Servers: |
Sun Fire X4600, X4600 M2 |
501-7588 |
501-7638 |
FAB 270-7047 X4600 L |
FAB 270-7047 X4600 M2 L |
Jumpers
LOCATION |
PINS |
SETTING |
DESCRIPTION |
J32 |
1-2 |
Out |
Interlock Switch Disable (default) |
P19 |
1-2 |
Out |
Force BIOS Recovery (default) |
P20 |
1-2 |
Out |
Clear Password (default) |
P21 |
1-2 |
Out |
Hard Reset (default) |
P23 |
1-2 |
Out |
Kill Switch Disable (default) |
P25 |
1-2 |
Out |
Clear CMOS (default) |
P3 |
1-3 |
Out |
Unknown (default) |
Switches
LOCATION |
DESCRIPTION |
SW1 |
Locate Button |
SW2 |
Reset Button |
SW3 |
Non Maskable Interrupt Dump Button |
SW4 |
Top Cover Interlock Switch |
LEDs
LOCATION |
DESCRIPTION |
CR41 CR19 CR34 CR35 CR21 |
-12V Power OK
+5V Power OK
+12V Power OK
+3.3V Power OK
+3.3V Aux Power OK |
CR28 |
DVD Activity |
CR7 CR9 CR10 CR11 CR31 CR8 CR6 CR29 CR30 |
SAS1064 Heartbeat
SAS1064 Fault 0
SAS1064 Fault 1
SAS1064 Fault 2
SAS1064 Fault 3
SAS1064 Activity 0
SAS1064 Activity 1
SAS1064 Activity 2
SAS1064 Activity 3 |
Component Locations
LOCATION |
DESCRIPTION |
J2 |
100MHZ PCI-X Slot 0 (Silkscreened PCIX Slot 1) |
J1 |
100MHZ PCI-X Slot 1 (Silkscreened PCIX Slot 2) |
J3 |
8-Lane PCI Express Slot 2 (Silkscreened PCIE Slot 3) |
J4 |
8-Lane PCI Express Slot 3 (Silkscreened PCIE Slot 4) |
J5 |
4-Lane PCI Express Slot 4 (Silkscreened PCIE Slot 5) |
J6 |
8-Lane PCI Express Slot 5 (Silkscreened PCIE Slot 6) |
J7 |
8-Lane PCI Express Slot 6 (Silkscreened PCIE Slot 7) |
J8 |
4-Lane PCI Express Slot 7 (Silkscreened PCIE Slot 8) |
U1 |
Dual Port Ethernet Controller 0 |
U3 |
525-2247 BIOS |
U4 |
Super I/O |
U9 |
AMD 8132 PCI-X Hypertransport Tunnel |
U11 |
nVIDIA nForce 2200 PCI Express Southbridge |
U21 |
Dual Port Ethernet Controller 1 |
U25 |
LSI SAS1064 |
U27 |
LSI SAS1064 NVSRAM |
U39 |
ATI Rage XL |
U40 |
Graphics Controller SDRAM |
U65 |
nVIDIA nForce 2050 PCI Express Bridge |
U67 |
525-2245 CPLD Firmware |
U74 |
525-2249 SAS1064 Firmware |
XB2 |
CR2032 Battery |
Sun Fire X4600 Codename: Galaxy 4U
Sun Fire X4600 M2 Codename: Galaxy 4F |
Notes
- The minimum Solaris operating system is Solaris 10 01/06 x64.
- Mixing CPU speeds or mixing single-core and dual-core CPUs is not supported.
- The SAS1064 shares the 100MHz PCI-X bus with PCI-X Slots 0 and 1.
Installing 33MHz or 66MHz cards slows the bus and may affect internal
disk performance.
Motherboard Notes
- Motherboard 501-7588 includes X4600 BIOS supporting Opteron 880 and 885.
- Motherboard 501-7638 includes X4600 M2 BIOS supporting Opteron 8000 Series.
- Motherboards 501-7588 and 501-7638 support X4600 BIOS or X4600 M2 BIOS.
- BIOS downloads are available at
X4600 SW 1.5 and
X4600 M2 Firmware Downloads.
CPU/Memory Module Installation Notes
- Two modules (X4600 M2 only):
Install in A and B. All other slots are empty.
Slot A is CPU 0 and B is CPU 1.
- Four modules:
Install in A, D, E, and H. Install a CPU Filler board in all
other slots.
Slot A is CPU 0, D is CPU 1, E is CPU 2, and H is CPU 3.
- Six modules (X4600 M2 only):
Install in A, B, D, E, F, and H. Install a CPU Filler board in
all other slots.
Slot A is CPU 0, B is CPU 1, D is CPU 2, E is CPU 3, F is CPU 4, and
H is CPU 5.
- Eight modules:
Install in A, B, C, D, E, F, G, and H.
Slot A is CPU 0, B is CPU 2, C is CPU 1, D is CPU 3, E is CPU 4,
F is CPU 5, G is CPU 6, and H is CPU 7.
References
-
Integrated Lights-Out Manager Administration Guide for ILOM 1.0, 819-1160.
-
Integrated Lights-Out Manager Administration Guide for ILOM 1.1.1, 820-0280.
-
Sun Fire X4600 and X4600 M2 Servers Installation Guide, 819-4341.
-
Sun Fire X4600 and X4600 M2 Servers Service Manual, 819-4342.
-
Sun Fire X4600 and X4600 M2 Servers Diagnostics Guide, 819-4343.
-
Sun Fire X4600 Server Product Notes, 819-4347.
-
Sun Fire X4600 M2 Server Product Notes, 819-5032.
-
Sun Fire X4600 to Sun Fire X4600 M2 Server Migration, 819-5040.
-
Integrated Lights Out Manager for Sun Fire X4600 and X4600 M2 Servers, 819-5432.
|