CPU/Memory Mezzanine Assembly
Disk Arrays: |
Storage 7410, 7410 SAS 2.0 |
Servers: |
Sun Fire X4440 |
Options X6314A / X6315A / X6317A / X6338A / X6339A / X6342A
501-7723 |
540-7597 |
Mezzanine Board January 2008 L |
Assembly/FRU Air Duct 330-4622
Mezzanine 501-7723 Tray 541-2769
HyperTransport (HT) 2.0 L |
511-1395 |
540-7953 |
Mezzanine Board April 2009 L |
Assembly/FRU Air Duct 330-4622
Mezzanine 511-1395 Tray 541-2769
HyperTransport (HT) 3.0 L |
Sun Fire X4440 Codename: Tucana |
Mezzanine Notes
- Three 541-2906 HyperTransport Risers are required on the System Board.
- Replace Air Duct 330-4433 with Air Duct 330-4644 when the Mezzanine is used.
- The Mezzanine FRU includes Air Duct 330-4622,
Tray 541-2769,
two 250-1802 Cleaning Wipes, and
two 310-0065 Shin-Etsu X23-7783D Thermal Grease Syringes.
- The Mezzanine FRU is not labeled with the FRU part number.
- 501-7723 / 540-7597 only supports HyperTransport Version 2.0.
511-1395 includes capacitor changes to support HyperTransport Version 3.0.
Options X6314A, X6315A, X6317A, and X6342A Notes
- Heatsink 310-0128 includes two Screws and two Springs with no part numbers.
- Heatsink 310-0128 is pre-greased with Shin-Etsu G751.
Option X6338A and X6339A Notes
- Heatsink 310-0180 includes two Screws and two Springs with no part numbers.
- Heatsink 310-0180 is pre-greased with Shin-Etsu X23-7783D.
Memory Notes
- Install memory in matched pairs.
- Memory FRUs include two matched DIMMs.
- Install Memory Filler 371-3651 in all unused slots.
- DIMMs are labeled with the manufacturing part number.
- DIMMs are not labeled with the FRU part number.
References
-
Sun Fire X4140, X4240, and X4440 Installation Guide, 820-2394.
-
Sun Fire X4140, X4240, and X4440 Product Notes, 820-2396.
-
Sun Fire X4140, X4240, and X4440 Diagnostics Guide, 820-3067.
-
Sun Fire X4440 Service Manual, 820-3836.
|