| Disk Arrays: | Storage 7210 |  
| Servers: | Sun Fire X4540 |  
 
| 501-7818 | 541-0491 | 541-3758 |  
| CPU/Memory Board w/o CPU or Memory
 L
 | System Controller FRU CPU/Memory + I/O
 w/o CPU or Memory
 L
 | System Controller FRU CPU/Memory + I/O
 w/o CPU or Memory
 L
 |  
| 541-1219 | 541-3241 |  
| 32GB System Controller 2x Opteron 2356
 16x 2GB 371-1338
 L
 | 64GB System Controller 2x Opteron 2356
 16x 4GB 371-2956
 L
 |  
| 541-3750 | 541-3751 |  
| 32GB System Controller 2x Opteron 2384
 16x 2GB 371-4180
 L
 X4540 only
 | 64GB System Controller 2x Opteron 2384
 16x 4GB 371-2956
 L
 X4540 only
 |   
 
 
| Sun Fire X4540 Codename: Thor Storage 7210 Codename: Fugu
 |  Notes
The minimum Solaris operating system is Solaris 10 5/08.
DIMM pairs require matching characteristics including manufacturer, size,
    and speed.
Replace faulty DIMMs as a pair. The DIMM FRU includes two matching DIMMs.
Fault Remind Button SW1 lights the CPU/Memory fault LEDs for up to
    one minute.
 X4540 Notes
F541-0491 and F541-3758 do not include Heatsinks or Processors.
F541-0491 and F541-3758 include one Alcohol Wipe and
    one 310-0049 Thermal Grease Syringe.
Assembly 541-0491 only supports Opteron 2356 (Barcelona).
Assembly 541-0491 does not support Opteron 2384 (Shanghai).
Assembly 541-3758 supports Opteron 2356 (Barcelona) and 2384 (Shanghai).
Assembly 541-3758 includes I/O Board 501-7819-07 with BIOS and ILOM changes
    required to support Opteron 2384 (Shanghai).
   (WO_40451)
Assembly 541-3758 includes CPU/Memory Board 501-7818-04 with capacitor
    changes required to support Opteron 2384 (Shanghai).
   (WO_40146)
Compact Flash Filler 343-1135 was added to the System Controller in
    August 2010 to reduce radiated emissions.
   (WO_43587)
 7210 Notes
F541-0491 does not include Heatsinks or Processors.
F541-0491 includes one Alcohol Wipe and one 310-0049 Thermal Grease Syringe.
Assembly 541-0491 only supports Opteron 2356 (Barcelona).
Assembly 541-0491 does not support Opteron 2384 (Shanghai).
 References
 Sun Fire X4500/X4540 Server Service Manual, 819-4359. Sun Fire X4500/X4540 Server Administration Guide, 819-6562. Sun Fire X4500/X4540 Server Installation Guide, 820-4855. Sun Fire X4540 Server Product Notes, 820-4869. Sun Fire X4500/X4540 Server Integrated Lights Out Manager (ILOM) Supplement, 819-4361. Sun Fire X4500-to-X4540 Migration User's Guide, 820-6559. Sun Storage 7210 Unified Storage System Installation Guide, 820-3757. Sun Storage 7210 Unified Storage System Service Manual, 820-4160. 
 |