M2 Codename: Galaxy 2F
 |  Notes
The minimum Sun Fire X4200 M2 Solaris operating system is
    Solaris 10 6/06 (U2) x64.
The minimum Netra X4200 M2 Solaris operating system is
    Solaris 10 11/06 (U3) x64.
The System Board FRU includes two 310-0049 Thermal Grease Syringes.
Cable kit 565-1963 is required to program the CPLD.
The 501-7590-04 and 501-7989-02 include the CPLD change for BugID 6629455.
CPLD code was changed to allow a 25ms waiting period upon an AC power fault
    to both AC Input power supplies. The change does not apply to systems with
    DC Input power supplies which have a 10ms holdup time.
    Reference WO_38378 of January 2008.
Each CPU requires one pair of DIMMs.
Install HyperTransport Terminator 371-2481 when
    only one processor is installed.
Install DIMMs in pairs beginning with DIMM A1 and B1 then DIMM A0 and B0.
 Netra X4200 M2 References
 Netra X4200 M2 Setup Guide, 820-0062. Netra X4200 M2 Service Manual, 820-0063. Netra X4200 M2 Product Notes, 820-0067. Integrated Lights Out Manager Administration Guide, 819-1160. Integrated Lights Out Manager Administration Guide, 820-0280. Sun Fire X4200 M2 References
 Sun Fire X4100 and X4200 Installation Guide, 819-1155. Sun Fire X4100 and X4200 Service Manual, 819-1157. Integrated Lights Out Manager Administration Guide, 819-1160. Sun Fire X4100 and X4200 Diagnostics Guide, 819-3284. Sun Fire X4100 and X4200 Product Notes, 819-5038. Integrated Lights Out Manager Administration Guide, 820-0280. Sun Fire X4100 and X4200 Integrated Lights Out Manager Supplement, 819-5464. 
 |